Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 41 of 83

Trimble Survey Controller Reference Manual: Starting the Rover Receiver, pages 347 to 356

Pages 347 to 356 of 744, from Trimble Survey Controller Reference Manual

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSC1

Page 347

Starting the Rover Receiver

C

12.4

12

Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.

3.

Connect the power source to the GPS receiver port 2 and turn on the receiver.

4.

Connect the TSC1 data collector to the GPS receiver port 1. Use the 0-shell Lemo to 0-shell Lemo cable.

5.

Turn on the TSC1 and go to Starting a Rover Survey, page 315.

Setting Up the Equipment for a Real-Time and Postprocessed Survey A Survey Style such as RTK & infill uses both real-time and postprocessed techniques. To conduct such a survey, assemble the rover exactly as for a real-time survey. If the receiver has no memory (or limited memory), leave the TSC1 connected to the base receiver for the purpose of data storage. A second TSC1 is required for the rover receiver.

12.5

Starting a Rover Survey Only start a survey once you have started the base receiver (see Chapter 11, Starting the Base Receiver). To conduct a survey: 1.

Make sure that the required job is open. The title of the main menu should be the current job name.

2.

From the main menu, choose Survey. Select a Survey Style from the list. This must be the same Survey Style used for the base survey.

Trimble Survey Controller Reference Manual Volume 2

315

Page 348

12

Starting the Rover Receiver

A Survey menu is generated. It displays items specific to the chosen Survey Style and includes the Start base receiver and Start survey items. When you start a survey using a particular Trimble Survey Style for the first time, the Trimble Survey Controller software prompts you to customize the Style for your specific hardware. For more information, see Using the Style Wizard to Customize a Trimble GPS Survey Style, page 119. When the survey starts, the menu items Start base receiver and Start survey no longer appear. For kinematic surveys, a new item, Initialization, appears. GPS Total Station 4800 or 4700 receiver If the TSC1 is connected to a GPS Total Station 4800 or 4700 receiver that was logging data, the data logging is stopped. Data logging is restarted, in a different file, if you start a survey using a Survey Style that specifies data logging. Note – When you start a survey, the Trimble Survey Controller software automatically negotiates the highest possible baud rate for communicating with the connected receiver.

12.5.1

Starting a Real-Time Rover Survey To start the rover receiver for a real-time survey: 1.

Select Start survey.

2.

Make sure the rover is receiving radio corrections from the base. Note – An RTK survey needs radio corrections.

31 6

Trimble Survey Controller Reference Manual Volume 2

Page 349

Starting the Rover Receiver

3.

12

If the receiver you are using supports transmission delays and the Prompt for station index field in the Rover options option in the Survey Style is set to Yes, the Select base station screen appears. It shows all the base stations operating on the frequency you are using. The list shows the station index numbers of each base and the reliability of each. Highlight the base you want to use and press .

\

For more information about using transmission delays, see Operating Several Base Stations on One Radio Frequency, page 290.

B

Tip – If you want to check the point name of the base station being used in the rover survey, select Files / Review current job and inspect the Base point record.

4.

If necessary, initialize the survey. For a differential survey, no initialization is necessary, and you can start to survey immediately. (See Chapter 15, Point Measurement Methods.) Note – If you are doing an RTK survey but do not require centimeter-level results, select Survey/Initialization. Press and set the Method field to No initialization.

I

For an RTK survey, initialize before starting centimeter-level surveying: –

If you are using a dual-frequency receiver with the OTF option, the survey automatically starts to initialize using the OTF initialization method.

–

If the OTF option is not installed, or if the receiver is a single-frequency receiver, the Trimble Survey Controller software enters the Initialization screen. Initialize the survey using one of the available methods - Known Point, Initializer Bar/Plate, or New Point. See RTK Initialization Methods, page 321.

Trimble Survey Controller Reference Manual Volume 2

317

Page 350

12

Starting the Rover Receiver

5.

12.5.2

When the survey is initialized you can perform a site calibration, measure points, or stake out.

Starting an RTK & Infill Rover Survey To start the rover receiver for an RTK & infill survey: Note – If you are using postprocessed techniques, to process the data you must have the baseline processing module of the Trimble Geomatics Office™ software installed. 1.

