Page 83
Chapter 3: Getting To Know Your 7535/7530 Operating Internal PDF Laser Scanners
3.8.5 Operating Internal PDF Laser Scanners This scanner decodes PDF417 two-dimensional bar codes. •
Turn the hand-held on. Wait until the unit has booted up completely.
•
Aim at the bar code and press the scan key or the trigger. The beam expands into a rectangle covering the bar code to properly scan it. The scan beam and a warning indicator are visible until a successful decode is achieved or three seconds have elapsed.
3.8.6 Operating Internal Two Dimensional (2D) Imager Scanners An imager scanner takes a snap shot of a single bar code or multiple bar codes (at one time). It can find a bar code regardless of its orientation – that is, even a bar code printed at a 45 degree angle to the hand-held will be decoded successfully. Note:
When scanning multiple bar codes, ensure that all of the desired bar codes are within the field of view of the scanner. It is possible that even when all bar codes are within the field of view, not all of them will be decoded. Only successfully decoded bar codes are passed to the application program. The application program then issues a warning, asking that you scan the missing bar codes. When scanning a single bar code, ensure that only the desired bar code is within the field of view of the scanner.
Because imager scanners generally have a shorter depth of field than laser scanners, some practise may be required to find the optimal distance from the types of bar codes being scanned. Although the imager includes illumination LEDs, ambient light will help the imager decode the bar codes, especially if the bar code is far from the hand-held. Important:
•
Keep in mind that the imager scanner is a camera, and the LED illumination is a flash. Glare can be an issue on reflective media such as plastic coated bar codes, just as glare is an issue for photographers. When pointing at a shiny surface, either shift the bar code to the side or top, or angle the bar code so that the glare reflects away from the imager scanner.
Turn the hand-held computer on. Wait until the unit has booted up completely.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
57
Page 84
Chapter 3: Getting To Know Your 7535/7530 Operating RFID/Scanner Modules •
Aim at the bar code and press the scan key or the trigger.
•
When the scan button or trigger is pressed, a red, oval shaped light (the framing marker) is displayed. Centre the framing marker in the field – either in the centre of the bar code you want to scan or in the centre of the area in which multiple bar codes are to be scanned.
Illumination LEDs will flash and a picture of the bar code(s) is taken.
3.8.7 Operating RFID/Scanner Modules The RFID module is a short-range device. Configuration is not required for the RFID reader. Important:
For successful reads, the distance from the hand-held to the RFID tag varies depending on the type of tag.
Reading An RFID Tag • •
Turn the hand-held on. Wait until the unit has booted up completely. Position the scanner window of the 7535/7530 no more than 1 centimetre from the tag. Depending on the type of tag you are reading, you may actually need the 7535/7530 scanner window to touch the RFID tag.
To test how the unit reads and writes RFID tags, a demonstration application has been provided. The demo application - RfidReader - is located in the \Windows folder. This demo application performs the following tasks: • • • • •
58
Loads the internal RFID device driver and displays driver/device information. Reads the in-range tag data when the scan trigger is pressed. Converts the tag data to text format and outputs the text to the keyboard buffer. Provides a UI (User Interface) to notify the operator that the RFID device is currently active (since there is no physical indicator from the reader). Provides a UI to allow the operator to modify various text conversion settings.
Note:
The UI (User Interface) for this application is a single system tray icon. The icon changes when the RFID device is active and also indicates a successful or unsuccessful scan. In addition, it displays a “scanning” bar code indicator during the read process.
•
Caches a short list of previously read tags to make it easier for the operator to repeat the ‘output to keyboard buffer’ process.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 85
Chapter 3: Getting To Know Your 7535/7530 Connecting & Disconnecting Tethered Peripherals
Scanning A Bar Code • •
Note:
Turn the hand-held on. Wait until the unit has booted up completely. Aim at the bar code and press the scan key or the trigger. The beam expands, covering the bar code to properly scan it. The scan beam and a warning indicator are visible until a successful decode is achieved or three seconds have elapsed. The SE923 scanner is not equipped with a targeting dot.
