Page 387

Instrument Menu

14.7

14

Remote Controller From the main menu, select Instrument / Remote controller. This gives you access to Trimble’s Remote Controller software functionality using the Trimble Survey Controller software. You can use it to view and set values in the receiver, such as NMEA output. The Remote Controller function is based on the front panel of a Series 4000™ receiver. Figure 14.4 shows the first screen that appears.

Figure 14.4

Remote controller screen a b c g0h m9 n

In the Trimble Survey Controller software, the softkeys correspond to menu items. The hard keys , , , , , , and correspond to the menus. Use the hard keys to to enter alphanumeric characters.

Ý to return to the previous menu and press Press the Trimble Survey Controller software.

C

= to return to

Warning – When you use the Remote Controller function in the Trimble Survey Controller software, you can make settings in the receiver that can affect the current survey. In some cases data can be lost.

Trimble Survey Controller Reference Manual Volume 2

355

Page 388

14

14.8

Instrument Menu

Navigate to Point It is not essential to have a radio link or a survey running to navigate to a point. If there is no radio link, all positions are autonomous. If radio corrections are received but the receiver is not initialized, all positions are Float solutions. If you are using a GPS receiver that can track WAAS signals, when the radio link is down you can use WAAS positions instead of autonomous positions. To use WAAS positions, set the WAAS field in the Survey Style to On. Note – If you use the Navigate to point function with an external display, the Trimble Survey Controller software uses the same Survey Style settings used in the previous survey. The display does not work if that survey used a Survey Style - such as FastStatic - that has no External display (NMEA output) options. For the display to work, the Enabled field in the External display (NMEA output) option must be set to Yes. Access this field in the Stakeout option for the Survey Style you are using, or in the Options screen when navigating to the point. To navigate to a point:

35 6

1.

From the main menu, select Instrument / Navigate to point.

2.

In the Point name field, enter the name of the point that you want to navigate to.

3.

Set the Navigate field. The options are To the point, From fixed point, and From start position. The From fixed point and From start position options both provide cross-track information in the graphical screen display. For more information about these see, page 402.

4.

. The Enter a value in the Antenna height field and press stakeout graphical screen display appears. The coordinate differences are displayed, together with a graphical representation of this.

Trimble Survey Controller Reference Manual Volume 2 x

Page 389

Instrument Menu

14

Figure 14.5 shows two screens with different display configurations: –

In the left screen, the Display grid deltas field in the Options screen is set to No.

–

In the right screen, the Display grid deltas field is set to Yes.

Figure 14.5

5.

Grid deltas – not displayed, displayed

Use the graphical display or the text display to navigate to the point.

To use the arrow as a guide, start moving. Hold the TSC1 data collector in front of you as normal. The arrow points in the direction of the point to be staked out. Walk forwards towards the point. The direction arrow only works correctly when you are moving forwards and holding the TSC1 data collector in front of you. In a real-time survey, the display updates one position per second or five positions per second, depending on the equipment used (see Fine and Coarse Modes, page 399). If you are not sure how to use the arrow, use the text side of the display to locate the point.

Trimble Survey Controller Reference Manual Volume 2

357

Page 390

14

Instrument Menu

About three meters (or ten feet) from the point, the arrow disappears and the point is shown as a bull’s-eye symbol. Your current position is shown as a cross. See Figure 14.6. When these two symbols coincide, check the precisions and mark the point if required.

Figure 14.6

Navigate to point graphical display

When the screen display changes from an arrow to a bull’s-eye and a cross, the orientation of the display is fixed.

14.9

Station Setup Details If the TSC1 data collector is connected to a conventional instrument, select Instrument / Station setup details to view the instrument type and current station setup information.

35 8

Trimble Survey Controller Reference Manual Volume 2

Page 391

Instrument Menu

14

Instrument Controls

14.10

If the TSC1 data collector is connected to a servo or robotic conventional instrument, the Instrument controls option appears. Use this option to control the movement of the instrument. Figure 14.7 shows the screen that appears:

Figure 14.7

Instrument controls screen

If you are using a robotic instrument, you can use the TSC1 data collector to operate the instrument remotely through radio communication. This allows the TSC1 data collector to guide the instrument to measure or stakeout points from the target (prism).

14.10.1

Turning the Instrument Choose one of the following methods to turn the instrument: •

HA & VA

•

Point name

HA & VA Use this option to turn the instrument to a specified angle. Do one of the following: •

ã

Enter the horizontal angle in the Turn to HA field to turn the . instrument to a horizontal angle only, and press

Trimble Survey Controller Reference Manual Volume 2

359

Page 392

14

Instrument Menu

•

ã

Enter the horizontal angle in the Turn to HA field and the vertical angle in the Turn to VA field to turn the instrument to a horizontal and vertical angle, and press .

The instrument turns to the angle(s) you entered. Point Name

Use this option to turn the instrument to a specified point. •

Enter a point name in the Point name field and press

The instrument turns to the point you entered.

14.10.2

ã

.

ç

Changing the Face

To switch between Face 1 and Face 2 (direct and reverse) of the instrument, press . The message Please wait. Instrument Turning appears and the instrument turns to the opposite face.

14.10.3

è

Locating and Locking on to the Target The softkey appears in the Instrument controls screen when you operate the instrument remotely from the target (prism). Use the softkey to turn the instrument towards the target when lock has been lost.

36 0

Trimble Survey Controller Reference Manual Volume 2

Page 393

Instrument Menu

è

14

To turn the instrument towards the target: 1.

. The Joystick Mode screen appears, as shown in Press Figure 14.8.

Figure 14.8

2.

Joystick mode screen

*() _

Press , , , or on the arrow keypad of the TSC1 data collector to select a direction to turn the instrument. The instrument will turn in the direction indicated by the solid/filled arrow, as shown in Figure 14.9.

Figure 14.9

Joystick mode screen–direction of instrument turning

Note – When the instrument is on Face 2, the up and down arrows are reversed. For example, if you press , the instrument will turn in an upwards direction. If you press , the instrument will turn in a downwards direction.

) _

Trimble Survey Controller Reference Manual Volume 2

361

Page 394

14

Instrument Menu

3.

Select the same direction to increase the instrument turning speed. The second directional arrow will become solid. Select the same arrow to decrease the speed again.

4.

or another arrow to stop the instrument from turning. Press The directional arrows will become hollow.

=

The instrument is now pointing towards the target.

æ

To make the instrument locate and lock on to the target: •

Press

.

The message Searching... appears on the screen and the instrument starts searching for the target. The results of the search are indicated by the following status line messages: •

Target Locked–indicates that the target has been located and tracking locked. •

Target Detected–indicates that the target has been located (when the instrument is in servo mode). •

14.11

No Target–indicates that the target was not located.

Target If the TSC1 data collector is connected to a conventional instrument, select Instrument / Target to view the target height and the prism constant currently in use.

36 2

Trimble Survey Controller Reference Manual Volume 2