Page 11
Items b, c, and d are indicated on the label. The REN is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly. 5. In the event of equipment malfunction, all repairs should be performed by our Company or an authorized agent. It is the responsibility of users requiring service to report the need for service to our Company or to one of our authorized agents. Service information can be obtained at: Telxon Corporation 3330 West Market Street Akron, OH 44334-0582 6. If, through abnormal circumstances, harm to the telephone lines is caused, the device should be unplugged until you determine if your device or the telephone is the source; it should not be reconnected until necessary repairs are effected. 7. Should the telephone company notify you that your device is causing harm, the device should be unplugged. The telephone company will, where practicable, notify you that temporary discontinuance of service may be required. However, where prior notice is not practicable, the telephone company may temporarily discontinue service, if such action is reasonably necessary. In such cases, the telephone company must a. promptly notify you of such temporary discontinuance, b. afford you the opportunity to correct the condition, and c.
inform you of your rights to bring a complaint to the FCC under their rules.
9
Page 12
8. The telephone company may make changes in its communications facilities, equipment, operations, or procedures, where such action is reasonably required in the operation of its business and is not inconsistent with FCC rules. If such changes can be reasonably expected to render any customer’s devices incompatible with telephone company facilities, or require modification or alteration, or otherwise materially affect their performance, written notification must be given to the user to allow uninterrupted service.
DOC statement Notice: The Canadian Department of Communications (DOC) label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by Telxon. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
10
Page 13
! Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority, or electrician, as appropriate.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. The load number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop, which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the load numbers of all the devices does not exceed 100. An alphabetic suffix is also specified in the load number for the appropriate ringing type (A or B), if applicable. For example, LN = 20 A designates a load number of 20 and an “A” type ringer.
11
Page 14
Safety information
2
Disposing of nickel-cadmium batteries The nickel-cadmium batteries that are recharged by the SC-960RL/SC-960L contain chemically active materials that are hazardous to the environment; therefore, they must be disposed of properly. Never attempt to incinerate a nickel-cadmium battery; doing so could cause it to explode. Telxon urges you to contact the Environmental Protection Agency, the Department of Natural Resources, a local hazardous waste disposal agency, or the Telxon Customer Support Center for assistance prior to disposing of your nickel-cadmium batteries.
12
Page 15
Scope of the manual
3
This manual provides general information on how to install, operate, and maintain the SC-960RL and SC-960L Single-bay Communication Cradles. Use this manual as an introduction to your cradle along with the manual or instructions provided by your supervisor. This manual does not provide instructions on how to perform the tasks specific to your job in your organization. For that information, refer to the manual or instructions provided by your supervisor.
Document conventions The following conventions are used throughout this manual.
Cautions Cautions indicate potential damage to equipment. They are set off in the left-hand columns of this manual by the following symbol: !.
Notes Notes provide supplementary information. They are set off in the left-hand columns of this manual and are not preceded by a symbol.
13
Page 16
Overview of the SC-960RL/SC-960L
4
The SC-960RL and SC-960L Single-bay Communication Cradles are accessories for the PTC-960RL and PTC-960L, respectively. The cradles work with the PTCs in two ways. First, the cradle acts as a communication link between the PTC and a host computer. It can send data to and receive data from both units. The PTC and the cradle communicate with each other through their optical couplers and with the host computer via a cable or modem. Second, the cradle automatically charges a PTC’s nickel-cadmium battery pack and a spare battery pack when the PTC and spare pack are inserted into the cradle. It requires approximately 12 hours to charge both packs (plus the amount of time the PTC spends communicating with a host computer). Light-emitting diodes (LEDs) on the cradle’s front panel indicate power, communication, and battery charging status. A modem is an electronic device that allows the cradle to send and receive signals over standard telephone lines.
The SC-960RL/SC-960L can be equipped with one of six country-specific internal modems that provides one-way or two-way communication. The cradle can also be connected to an external modem. See Appendix A for more information about modem options. The cradle can be used by itself or can be connected directly to other SC-960RL/SC-960Ls to form a system of up to 32 cradles.
