Page 347
PERIPHERAL DEVICES & ACCESSORIES
7
7.1 External Bar Code Readers. . . . . . . . . . . . . . . . . . . . . . . . . . 323 7.1.1 PowerScan™ Standard, LR and XLR Bar Code Scanners . . . . . . 323 7.1.2 Entering Data With The Bar Code Reader. . . . . . . . . . . . . . . 323 7.2 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 7.2.1 Lithium-Ion Battery Safety Precautions . . . . . . . . . . . . . . . . 323 7.3 Important Charger Safety Instructions . . . . . . . . . . . . . . . . . . . . 325 7.4 Chargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 7.5 Gang Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 7.5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 7.5.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 7.5.3 Charge Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 7.5.4 Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 7.5.5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 7.5.5.1 Excessive Charge Duration . . . . . . . . . . . . . . . . . . . 328 7.5.5.2 Indicator Flashing Red . . . . . . . . . . . . . . . . . . . . . 329 7.5.5.3 Power LED Does Not Light Up. . . . . . . . . . . . . . . . . 329 7.5.5.4 Indicator Does Not Light When Battery Installed . . . . . . . 329 7.6 Combo Charger. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 7.6.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330 7.6.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 330 7.6.3 Using the Combo Charger With The 7535/7530 . . . . . . . . . . . 330 7.6.4 Charging The Spare Battery . . . . . . . . . . . . . . . . . . . . . . 330 7.6.5 Charge Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 7.6.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 7.7 Combo Dock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 7.7.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 7.7.2 Using The Combo Dock . . . . . . . . . . . . . . . . . . . . . . . . 332 7.7.3 Network Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
321
Page 348
Chapter 7: Peripheral Devices & Accessories
7.7.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 7.8 Quad Dock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 7.8.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 7.8.2 Indicators And Controls . . . . . . . . . . . . . . . . . . . . . . . . 334 7.8.3 Using The Quad Dock . . . . . . . . . . . . . . . . . . . . . . . . . 334 7.8.4 Network Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 7.8.4.1 Network Addressing . . . . . . . . . . . . . . . . . . . . . . 334 7.8.5 Battery Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 7.8.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335 7.8.6.1 Network Link Unsuccessful . . . . . . . . . . . . . . . . . . 335 7.8.6.2 7535/7530 LED Does Not Light When Docked. . . . . . . . 335 7.9 Portable Docking Module (PDM) . . . . . . . . . . . . . . . . . . . . . . 335 7.10 Bluetooth Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 7.11 The 7535/7530 Picker Cradle . . . . . . . . . . . . . . . . . . . . . . . . 338 7.11.1 Picker Cradle Mounting Recommendations . . . . . . . . . . . . . 339 7.11.1.1 Mounting Template . . . . . . . . . . . . . . . . . . . . . . 339 7.11.2 Wiring Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 7.11.3 Using The Picker Cradle . . . . . . . . . . . . . . . . . . . . . . . 340 7.11.4 Maintaining The Picker Cradle . . . . . . . . . . . . . . . . . . . . 340 7.11.5 Powered Cradle Installation In High Voltage Vehicles . . . . . . . . 340 7.11.6 Powered Cradle Installation . . . . . . . . . . . . . . . . . . . . . . 341 7.11.6.1 Wiring Vehicle Power To The Cradle . . . . . . . . . . . . 342 7.11.7 The Port Replicator . . . . . . . . . . . . . . . . . . . . . . . . . . 343
322 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 349
Chapter 7: Peripheral Devices & Accessories External Bar Code Readers
7.1 External Bar Code Readers 7.1.1 PowerScan™ Standard, LR and XLR Bar Code Scanners Note:
Refer to “PowerScan™ Standard Range Scanner Specs” on page 368 and “PowerScan™ LR and XLR Industrial Scanner Specs” on page 366 for detailed specifications.
The 7535/7530 supports Psion Teklogix’ PowerScan™ industrial bar code scanner with standard, long range and extra long range options. To connect this scanner to the 7535/7530, attach the device to the tether port at the upper-right side of the 7535/7530. Before using the bar code reader, you may need to change some parameters. Review your “Power Scan Programing Guide (PSC)” for details.
7.1.2 Entering Data With The Bar Code Reader Note:
For helpful scanning tips, refer to “Scanning Techniques” on page 55.
When a label is scanned successfully, the 7535/7530 will beep if configured appropriately and the scan LED will flash. Occasionally, the bar code labels are poorly printed or damaged and cannot be read properly. In this case, use the keyboard to enter data from the label.