Select Start Survey.

2.

Make sure the rover is receiving radio corrections from the base. Note – An RTK survey needs radio corrections.

3.

If the receiver you are using supports transmission delays and the Prompt for station index field in the Rover options option in the Survey Style is set to Yes, the Select base station screen appears. It shows all the base stations operating on the frequency you are using. The list shows the station index numbers of each base and the reliability of each. Highlight the . base you want to use and press

\

For more information about using transmission delays, see Operating Several Base Stations on One Radio Frequency, page 290.

B

31 8

Tip – If you want to check the point name of the base station being used in the rover survey, select Files / Review current job and inspect the Base point record.

4.

Initialize the survey using an RTK initialization method. For more information, see page 321.

5.

Measure points as usual.

Trimble Survey Controller Reference Manual Volume 2

Page 351

Starting the Rover Receiver

12

Switching to PP infill During periods when no base corrections are received, the following message flashes in the status line: Radio link down

To continue surveying select Start PP infill from the Survey menu. When postprocessing infill starts, this item changes to Stop PP infill. Raw data is logged at the rover during postprocessing (PP) infill. For successful baseline resolution, you must now use postprocessed kinematic observation techniques. Note – Initialization cannot be transferred between the RTK survey and the PP infill survey. Initialize the PP infill survey like any other postprocessed kinematic survey. See Postprocessed Initialization Methods, page 329. Only rely on the OTF (automatic) initialization if certain that the receiver will observe at least five satellites, without interruption, for the next fifteen minutes. Otherwise select Initialization from the Survey menu and perform an initialization. Note – You cannot stake out points during a postprocessed survey. When base corrections are received again, one of the following messages appears in the status line: Radio link up (RTK=Fixed) Radio link up (RTK=Float)

Which message appears depends on the initialization mode of the RTK survey. The first message is displayed if the receiver has retained the RTK initialization during the PP infill survey - it does this if the number of satellites does not fall below four throughout the PP infill survey. Select Stop PP infill from the Survey menu to stop data logging at the rover. When postprocessing infill stops, this item changes back to Start PP infill. Real-time measurements are resumed.

Trimble Survey Controller Reference Manual Volume 2

319

Page 352

12 12.5.3

Starting the Rover Receiver

Starting a Postprocessed Rover Survey To start the rover receiver for a postprocessed survey, select Start survey. Note – If using postprocessed techniques, to process the data you must have the baseline processing module of the Trimble Geomatics Office software installed. For a FastStatic or differential survey, initialization is not required and surveying can begin immediately. See Chapter 15, Point Measurement Methods. For a PP kinematic survey, initialization must be gained to achieve centimeter-level precisions when the data is processed: •

With dual-frequency receivers, the initialization process begins automatically if at least five L1/L2 satellites are being observed. The OTF option is not required for this initialization.

•

With a single-frequency receiver, the Initialization screen appears when you select Start Survey. Initialize the survey using one of the available methods: Known Point or New Point.

For more information about initializing a postprocessed survey, see Postprocessed Initialization Methods, page 329. To measure points see Chapter 15, Point Measurement Methods. Working in Float mode

\ I

Work in Float mode if you do not want to initialize a survey. Start the survey and select Initialization. When the Initialization screen . Set the Method field to No initialization and appears, press press .

32 0

Trimble Survey Controller Reference Manual Volume 2

Page 353

Starting the Rover Receiver

12.6

12

RTK Initialization Methods If base corrections are being received and there are four or more satellites, the survey can be initialized. A survey must be initialized before centimeter-level surveying can begin. Use one of the following methods to initialize dual-frequency RTK surveys: •

Known Point

•

New Point

•

Initializer Bar/Plate

If the rover receiver has the On-The-Fly (OTF) option installed, initialization is performed automatically. The New Point method is not available, but you can initialize on a known point. To do this, select . Survey / Initialization and press

I

Note – At least five L1/L2 satellites are required for OTF initialization. After initialization, at least four satellites must be tracked. If the number of satellites drops below four, the survey must be reinitialized. Use one of the following methods to initialize single-frequency RTK surveys: •

