Page 31
Figure 4. Scanning bar-code labels Scan LED Good Scan LED
Scan button
Make sure the scan line extends beyond both sides of the bar code
Using the PTC’s internal image reader (optional) If your PTC-960LE contains an image reader, the unit can be programmed to automatically decode up to six 1D bar-code types and four 2D bar-code types. See Appendix B for a list of these bar codes and the information provided by your organization for details on how your PTC has been programmed. Use this procedure to decode 1D and 2D bar codes or to capture handwritten signatures with the PTC-960LE’s internal image reader. 1. Point the PTC at the bar code or signature. Your application program may not support scanned data for all fields. Consult the documentation for your application to determine when the reader and Scan button are enabled.
2. Press the PTC’s Scan button to activate the reader. The red Scan LED glows. The bar code or signature must be within the perimeter of the crosshairs emitted from the reader. If the decode/capture is successful, the green Good Scan LED glows, and the PTC beeps.
29
Page 32
Communicating data
9
The PTC-960LE is able to communicate with other PTCs, host computers, and external accessories such as printers, external radios, and modems. It can both send and receive data and instructions. Communication is controlled by your organization’s application program. See the manual or instructions provided by your organization for details on conducting communication sessions. The PTC-960LE is designed to use its internal radio as its primary means of communicating with a host computer, but it can also communicate by being connected directly to the host computer via cable or by being placed in an optical communication cradle that is connected to the host computer. Accessories such as printers, radios, and modems are connected to the PTC with a cable.
Using the radio All radio communication is controlled by your organization’s application program. See the instructions provided with the program for information.
Using the micro DB-15 connector Refer to Appendix C for cable part numbers.
Making a direct connection between the PTC-960LE and another computer or accessory requires a cable with a micro DB-15 connector on one end and a standard RS-232 signal interface on the other. The cable must be ordered separately.
30
Page 33
Connecting a cable 1. Make sure you have the correct cable for the device to which you are connecting. If you use the wrong cable, the PTC may not be able to communicate. 2. Turn off the PTC and the computer or accessory to which you are connecting. 3. Loosen the cable’s jack screws, if present. ! Do not force any connectors together if they do not mate easily; you could damage them.
4. Gently slip the cable’s micro DB-15 connector into the PTC’s micro DB-15 connector. 5. Connect the other end of the cable to the computer or accessory. Make sure the connectors line up correctly. 6. Tighten the cable’s jack screws, if present. 7. Turn on the PTC and then turn on the device it is connected to. 8. Follow the instructions for your application program to communicate.
Disconnecting a cable Always disconnect connectors by pulling them directly away from each other. Do not pull at an angle or use a rocking or twisting motion. 1. Turn off the PTC. 2. Turn off the device the PTC is connected to. 3. Loosen the cable’s jack screws, if present. ! Pull on the cable connector when disconnecting. Pulling on the cable can break the internal wires.
4. Pull the cable’s connector directly away from the PTC’s micro DB-15 connector. 5. If necessary, disconnect the other end of the cable from the computer or accessory.
31
Page 34
Using an optical communication cradle Refer to the SC-960LE/WM-960LE User’s Guide or the VC-960LE User’s Guide for instructions on using the PTC-960LE with the cradle.
The PTC-960LE’s optical interface converts electronic signals inside the PTC into pulses of light that can be detected by the SC-960LE Single-bay Communication Cradle, the WM-960LE Wall-mount Communication Cradle, or the VC-960LE Vehicle Cradle. When the PTC-960LE is placed in the cradle, an optical interface on the cradle senses the pulses of light from the PTC and converts them into electronic signals for direct communication to the host computer or an external peripheral. Likewise, the cradle can communicate back to the PTC through the optical interfaces.
32
Page 35
Replacing the battery pack ! Do not leave the PTC without a battery pack for longer than 20 minutes; all data and programs in the PTC’s memory will be lost.
10
Use the procedures in this chapter to remove a weak lithium-ion or nickel-cadmium battery pack from the PTC-960LE and replace it with a new one. The Low Battery icon appears on the PTC’s display when the battery pack is running out of power.
Removing the battery pack 1. Turn off the PTC. 2. Place the unit face down. 3. Grasp the bottom of the handstrap and pull it away from the PTC until it disengages. 4. Lift up the handstrap to expose the battery pack latch. 5. Slide the latch toward the top of the unit; then grasp the battery pack and remove it from the PTC. 6. Refer to the “Safety information” section on page 11 for instructions on properly disposing of your lithium-ion or nickel-cadmium battery pack.
