The text of a manual · part 4 of 5

LANpoint CE Installation and Maintenance Manual, pages 28 to 36

Pages 28 to 36 of 45

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Texas Instruments LANpoint CE

Page 28

LANpoint CE Terminal

Open the Start menu. Select Programs, select Windows Explorer. Select and open the Storage Card folder. Select and open the CEFlush.exe program. The CEFlush program runs, writing the changes from the registry to CompactFLASH and shuts down. 9. Restart the LANpoint CE terminal and verify the new settings. a. b. c. d.

5.0.4.1.2 Using the LANpoint CE Monitor Program Refer to the LANpoint CE Developer’s Manual for more information on changing IP addresses using the Monitor program. To obtain a copy of this manual, either download the Acrobat file 855M502 from Intelligent Instrumentation’s web site at www.lanpoint.com, or contact Intelligent Instrumentation Incorporated.

5.0.4.2

Network Servers

To set network adapter settings on the LANpoint CE terminal using Windows CE: 1. Select Start/Settings/Control Panel. 2. Select the Network icon to open the Network Configuration dialog. 3. In the Adapters tabbed dialog, select LAN9000 Compatible Network Adapter from the dropdown list and select the Properties button. The LAN9000 Compatible Network Adapter Settings dialog opens. 4. In the LAN9000 Compatible Network Adapter Settings dialog, the Name Servers tabbed dialog contains fields for the DNS and WINS servers. 5. When you finish making entries in this dialog, click the OK button in the dialog. 6. Save the settings to CompactFLASH: Open the Start menu. Select Programs, select Windows Explorer. Select and open the Storage Card folder. Select and open the CEFlush.exe program. The CEFlush program runs, writing the changes from the registry to CompactFLASH and shuts down. 7. Restart the LANpoint CE terminal and verify the new settings. a. b. c. d.

5.0.5

Adjusting the Display Contrast

You can increase or decrease the contrast on the LANpoint CE terminal’s color or monochrome LCD. The terminal has a contrast application, contrast.exe, located on CompactFLASH. The contrast.exe program maintains a file called contrast.txt on the root of the storage card that is used during power-up to establish the initial contrast display.

20

Page 29

LANpoint CE Terminal

There are several methods that you can use to adjust the display contrast: command line, shortcuts, and programmable function keys. Command Line Using large values for n to increase or decrease contrast can make the display illegible. If this occurs, contact customer support. To increase contrast to lighten the display: In \Start\Run type "\Storage Card\Contrast.exe" +n For the value of n, use small increments such as +2 and view the results. To decrease contrast to darken the display: In \Start\Run type "\Storage Card\Contrast.exe" -n For the value of n, use small increments such as -2 and view the results. Shortcuts Lighten Display shortcut In \Storage Card select and open the Lighten Display shortcut icon. The contrast LCD immediately lightens. Darken Display shortcut In \Storage Card select and open the Darken Display shortcut icon. The contrast LCD immediately darkens. Programmable Function Keys See the LANpoint CE Developer’s Manual for more information on creating PFKs.

5.0.6

Adjusting the Speaker Volume

The speaker volume is controlled by a potentiometer. The LANpoint CE terminal ships from the factory with the speaker volume set to the maximum position. To decrease to volume level: 1. Use proper grounding before handling the CPU board as it contains ESD-sensitive components. 2. Locate potentiometer R1 (near the top of the CPU board below the external VGA connector). 3. Turning the potentiometer R1 clockwise reduces the volume.

21

Page 30

LANpoint CE Terminal

To test the volume level of the speaker disconnect external power and reconnect the power. The terminal emits a double-beep when the terminal powers up.

FIGURE 16 Volume Adjustment

5.0.7

Internal LEDs

Internal LEDs on the CPU board indicate network activity or inactivity. See FIGURE 17, Internal LEDs. Their functions are described in TABLE 1, Internal LED Indicators.

FIGURE 17 Internal LEDs

22

Page 31

LANpoint CE Terminal

LED

Function Description

Function Description

D5

Transmit: Indicates the terminal is transmitting data packets via Ethernet.

Receive: Indicates the terminal is receiving data packets via Ethernet.

D6

Collision: Indicates that data transmitted via Ethernet is colliding with other network traffic.

Speed: Indicates data is being transmitted or received using 10Base T or 100Base T Ethernet connection. LED ON: 100 MB/s using the 100Base T LED OFF: 10 MB/s using the 10Base T

D7

+5V monitor: Verifies there is power to the terminal.

Link: Verifies there is a valid Ethernet connection with another device.

TABLE 1 Internal LED Indicators

6.0

Maintenance

Maintenance of the LANpoint CE terminal includes replacing the real-time clock battery and the optional battery backup pack.