Known Point

•

New Point

•

Initializer Bar/Plate

Trimble Survey Controller Reference Manual Volume 2

321

Page 354

12

Starting the Rover Receiver

Table 12.1 summarizes methods of initializing a real-time kinematic survey, and the time required for each method. Table 12.1

Initializing a Real-time kinematic survey Time required for each initialization method

Survey and receiver type

Known Point Initializer Bar/Plate

New Point

OTF

Range (km)

RTK Single-frequency

~15 s (5+ SVs) ~30 s (4 SVs)

~20 m

No

<10

RTK Dual-frequency

~15 s (5+ SVs) ~30 s (4 SVs)

~60 s, 5+ SVs

No

<10

RTK Dual-frequency with OTF

~15 s (5+ SVs) ~30 s (4 SVs)

No

~60 s, 5+ SVs

<10

Note – Initialization must be maintained throughout the survey by continuously tracking a minimum of four satellites. If initialization is lost at any time, reinitialize and then continue the survey. After initialization, the survey mode changes from Float to Fixed. The mode remains Fixed if the receiver continuously tracks at least four satellites. If the mode changes to Float, reinitialize the survey. Multipath Initialization reliability depends on the initialization method used and on whether or not multipath occurred during the initialization phase. Multipath occurs when GPS signals are reflected off objects (such as the ground or a building). The occurrence of multipath at the GPS antenna adversely affects GPS initializations and solutions: •

32 2

If initialization is by the Known Point or Initializer Bar method, multipath can cause an initialization attempt to fail.

Trimble Survey Controller Reference Manual Volume 2

Page 355

Starting the Rover Receiver

•

12

If initialization is by the OTF or New Point method, it is difficult to detect the presence of multipath during the initialization. If there is multipath, the receiver may take a long time to initialize or it may not initialize at all. See Recommended RTK Initialization Procedure, page 328.

The initialization process in Trimble receivers is very reliable but if an incorrect initialization does occur, Trimble’s RTK processing routines detect it within 15 minutes (if the mode has remained Fixed). When the error is detected, the receiver automatically discards the initialization and issues a warning. Note – If you survey points with a bad initialization, position errors result. To minimize the effect of multipath during an OTF initialization, move around.

12.6.1

On-The-Fly (OTF) Initialization If a system has On-The-Fly (OTF) capability, initialization is automatic. Wait for the system to initialize. When the status line shows RTK=Fixed, the survey is initialized and you can start to measure points.

12.6.2

Known Point Initialization To perform a Known Point initialization: 1.

Position the rover antenna over a known point.

2.

From the Survey menu, choose Initialization.

3.

Set the Method field to Known Point and press

4.

Enter a value in the Point name field. (This must be the name of a known point in the Trimble Survey Controller software . database.) While still in the Point name field, press Select the point from the list of known points.

5.

Enter values in the Code and Antenna height fields, and make sure that the setting in the Meas. to field is correct.

\

.

l

Trimble Survey Controller Reference Manual Volume 2

323

Page 356

12

Starting the Rover Receiver

6.

x\

When the antenna is centered and vertical over the point, press or .

The data collector starts to record data, and the static icon (see page 42) appears in the status line.

O n

Keep the antenna vertical and stationary while data is recorded.

12.6.3

7.

When the receiver is initialized, the results are displayed and softkey appears. Press it to accept the initialization. the

8.

If the initialization fails, the results are displayed. The Trimble Survey Controller software asks if you want to retry. Press or .

y

New Point Initialization (No OTF) To perform a New Point intialization: 1.

B

Position the rover antenna a distance away from the base receiver.

Tip – Trimble recommends that you use a bipod attached to the range pole when using this method.

\

2.

From the Survey menu, choose Initialization.

3.

Set the Method field to New Point and press

4.

Enter values for the Point name, Code, and Antenna height fields.

5.

.

x\

When the antenna is centered and vertical over the point, press or .

The data collector starts to record data, and the static icon appears in the status line.

O

Keep the antenna vertical and stationary while data is recorded. 6.

32 4

When the receiver has initialized, the Press it to store the point.

Trimble Survey Controller Reference Manual Volume 2 softkey appears.