Installing a new battery pack 1. Make sure the PTC is off. 2. Hold the new battery pack over the battery compartment, making sure the Telxon label is facing down and the tab is pointing toward the bottom of the PTC.
33
Page 36
3. Insert the battery pack’s tab into the slot in the bottom of the battery compartment. 4. Slide the battery pack latch toward the top of the unit; then lower the battery pack into the compartment. 5. Slide the battery pack latch toward the bottom of the PTC until it will go no farther. 6. Reconnect the handstrap to the bottom of the PTC by stretching the strap past the PTC’s optical interface and inserting the handstrap bracket into the slots provided.
34
Page 37
Maintaining the PTC-960LE
11
Operating conditions The PTC’s display screen will be slower and darker if the unit is operated at lower temperatures.
The PTC-960LE is designed to minimize the intrusion of dust, dirt, and moisture. An optional holster, listed in Appendix C, is recommended when using the PTC in exceptionally harsh environments. Units containing a frequency-hopping radio can be operated at temperatures between 32 degrees F (0 degrees C) and 120 degrees F (49 degrees C); units without a frequencyhopping radio can be operated in temperatures as low as –4 degrees F (–20 degrees C).
Handling the PTC The following information will help to ensure you receive safe, reliable, and trouble-free service from your PTC-960LE. •
Do not stare into the laser beam or point the PTC’s scanner at anyone’s eyes. You could cause permanent eye damage.
•
Do not open the PTC’s case. Only a trained technician can service the parts inside the PTC.
•
Make sure the PTC is off before you connect or remove any cables or accessories or replace the battery pack.
•
Make sure all accessories are connected correctly and the correct cables are used.
•
Use only Telxon-approved accessories. Do not attempt to connect any electrical device that is not part of your PTC system to the PTC-960LE.
•
Protect the PTC from excessive heat, cold, moisture, and harsh, dirty environments. 35
Page 38
•
If you store a PTC-960LE containing a lithium-ion or nickel-cadmium battery pack in below-freezing temperatures for more than 1 hour, do not charge the pack until it warms up to room temperature. Charging cold battery packs could damage them.
•
Do not insert anything other than Telxon-approved cables into the PTC’s micro DB-15 connector.
Storing the PTC •
Do not store the PTC-960LE in temperatures below –20 degrees F (–29 degrees C) or above 160 degrees F (71 degrees C).
•
Do not store the PTC-960LE in a damp or humid environment.
1. Transfer any data stored in the PTC to a host computer or another PTC or print the data. See the manual or instructions for your organization’s application program for directions. 2. Make sure you have a copy of any programs stored in the PTC. 3. Disconnect all accessories from the PTC. 4. Recharge the PTC’s battery pack or replace it with a charged pack. 5. Pack the PTC in the original packing material or in a padded box and put it in a safe place, away from dust, dirt, humidity, and excessive cold. 6. Charge the PTC’s battery pack every two months.
Cleaning the PTC ! Be careful not to scratch the scanner lens when you clean it. Scratches can reduce the scanner’s effectiveness.
Equipment required: •
A soft, lint-free cloth
•
A nonabrasive liquid cleaner such as Windex
36
Page 39
! Do not soak the cloth and do not spray or pour cleaning liquids directly onto the PTC.
To clean the PTC, slightly moisten a soft, clean, lint-free cloth with a mild, nonabrasive cleaner and wipe the outside surfaces. Do not use a paper towel. If the PTC becomes extremely dirty or if liquids, dirt, or other foreign materials get inside the case, contact your Telxon service representative.
Servicing the PTC Do not attempt to service the PTC. Only a trained Telxon technician may service the PTC. Follow the procedure set up by your organization to have the PTC serviced properly.
37
Page 40
Troubleshooting
12
If you experience any of the problems listed in this chapter, follow the instructions provided.
The PTC does not turn on •
Charge or replace the PTC’s battery pack.
•
Contact your Telxon service representative.
The laser scanner does not read a label •
Make sure the label you are trying to scan is one of the bar-code types your PTC is programmed to recognize.
•
Move the scanner lens closer to or farther away from the bar-code label. You may not be scanning at the correct distance.
•
Change the angle of the laser scanner to the barcode label. You may be too far above or below the label or too far to the side to scan properly.
•
Clean the scanner lens.
•
The PTC’s application program may not support scanned data at this particular field. Consult the documentation for the PTC’s application program to determine when the scanner and Scan button are enabled.
•
Point the scanner at a blank surface and press the Scan button. Look for the scanning line that appears on the blank surface when the scanner is operating. If no scanning line appears, follow your organization’s procedure to have the scanner serviced.
38