Page 21
Charging the battery pack Charge the PTC-960LE’s lithium-ion or nickelcadmium battery pack when you first receive the PTC and whenever the battery pack becomes weak. A Low Battery icon appears on the PTC’s screen when the battery pack is running out of power. This section explains how to recharge the PTC’s battery pack using an AC adapter. For instructions on charging the battery pack via a communication cradle or a four-bay battery charger, refer to the documentation shipped with the cradle or charger. Equipment required:
To charge the battery pack outside of the U.S. or Canada, you need an AC adapter designed for the country’s AC voltage supply (e.g., 220 volts).
•
A 12-VDC, 200-mA AC adapter
•
An electrical outlet within 6 feet (1.8 meters) providing 110 volts AC in the U.S. or Canada
1. Turn off the PTC and disconnect any attached accessories. 2. Connect the AC adapter’s cable to the PTC’s micro DB-15 connector. 3. Plug the AC adapter into an electrical outlet. The PTC’s Charging LED glows. 4. Charge the battery pack for 8 hours. The Charging LED turns off when the battery pack has reached a full charge. 5. When charging is finished, disconnect the AC adapter from the PTC and the outlet.
Turning on the PTC-960LE The PTC can also be turned on by pressing the Scan button.
1. Press the ON/OFF key to turn on the PTC-960LE.
19
Page 22
Checking the PTC-960LE 1. Make sure the PTC is turned on. 2. Look at the PTC’s display screen. What appears on the screen depends on the program your organization uses. If the PTC is operating correctly, you should not see or hear any of the following:
It may take several seconds for information to appear on the PTC’s display the first time the unit is turned on.
•
A low-battery warning
•
A blank display screen (for longer than 15 seconds)
•
Any warning beeps
Repeat the steps in this section if your PTC-960LE is not operating properly. If the problem persists, refer to the “Troubleshooting” section on page 38.
20
Page 23
Parts
6
Figures 1 through 3 on the following pages show and describe the external parts of the PTC-960LE. The parts listed below are internal and, therefore, are not shown in any of the figures.
Flash EPROM A flash EPROM is an electronic component installed inside the PTC. It contains the PTC’s data collection program and determines the PTC’s key functions, the display prompts and messages, and how and when the PTC prints or transmits data. For details on erasing and reprogramming the PTC’s flash EPROM, refer to the Guide to the Flash Utilities (TCAL or MS-DOS Version).
The flash EPROM can be erased and reprogrammed while it is inside the PTC. First, the PTC must be connected to a host computer, via a cable or by being placed in an optical communication cradle. Then, using software in the PTC’s operating system, you can erase the flash EPROM and reprogram it with a new program from the host computer.
Radio Your PTC’s application program controls the radio. Refer to your application’s manual for details. If your PTC is equipped with an image reader, it cannot contain a radio.
Your PTC-960LE may contain a 900-MHz or 2.4-GHz direct-sequence spread spectrum radio, a 2.4-GHz frequency-hopping spread spectrum radio, or a 2.4-GHz FieldNet 500 radio module. These radios allow the PTC to interactively communicate in real-time with a host computer on a radio-based local area network. They provide secure, interference-free communication and do not require a license for operation.
