Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 48

7535/7530 Hand-Held Computer User Manual: Configuration 5, pages 131 to 140

Pages 131 to 140 of 440, from 7535/7530 Hand-Held Computer User Manual

The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7530 and Teklogix 7535

Page 131

Chapter 5: Configuration Scancode Remapping

5.5.2.6

Scancode Remapping

A scancode is a number that is associated with a physical key on a keyboard. Every key has a unique scancode that is mapped to a virtual key, a function or a macro. Scancode Remapping allows you to change the functionality of any key on the keyboard. A key can be remapped to send a virtual key (e.g. VK_F represents the ‘F’ key; VK_RETURN represents the <ENTER/ON> key, etc.), perform a function (e.g. turn the scanner on, change volume/contrast, etc.) or run a macro. There are three different tables of scancode mappings: the Normal table, the Blue table and the Orange table. The Normal table defines unmodified key presses; the Blue table defines key presses that occur when the <BLUE> modifier is on; the Orange table defines key presses that occur when the <ORANGE> modifier is on. The default mappings of these scancodes can be overwritten for each of these three tables using the Scancode Remapping tab accessed from the Keyboard Properties dialog box.

Figure 5.14 Scancode Remapping The first column in the Scancode Remapping tab displays the scancodes in hexidecimal. If the scancode is remapped to a virtual key, that virtual key is displayed in the next column labelled ‘V-Key’. A virtual key that is ‘Shifted’ or ‘Unshifted’ is displayed in the third column labelled ‘Function’.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

105

Page 132

Chapter 5: Configuration Scancode Remapping If the scancode is remapped to a function or a macro, the first and second columns remain blank while the third column contains the function name or macro key number (e.g., Macro 2).

Adding A Remap To add a new remapping: •

Choose the Add button at the bottom of the dialog box.

The Remap Scancode dialog box is displayed.

Figure 5.15 Remapping A Key •

Type the scan code in hexidecimal in the field labelled Scancode

Note:

The Label field displays the default function of the scancode you are remapping.

Virtual Key, Function And Macro The radio buttons along the side of the dialog box allow you to define to what the scan code will be remapped: Virtual Key, Function or Macro.

106 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 133

Chapter 5: Configuration Scancode Remapping When Virtual Key is selected, you can choose to force <SHIFT> to be on or off when the virtual key is sent. If No Force is selected, the shift state is dependent on whether the shift state is on or off at the time the virtual key is sent. When Function is selected, a list of valid functions appears in the dialog box. When Macro is selected, the macro keys available on your unit are listed in the dialog box. •

Choose Virtual Key, Function or Macro.

•

Choose a function from the Function list in the dialog box, and tap on OK.

Editing A Scancode Remap To edit a scancode: •

In the Scancode Remapping tab, tap the stylus on the remap you want to edit.

•

Tap on the Edit button, and make the appropriate changes.

•

Tap on OK to save your changes.

Removing A Remap To delete a remap: •

In the Scancode Remapping tab, highlight the scancode you want to delete, and tap on the Remove button.

•

Tap on OK.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

107

Page 134

Chapter 5: Configuration Volume And Sound Properties

5.5.3 Volume And Sound Properties Note: •

The conditions under which hand-helds emit sounds are tailored from within the application installed on your unit. In the Control Panel, choose the Volume & Sounds icon.

Figure 5.16 Choosing The Volume Icon

5.5.3.1

Volume Adjustments

Figure 5.17 Volume Settings •

Slide the volume button to the left to lower the beeper volume or to the right to increase the beeper volume.

108 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 135

Chapter 5: Configuration Sound •

5.5.3.2

Under the heading Enable sounds for, enable the conditions under which you want the 7535/7530 to emit a beep.

Sound

Figure 5.18 Sound Settings The 7530 hand-held computer is equipped with a sound port. This dialog box allows you to determine the sound file that will be emitted from this port.

5.5.4 Power Management Properties

This icon displays a Power Properties dialog box that indicates the unit’s battery capacity and allows you to manage battery use. • In the Control Panel, choose the Power icon.

Figure 5.19 Choosing The Power Icon Psion Teklogix 7535/7530 Hand-Held Computer User Manual

109

Page 136

Chapter 5: Configuration Battery Capacity

5.5.4.1 •

Battery Capacity In the Power Properties dialog box, open the Battery tab to view battery details.

Figure 5.20 Power Battery Properties

5.5.4.2 •

Power Saving Schemes In the Power Properties dialog box, open the Schemes tab.

Figure 5.21 Power Scheme Properties – AC Power And Battery Power

Power Scheme This dropdown menu allows you to specify whether the unit is using AC Power or Battery Power. 110 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 137

Chapter 5: Configuration Suspend Threshold

Switch State To Suspend Important:

Psion Teklogix recommends setting the Suspend value to 10 minutes. Setting ‘Switch State To Suspend’ to ‘Never’ will adversely affect the battery run time. To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Display Backlight” on page 95). When the 7535/7530 is idle – not receiving any user input (a key touch, a scan, and so on) or system activity (serial data, an activity initiated by an application, and so on), the hand-held uses the value assigned in the Switch State To Suspend field to determine when the unit will go to sleep (appear to be off). When the time in the Suspend field elapses without any activity, the unit enters suspend state. In suspend state, the 7535/7530 CPU enters a sleep state, and the radio is shut off. The state of the device (RAM contents) is preserved. Pressing <ENTER> wakes the system from suspend state. When the 7535/7530 is in suspend state, the network connection will not be broken immediately. If the connection is dropped, you must re-establish the network connection.

5.5.4.3

Suspend Threshold

Figure 5.22 Advanced Tab The Suspend Threshold adjustment tells the system when to shut down when the battery drains. If you choose Maximum Operating Time, the unit will run until the battery is completely empty; the RAM is only backed up for a short period of time. If you choose Maximum Backup Time, the hand-held shuts off with more energy left in the battery so RAM can be backed up for a longer period of time.

Psion Teklogix 7535/7530 Hand-Held Computer User Manual

111

Page 138

Chapter 5: Configuration Charger

5.5.4.4

Charger

Figure 5.23 Charger Tab Tapping in the checkbox next to Allow Battery Calibration allows the battery to be recalibrated only when necessary if the unit is inserted in a Combo Docking station.

5.5.4.5

Card Slots

This tab enables or disables power to individual CF, PC Card and SDIO slots in the unit.

Figure 5.24 Card Slot Activation Remember to tap on the Apply button and then tap on OK to save your changes.

112 Psion Teklogix 7535/7530 Hand-Held Computer User Manual

Page 139

Chapter 5: Configuration Stylus Properties

5.5.5 Stylus Properties Note: •

Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor. In the Control Panel, choose the Stylus icon.

Figure 5.25 Stylus Icon

5.5.5.1 •

Setting Double-Tap Sensitivity In the Double-Tap tab, follow the directions to tailor the sensitivity of the stylus when you tap on the touchscreen.

Figure 5.26 Setting Stylus Sensitivity Psion Teklogix 7535/7530 Hand-Held Computer User Manual

113

Page 140

Chapter 5: Configuration Touchscreen Calibration

5.5.5.2

Touchscreen Calibration

Touchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below. •

Choose the Calibration tab, and then tap on the Recalibrate button.

Figure 5.27 Calibrating The Touchscreen •

5.5.5.3

Follow the directions in the Calibration tab to recalibrate the screen.

Touchscreen Options

This tab allows you to disable the touchscreen. •

Choose the Options tab, and select the checkbox next to Disable the touch panel.

114 Psion Teklogix 7535/7530 Hand-Held Computer User Manual