7.2 Batteries Note:
Battery specifications are detailed beginning on page 371.
7535/7530s operate with Lithium-Ion batteries – the 7535 with a high capacity 1900 mAh battery pack and the 7530 with either a high capacity, 1900 mAh battery pack or an extra capacity, 2400 mAh battery.
7.2.1 Lithium-Ion Battery Safety Precautions Important:
It is critical that this safety information be reviewed and that all warnings be strictly followed.
Warning:
BATTERIES ARE CONSIDERED HAZARDOUS WASTE and must be returned to Psion Teklogix for proper disposal. All used batteries must be forwarded to one of the following offices:
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
323
Page 350
Chapter 7: Peripheral Devices & Accessories Lithium-Ion Battery Safety Precautions Psion Teklogix Inc. Psion Teklogix Corp. 2100 Meadowvale Blvd. 1810 Airport Exchange Blvd. Mississauga, Ontario Suite 500 Canada Erlanger, Kentucky L5N 7J9 USA 41018 Psion Teklogix S.A. La Duranne; 135 Rue Rene Descartes; BP 421000 13591 Aix-En-Provence Cedex 3; France Warning:
TO PREVENT the battery from leaking acid, generating heat or exploding, adhere to precautions listed below. • •
• • • • • • • • • • • • •
The battery incorporates built-in safety devices. To ensure their proper function, do not disassemble or alter any parts of the battery. Do not short-circuit the battery by directly connecting any of the exposed terminals with metal objects such as wire. Do not transport or store the battery together with metal objects such as necklaces, hair pins, etc. Do not dispose of batteries in fire. Do not use or leave the battery near a heat source such as a fire or heater. Do not immerse the battery in water. When charging, use the battery charger specifically designed for the battery. Do not pierce, strike, throw or step on the battery. Do not directly solder the battery. Do not connect the battery to an electrical outlet, vehicle cigarette lighter, etc. Do not put battery into a microwave oven or pressurized container. Do not use the battery in combination with primary batteries (such as dry-cell batteries) or batteries of different capacities or brands. Immediately remove the battery from the device or battery charger and stop use if the battery gives off an odor, generates heat, becomes discoloured or deformed, or in any way appears abnormal during use. Do not continue charging the battery if it does not recharge within the specified charge time. The battery may burst or ignite if the battery leaks. Always ensure that it is away from any exposed flames. If leaking electrolyte sprays into your eyes, rinse them with clean running water, and immediately seek medical attention.
324 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 351
Chapter 7: Peripheral Devices & Accessories Important Charger Safety Instructions •
• •
Do not store the battery in extremely high temperatures (e.g., a vehicle, strong direct sunlight, etc.). This may cause the battery to overheat or ignite, and it may also reduce the performance and service life of the battery. Do not use in areas where static electricity is greater than what the manufacturer guarantees. Keep batteries out of reach of children.
7.3 Important Charger Safety Instructions • • • • • • • • • • •
•
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions for battery chargers. Before using the battery charger, read all instructions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery. The mains power cord shall comply with national safety regulations of the country where the equipment is to be sold. Use of an attachment not recommended or sold by the battery charger manufacturer may result in fire, electric shock, or personal injury. To reduce risk of damage to the electric plug and cord when unplugging the charger, pull the plug rather than the cord. Make sure the cord is positioned so that it is not stepped on, tripped over, or otherwise subjected to damage or stress. Do not operate the charger with a damaged cord or plug. Replace immediately. Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; it should be inspected by qualified service personnel. Do not disassemble the charger; it should be repaired by qualified service personnel. Incorrect reassembly may result in electric shock or fire. To reduce risk of electric shock, unplug the charger from the outlet before attempting any maintenance or cleaning. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in fire or electric shock. If an extension cord must be used, make sure: • The plug pins on the extension cord are the same number, size, and shape as those on the charger. • The extension cord is properly wired and in good electrical condition and that the wire size is larger than 16 AWG. Do not expose the charger to rain or snow.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
325
Page 352
Chapter 7: Peripheral Devices & Accessories Chargers •
•
•
Do not place batteries in the charger if they are cold from extended exposure to a freezer or outside temperatures below 10°C (50°F). Allow them to warm up to temperatures for at least two hours. Battery temperature should be between 5° C and 39° C (41° F to 102° F). Do not use the charger if, after an overnight charge, any of the batteries feel warmer than the charger housing. The charger should be inspected by qualified service personnel. Do not use the charger if any of the batteries or the charger get more than lukewarm. The equipment should be inspected by qualified personnel.