21
Page 24
Figure 1. The PTC-960LE (front view)
1. Backlight button
4. Scan button
2. Keyboard
3. Micro DB-15 connector 1. The Backlight button turns the screen’s backlight on or off. It can also be used to control screen contrast. See page 27 for instructions. 2. The PTC-960LE’s keyboard has 35 keys. The keyboard has two different types of keys: data keys and function keys. Data keys are the letter and number keys, A-Z and 0-9. You use them to type data into the PTC. Function keys include the ENTER, FUNC, ON/OFF, and SHIFT keys. They are used to perform a special procedure or function. ENTER key - How you use this key depends on your application. Usually you press this key to tell the application that you have finished typing data, have finished an operation, or want the PTC to begin an operation, such as sending data to the host computer. FUNC key - This key activates the letters, symbols, or functions above the PTC’s keys (for example, pressing the FUNC key followed by the 7 key generates the letter Q). The FUNC key can also be used with the Backlight button to adjust the contrast of the PTC’s display. See page 27 for details. ON/OFF key - Pressing this key turns the PTC on or off. SHIFT key - This key activates the symbols on the left side of the number keys (for example, pressing the SHIFT key followed by the 7 key generates the & symbol). 3. This 15-pin connector connects the PTC via cable to a host computer or to standard serial devices such as printers and modems. It can also be used with an AC adapter to recharge the PTC’s lithium-ion or nickel-cadmium battery pack. Refer to Appendix C for cable part numbers. 4. Pressing this button activates the PTC’s internal laser scanner or image reader, allowing you to scan 1D bar codes or to decode 1D and 2D bar codes and capture handwritten signatures, respectively.
22
Page 25
Figure 2. The PTC-960LE (front view)
1. Good Scan LED
2. Scan LED 3. Display screen
4. Charging LED
5. Optical interface (below micro DB-15 connector) 1. This green light-emitting diode (LED) glows when the PTC’s internal laser scanner or image reader has successfully read a 1D bar code or decoded a 1D or 2D bar code or captured a handwritten signature, respectively. 2. This red LED glows when the PTC’s Scan button has been pressed to activate the internal laser scanner or image reader. 3. The liquid crystal display (LCD) screen shows the information you type or scan into the PTC as well as messages from the PTC or host computer. The screen can show 4 or 8 lines of information with 16 or 21 characters each. Your screen is also able to display graphics. An additional line at the bottom of the display is reserved for status indicator icons. These icons are as follows: Shift Mode Enabled
Caps Lock Enabled
Func1 Is Activated
Func2 Is Activated
Low Battery
4. This red LED glows when the PTC’s lithium-ion or nickel-cadmium battery pack is being recharged. 5. This interface allows the PTC to communicate with a host computer through an optional optical communication cradle. Instead of sending data in the form of electronic signals through the micro DB-15 connector, the PTC sends the data in the form of pulses of light to a similar interface on the cradle. Then the cradle converts the pulses of light into electronic signals and transmits them to the host computer or to an external peripheral. The cradle can also send data to the PTC via the optical interface. Refer to the SC-960LE/WM-960LE User’s Guide or the VC-960LE User’s Guide for instructions on using the cradle.
23
Page 26
Figure 3. The PTC-960LE (back view)
5. Scanner lens
1. Handstrap (not shown)
4. Battery pack latch
2. Battery pack
3. Charge contacts
1. An elastic handstrap on the back of the unit allows you to hold the PTC securely during operation. The bottom of the handstrap must be detached from the unit when the PTC’s battery pack needs to be replaced. See page 33 for instructions on removing the handstrap. 2. The PTC-960LE is powered by a rechargeable lithium-ion or nickel-cadmium battery pack. 3. When the PTC is inserted into an optional communication cradle, these contacts connect with similar contacts on the cradle, allowing the PTC’s battery pack to be fast charged. 4. Sliding this latch toward the top of the PTC allows you to remove the battery pack. Sliding the latch toward the bottom of the PTC secures the battery pack to the back of the unit. 5. The laser light emitted from the PTC’s internal laser scanner or the illuminated crosshairs emitted from the PTC’s internal image reader exits the unit through this lens. $ Do not stare into the laser beam or point the scanner at anyone’s eyes while the scanner is active; permanent eye damage could result.
24
Page 27
Features
7
Autodiscrimination between bar codes See Appendix B for a list of the bar codes your PTC can be programmed to read.
If your PTC-960LE contains a laser scanner, it can be programmed to read and automatically discriminate between up to six different types of 1D bar codes. If your PTC contains an image reader, it can be programmed to decode and automatically discriminate between up to six 1D bar-code types and four 2D bar-code types.