14
Page 17
Getting started
5
Unpacking the SC-960RL/SC-960L Any additional accessories are shipped separately.
See Appendices B and C for cable part numbers and information.
Each shipping box contains • an SC-960RL or an SC-960L,
• a 12-VDC, 800-mA power pack,
• a cradle base (if your cradle was ordered as a table-top version),
• an SC-960RL/SC-960L Read-Me-First Sheet, and
• an SC-960RL/SC-960L User’s Guide.
If you will be connecting the cradle to a host computer, you need a properly wired cradle-to-host cable, available separately. 1. Remove the cradle from the box. 2. Remove all packing material from the cradle. Save the packaging in case the cradle is ever stored or shipped to Telxon for service. 3. Check the contents of the package to make sure you have received everything ordered.
If anything is missing or damaged, notify your Telxon sales representative.
4. Check the cradle and accessories for shipping damage.
15
Page 18
Parts
6
Figures 1 and 2 on pages 17 and 18 show and describe the parts of the SC-960RL/SC-960L. The parts listed below are not shown in either figure.
Cradle base A cradle base is shipped with every table-top version of the SC-960RL or SC-960L. The base holds the cradle in place on a flat horizontal surface. It can be permanently mounted through its four mounting holes.
Modem module (optional) See Appendix A for a list of available modem modules. See page 23 for information on connecting the internal modem to telephone lines.
The SC-960RL/SC-960L can be equipped with an internal modem module that provides communication capability over standard telephone lines between a PTC installed in the cradle and a host computer. Either one-way half-duplex or two-way full-duplex communication is available.
Power pack The power pack, which provides power to the cradle, plugs into the cradle’s power connector and into an electrical outlet (110 volts AC in the U.S. or Canada). It provides 12 volts of direct current (VDC) at 800 milliamperes (mA). Each cradle, whether installed individually or as part of a system of connected cradles, must have its own power pack.
16
Page 19
Figure 1. The SC-960RL/SC-960L (front view)
1. PTC bay
6. Optical coupler (in bottom of PTC bay)
2. Spare battery bay 5. Daisychain connector 3. Host connector
4. LEDs
1. This area of the cradle holds a PTC-960RL or a PTC-960L. The bay contains the cradle’s optical coupler and battery charging contacts. 2. This area of the cradle holds a spare nickel-cadmium battery pack. The bay contains battery charging contacts. 3. This female 25-pin connector connects via cable to a host computer or external modem. When cradles are connected together, this connector (on all cradles in the system except the one in the left-most position) plugs into the daisychain connector of another SC-960RL/SC-960L. 4. These light-emitting diodes indicate power, communication, and battery charging status. See Appendix D for an explanation of the LEDs. 5. This male 25-pin connector plugs into the host connector of another SC-960RL/SC-960L to form a system of daisychained cradles. You can connect up to 32 cradles in a system. 6. The SC-960RL/SC-960L’s optical coupler provides an optical communication path to and from a PTC residing in the cradle’s PTC bay.
17
Page 20
Figure 2. The SC-960RL/SC-960L (back and bottom view)* 1. Mounting holes
2. Power connector 3. Power pack cable hook (not pictured) 4. RJ-11 jack (optional)
* This view of the SC-960RL/SC-960L shows the cradle in its wall-mount configuration.
1. These mounting holes allow table-top versions of the cradle to be secured in a cradle base and wall-mount versions to be mounted on a wall via a standard telephone wall mounting plate. See Chapter 8 for details. 2. A 12-VDC, 800-mA power pack plugs into this connector and an electrical outlet to supply power to the cradle. 3. Sliding the power pack’s cable under this hook helps to prevent the cable from becoming unplugged. 4. If your SC-960RL/SC-960L was ordered with an internal modem, it will have an RJ-11 jack, a standard modular telephone-type jack. It can be used to connect the cradle directly to a telephone line. If your SC-960RL/SC-960L was not ordered with an internal modem, it can be connected to most standard external modems. You will need to connect a cradle-to-modem cable to the cradle’s host connector and to the connector on the external modem. See Appendix B for cable part numbers.