7.4 Chargers Note:
Initially, new batteries that have been fully charged may indicate less than 100% charge. No special conditioning is required. The full capacity of the battery will reach 100% after 5 cycles through the charger.
It can take from 1.5 to 4 hours to charge a battery. The 7535/7530’s intelligent charging system protects the battery from over-charging by terminating the charge process when the battery is at maximum capacity. Important:
To preserve battery integrity, the charger will proceed with a charge only when the battery temperature falls between 5° C and 39° C (41° F to 102° F). If the battery is too hot or cold, the battery status LED flashes yellow and the charge is suspended.
7.5 Gang Charger
The gang charger is designed to charge up to six 7535/7530 Lithium-Ion batteries at one time. Your charger is shipped with the appropriate IEC mains power cord. If the supplied power cord is incorrect for your country, contact Psion Teklogix for assistance (see Appendix A: Support Services And Worldwide Offices). Note:
The gang charger is shipped with a user manual. It is critical that this manual be reviewed for additional information and updates.
326 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 353
Chapter 7: Peripheral Devices & Accessories Installation
7.5.1 Installation
The gang charger can be wall mounted using the wall mount kit – PN 1010039 – or it can be operated on a flat surface. Install the charger in an area that is free from excessive dirt, dust and contaminants. The ambient temperature must be in the range 5° C to 39° C (41° F to 102° F). The charger will not charge batteries outside of this temperature range. For maximum performance, it is recommended that the charger be operated at room temperature – a temperature range between 18° C to 25° C (64° F to 77° F). The charger can consume up to 2A @ 120VAC or 1A @ 240VAC. Check to ensure the mains circuit supplying the charger is adequate for this loading (especially if several chargers are being powered from the same circuit). After unpacking the unit: • •
Visually check the charger for damage. Install the IEC power cord and apply power.
A green indicator in the lower-right lights to indicate power is present. All charge indicators flash momentarily at powerup to indicate that the charger is ready for operation. If you choose to wall mount the charger, follow the instructions packaged with the mounting bracket kit. Be sure to locate the charger in an area where there is no risk of injury to persons walking in the vicinity.
7.5.2 Operator Controls
The gang charger does not have operator controls or a power switch.
7.5.3 Charge Indicators
Each battery charge slot is equipped with a tri-coloured LED to indicate the charge status of the battery. When 7535/7530 batteries are inserted in the charger, the colour and behaviour of the LEDs associated with the charge wells in use indicate the status of the charge.
LED Behaviour Off
Icon
Charge Status No battery detected in the slot.
Solid green
Battery is fully charged.
Flashing green
Battery is charged to 75% capacity.
Solid yellow
Charge in progress.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
327
Page 354
Chapter 7: Peripheral Devices & Accessories Charging Batteries
Flashing yellow
Battery temperature out of charge range between 5° C to 39° C (41° F to 102° F). This icon indicates that the charger is waiting to charge. Charging is attempted every five minutes until the battery is within the appropriate temperature range.
Solid red
Battery rejected (at insertion) or unable to complete charge on battery
Flashing red
Charging circuit problem. Refer to “Troubleshooting” on page 328.
Table 7.1 Gang Charger Indicators
7.5.4 Charging Batteries •
Install the battery with the battery contacts facing the charger. Slide the battery between the guide rails until it lightly latches in place.
The LED directly below the slot in which a battery is inserted lights up immediately. A solid yellow LED indicates that the battery is being charged. If the battery temperature is outside 5° C to 39° C (41° F to 102° F), the LED flashes yellow until the temperature is acceptable. A fully discharged battery will normally take between 1.5 and 4 hours to charge. When the battery charge reaches 75%, the indicator flashes green. At full capacity, it turns solid green. When the battery is fully charged, the charger stops applying power; the battery cannot be overcharged if left in the charger slot. The 75% charge indicator is handy if you need a quick recharge – it often occurs after less than an hour.
7.5.5 Troubleshooting 7.5.5.1
Excessive Charge Duration
The charger is equipped with a recalibration function – a function that fully discharges and then fully recharges the battery. This process is necessary to recalibrate the battery capacity gauge internal to the battery. The charger attempts recalibration when: • • the battery capacity is at less than 30%, and the battery has undergone more than 40 partial charge cycles since the last full discharge.
A complete battery discharge takes between 1.5 and 4 hours to complete. When in discharge mode, the LED indicator flashes yellow. The recalibration function extends the charge time by up to 2 hours.
328 Psion Teklogix 7535/7530 Hand-Held Computer User Manual