Page 47
Chapter
12
Troubleshooting If you experience any of the problems in this section, follow the instructions provided.
PTC does not turn on •
Recharge or replace the lithium-ion or nickelcadmium battery pack.
•
Contact your Symbol service representative.
Laser scanner does not read a label
Refer to Appendix B for recommended scanning distances.
Refer to the section titled "Cleaning the PTC," on page 35, for instructions.
PTC-960SL-III User’s Guide
•
Make sure the bar-code label that you are attempting to scan is one of the bar-code types that your PTC is programmed to recognize.
•
Move the laser scanner closer to or farther away from the bar-code label. The scanner may be too close or too far from the bar-code label.
•
Change the angle of the laser scanner to the barcode label. The scanner may be too far above or below the bar-code label, or too far to the side to scan properly.
•
Clean the scanner lens.
•
The PTC’s application program may not support scanned data at this particular field. Consult the documentation for the PTC’s application program to determine when the scanner and trigger are enabled.
37
Page 48
Chapter 3 Configuring TN-3270/5250
•
Point the scanner at a blank surface and press the scanner trigger. Look for the scanning line or aiming dot that appears on the blank surface when the scanner is operating. If no scanning line or aiming dot appears, follow your organization’s procedure to have the scanner serviced. Note:
If your PC is equipped with an M88 imager, you will see a red cross rather than a line or a dot.
Radio fails to establish contact •
Change your location by a few feet and transmit again.
•
Make sure the antenna is attached.
•
Recharge or replace the PTC’s lithium-ion or nickel-cadmium battery pack.
•
Make sure the receiving equipment is turned on and is properly connected to the host computer.
•
If the PTC still does not establish contact, follow your organization’s procedure to have the PTC serviced.
Other problems If you experience any other problems with your PTC-960SL-III that you cannot solve, notify your Symbol service representative or contact the Symbol Support Center at 1-800-653-5350.
38
PTC-960SL-III User’s Guide
Page 49
Appendix A Specifications Communication and I/O Serial:
RS-232 via micro DB-15 connector; 300 to 38,400 baud.
Optical:
Via optical contacts and SC-960SL-III.
Internal radio:
Optional 2.4-GHz directsequence spread spectrum radio or 2.4-GHz frequency-hopping spread spectrum radio.
Spread spectrum radio data rates 2.4 GHz DS: 2.4 GHz FH:
11 Mbps. 2 Mbps.
Display
PTC-960SL-III User’s Guide
Type:
FSTN monochrome liquid crystal display.
Text mode:
8 or 16 lines with 16 or 21 characters; double-height character option available.
Microradio:
Optional 433-Mhz microradio.
Graphics mode:
128 x 128 pixel resolution.
Pixel size:
0.015 x 0.014 in./0.38 x 0.36 mm.
Active area:
2.1 x 1.9 in./53.3 x 48.3 mm.
Backlight:
Electro-luminescent (EL) panel. 39
Page 50
Chapter 3 Configuring TN-3270/5250
Electrical Battery pack:
500 mAh nickel-cadmium or 1,300 mAh lithium-ion.
Backup battery:
Supercap.
Power module Input: Output:
110 VAC @ 50/60 Hz. 12 VDC @ 200 mA.
Environmental Operating temperature Standard units: Low temp. units: M88 imagers:
–4° to 122° F (–20° to 50° C). –22° to 70° F (–30° to 21° C). 32° F (0° C) to 122° F (50° C).
Relative humidity Standard units: Low temp. units:
95% non-condensing. 70% non-condensing.
Storage temperature:
–40° to 167° F (–40° to 75° C).
Shock:
4 ft/1.2 m drop to concrete.
Vibration:
Loose cargo 1" peak-to-peak orbital movement @ 400 RPM.
Operating altitude:
Up to 15,000 ft/4,572 m.
ESD protection:
15 kV.
Keyboard
40
Types:
45-key alphanumeric (standard), 28-key numeric (optional), 11-key consumer scan (optional).
Keypad options:
DOS, 3278/5251, or ANSI/VT220.
PTC-960SL-III User’s Guide
Page 51
Specifications
Laser scanner Refer to Appendix B for a list of supported bar-code types and scanning range specifications.
Options:
SE-1200, or SE-1200LR, or SE-1200HP.
Safety classification:
Class II.
Imager:
M88 image reader.
Memory Flash EPROM Application: 512 KB. Operating System: 256 KB. RAM:
1 to 4 MB.
Microprocessor Type:
V20H/80C88 @ 10 MHz (for terminal processing) and Z182 (for RF communications).
Physical Length:
8.5 in./21.6 cm.
Width:
3.5 in./8.9 cm.
Depth:
7 in./17.8 cm.
Weight:
22 oz/0.62 kg (w/ nickel-cadmium battery pack); 26 oz/0.73 kg (w/ radio and nickel-cadmium battery pack).
Software
PTC-960SL-III User’s Guide
Operating system:
MS-DOS 5.0 or TCAL.
RF term. emulation:
3278, 5251, or ANSI/VT220.
41
Page 52
Chapter 3 Configuring TN-3270/5250
42
PTC-960SL-III User’s Guide