6.0.1

Replacing the Real-time Clock Battery

The real-time clock battery maintains the current date and time. It has a life expectancy of 5 years. To replace the real-time clock battery: 1. Obtain battery replacement part: 3 V lithium CR 2032 2. Follow proper ESD grounding procedures to prevent damage to electronics. 3. Disconnect the external power cable from connector P1 and all cables connected to the power board, including auxiliary power outputs P4 and P5 if they are in use. 4. Access the back of the LANpoint CE terminal. If the optional rear cover is present, remove and save the 4 screws holding the cover on the terminal and remove the cover. 5. If an optional battery backup pack is present, disconnect the optional battery backup pack cable from connector P3. Leaving P3 connected may cause damage to the terminal during reinstallation. 6. Remove the five screws that secure the power board to the CPU board. 7. Carefully remove the power board. 8. Lift the retaining clip holding the existing lithium real-time clock battery and remove the battery from its holder BT1 on the CPU board as shown in FIGURE 18, Real-time Clock Battery.

23

Page 32

LANpoint CE Terminal

9. Insert the new lithium real-time clock battery into the holder (BT1) with the positive + battery terminal side of the battery facing you. Carefully release the retaining clip.

FIGURE 18 Real-time Clock Battery

10. Align the pins on the power board connector with the CPU female header J1. Verify the holes for the screws in the power board align with the stand-offs on the CPU board before fully seating the power board onto the CPU board. 11. Fasten the power board to the CPU board using the five screws removed in step 6 for the stand-offs. 12. Reconnect the battery backup pack cable, if present, to the connector P3. 13. Reinstall the optional rear cover (if present) and fasten the hardware removed in step 4. 14. Reconnect power to the LANpoint CE terminal at P1, and cables to auxiliary power output connectors P4 and P5, if present. 15. Reset the clock in the Microsoft Windows Control Panel in \Start\Settings\Control Panel and select the Date/Time icon. Use the built-in keyboard or an external mouse to reset the clock and click the Apply button. You can also use the Time Synchronization program and Monitor program to reset the clock (see the LANpoint CE Developer’s Manual for more information).

6.0.2

Replacing the Optional Battery Backup Pack

To replace the battery backup pack when it no longer holds a charge, see section 2.0.3.1, Battery Backup Pack for installation instructions.

7.0

Dimensional Drawing for Mounting the Terminal

FIGURE 19, Wall Mount Cutout Dimensions provides metric and English dimensions for mounting the LANpoint CE terminal to a wall. See section 3.0.1, Flush Mount Option for installation instructions.

24

Page 33 read from a scan by OCR; it may hold reading errors

FIGURE 19 Wall Mount Cutout Dimensions

25

NOTES: AX OPTIONAL CUTOUT FOR CABLE ROUTING, 2. DIMENSIONS ARE, INCH [MM]

9.166 [64.22] 17 PLACES

[94661] s9g°4. - - O |

[<Veel] e¢z°-¢> - - O |

[6s'99] 7z7a'~ - - _D

8.720 [221.49] ren, 8.558 [217.37]

6.540 [166.12] @ - - 6.540 [166.13]

4.360 [110.74] 4.360 [110.74]

WALL MOUNT CUTOUT 6.095 [127.64] A FOR LANPOINT CE TERMINAL AY , (FRONT VIEW) 4

3.695 [93.85] 3.695 [93.85]

5.025 [127.64] - [oseoc] erl'zl [ge'68z] s6e'll [rose] 206° [lZ'Zy] 7991

2.180 [55.38] 2.180 [55.37]

181 [4.60] ,000 [0,00]

181 [4.60] ao Awe

G} pA |

| sss) Bel

@ - [tr'6o] SSL [ooo] ooo"

| tes 9s] 66o'E O - [vr6'8z] 801s

O - [LV'Z41] 62'S ~ - Lro-eet] 29's

@ - - [+4902] ovis

[ye'99z] 98r'OL [y8'79Z] Bre'OL

LANpoint CE Terminal

Page 34

LANpoint CE Terminal

26

Page 35

Connector Diagrams

Appendix A

A.1 Connector Pinout Diagrams This appendix contains information for wiring the following: Ethernet

External Mouse

COM1 and COM2

External Keyboard

Bar Code

Auxiliary Power Output

Laser

External Power Input

Slot Reader

External VGA Monitor

A.1.1

Ethernet

The LANpoint CE terminal has one Ethernet 10/100 Base-T Connector shown in FIGURE A-1, Ethernet 10/100 Base-T connector located on the back of the terminal in the lower left-hand corner.

FIGURE A-1 Ethernet 10/100 Base-T connector

Ethernet 10/100 Base-T connector Pin Number

Function

1

TX+

2

TX-

3

RX+

4, 5, 7, 8

Not used

6

RX-

A-1

Page 36

Connector Diagrams

A.1.2

COM1 and COM2 Ports

The LANpoint CE terminal has two COM ports located on the back of the terminal as shown in FIGURE A-2, COM1 and COM2 Ports.

FIGURE A-2 COM1 and COM2 Ports

A-2

COM1 RS-232 DB9- pin connector P3

COM2 RS-232 DB9- pin connector P8

Pin Number

Function

Pin Number

Function

1

DCD

1

DCD

2

RX

2

RX

3

TX

3

TX

4

DTR

4

DTR

5

GND

5

GND

6

DSR

6

DSR

7

RTS

7

RTS

8

CTS

8

CTS

9

RI

9

RI