Automatic off To conserve battery power, the PTC automatically turns itself off after approximately 1 minute of inactivity. The exact length of time depends on your application program.
Automatic return at on When you turn off the PTC-960LE (or when the PTC turns itself off), it remembers where it was in the application. Then, when you turn the PTC back on, it returns to that same point in the application. You do not need to review what you have done or perform any other start-up function to find your place.
Backlight Once the backlight is turned on, a timer running within the PTC may turn it off again.
The screen’s backlight lights up the screen and makes information on the display readable in dark or dim conditions. Pressing the Backlight button turns the backlight on or off.
25
Page 28
Backup battery ! Do not store the PTC-960LE for over two months without charging or replacing the battery pack. Both the main battery and the backup battery will be drained, and any data or programs in the PTC’s memory will be lost.
The PTC-960LE’s built-in backup battery provides enough power to protect data stored in the PTC’s memory when the battery pack is being replaced or if it runs out of power. The backup battery system provides approximately 20 minutes of protection when the battery pack is removed.
Beeper The PTC’s beeper is used by the PTC and your application to warn you of problems or to prompt you to take an action. For example, if your application program has temporarily disabled a key, the PTC will beep if you press that key. Depending on your organization’s application software, you may be able to control the beeper’s volume. See the manual or instructions provided by your organization.
Clock The PTC-960LE has a built-in clock that keeps track of the date (month, day, year, and day of the week) and the time (hours, minutes, seconds, and tenths of seconds). The clock operates continuously. How the clock is used depends on your application program. For example, the PTC can use the clock to show the date and time on its screen or to time-stamp a file.
Communication The PTC-960LE is capable of communicating with a host computer through its internal radio, through an optional optical communication cradle, or by being connected directly via a cable. See the manual or instructions provided by your organization for the proper communication procedure for your application.
26
Page 29
Display contrast During its 16-step cycle, the contrast loops from darkest to lightest.
You can increase or decrease the display contrast in steps by pressing the FUNC key and then the Backlight button.
Memory The PTC-960LE has two types of memory: read-only memory (ROM) and random access memory (RAM). The PTC’s ROM is contained on an electronic chip called a flash EPROM, which can be reprogrammed while inside the PTC. It is used to store the PTC’s operating system and application program. RAM is used to store data entered into the PTC and application configuration settings. Data stored in RAM can be easily read, written, and changed. It is also volatile. All data in RAM will be lost if the PTC’s battery pack and backup battery run out of power. The amount of memory in your PTC determines how much data you can enter before you have to send it to a host computer or print it. Various amounts of memory are available from Telxon, and the amount actually installed in your PTC has been determined by your organization’s needs.
27
Page 30
Using the PTC’s laser scanner or image reader
8
Using the PTC’s internal laser scanner (optional) If your PTC-960LE contains a laser scanner, the unit can be programmed to automatically recognize, read, and discriminate between up to six 1D bar-code types. See Appendix B for a list of these bar-code types and the information provided by your organization for details on how your PTC has been programmed. $ Do not stare into the PTC’s laser beam or point the scanner at anyone’s eyes. Permanent eye damage could result.
Follow this procedure to scan bar-code labels with the PTC-960LE’s built-in laser scanner.
See the information provided by your organization for the recommended scanning distance.
The maximum distance from the scanner lens to the label depends on the size of the label being scanned and the type of laser that was selected by your organization.
Your application program may not support scanned data for all fields. Consult the documentation for your application to determine when the scanner and Scan button are enabled.
1. Point the PTC-960LE at the label to be scanned.
2. Press the PTC’s Scan button to start scanning. The red Scan LED glows while the scanner is active. 3. Watch the line of light made by the scanner as it scans the bar code. 4. Hold the PTC at an angle to the bar code so that the light emitted from the scanner is not perpendicular to the label’s surface.
If the scan is successful, the green Good Scan LED glows, and the PTC beeps.
Make sure the scanning line is perpendicular to the bars in the bar-code label and passes over all of the bars. See Figure 4.
28