3.9 Connecting & Disconnecting Tethered Peripherals Tethered peripherals such as scanners and printers connect to the hand-held computer with a quick release, circular connector. When a peripheral is connected to the hand-held, the unit detects the peripheral and loads the necessary drivers for it. An icon in the taskbar at the bottom of the screen provides a visual representation of the peripheral and indicates that it is ready for operation. To attach the peripheral to the round, tether port on the side of the unit: •
Insert the barrel of the plug into the tether port and rotate slowly until it clicks into place. The red dot on the port and on the connector should be aligned.
Figure 3.10 Attaching The Cable To The Tether Port
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
59
Page 86
Chapter 3: Getting To Know Your 7535/7530 Monitoring The Battery And Maximizing Run Time To remove the peripheral: •
Grasp the shell of the plug, and pull it back gently to unlock and release the connector.
Figure 3.11 Disconnecting The Tether Cable Important:
Never attempt to disconnect a peripheral by pulling the connector by the wire. The connector is locked into place and can only be unlocked and removed by pulling back the plug shell.
3.10 Monitoring The Battery And Maximizing Run Time Under normal operating conditions, fully charged batteries last for 10 hours. As Lithium-Ion batteries age, their capacity decreases gradually, and they are generally considered depleted after approximately 2 years of use (less than 60% of original capacity remaining). Keep in mind however that heavy usage or operating the 7535/7530 at temperature extremes will shorten the battery life. Lithium-Ion batteries do not require conditioning cycles and the 7535/7530 battery system (including chargers) requires no user interaction to maintain peak performance. To maximize the run time of your batteries, consider the following:
60
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 87
Chapter 3: Getting To Know Your 7535/7530 Monitoring The Battery And Maximizing Run Time •
The display backlight is the largest drain on the battery. Try to keep its brightness as low as possible.
•
The hand-held is ‘event’ driven – that is, when the unit is not in use, it reverts to sleep mode (even when it appears to be running), saving battery power. Events include a key press, touchscreen taps and scan triggers. Power consumption is reduced if you avoid unnecessary events, and allow the unit to sleep as much as possible.
•
The hand-held battery is a ‘smart battery’ with built-in intelligence. The taskbar battery icon is a linear gauge used to estimate the remaining run time of the battery. It is important to note that the battery capacity icon displays quarter percentages of nominal capacity (the capacity of a new battery). An aged battery, even when fully charged, shows somewhat less capacity than nominal. Double-tapping on the battery icon displays a dialog box that provides detailed information about the battery status and performance. If the remaining capacity indication seems inaccurate, the battery may need recalibration. Recalibration requires that the battery be fully charged, discharged and then charged again before use. If the battery is fully discharged and charged on a regular basis, recalibration should not be necessary.
•
When the hand-held is switched off, it goes into a low-power, suspend state but continues to draw a small amount of power from the battery. This should not be an issue unless the unit is left in suspend state for more than a week – in this case, the battery should be removed.
•
Batteries left unused for durations of more than one or two months should be fully charged, discharged and then charged again before use. This recalibrates the gas gauge and allows the internal electronics to determine the actual capacity of the battery.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
61
Page 88
Chapter 3: Getting To Know Your 7535/7530 Storing Batteries
3.10.1 Storing Batteries Long term battery storage is not recommended. If storage is necessary: •
Always try to use a ‘first-in first-out’ approach to minimize storage time.
•
Lithium-Ion batteries age much faster at elevated temperatures. Store batteries at temperatures between 0° C and 20°C.
•
Always charge batteries to 40 to 60% before storing them. Batteries can be damaged by an over-discharge phenomenon that occurs when an empty battery is stored for a long period of time such that the cell voltage drops below a lower limit.
•
To minimize storage degradation, recharge stored batteries to 40 to 60% every 4 or 6 months to prevent over-discharge damage.
•
A ‘never used’ Li-Ion battery that has been stored for 3 years may have limited or no useful life remaining once put into service. Think of batteries as perishable goods.
3.11 Monitoring The Network Connection If your hand-held is equipped with a wireless LAN radio, it will typically associate with the nearest access point. The radio signal quality meter in the taskbar indicates the relative strength of the communication link. To access the radio signal icon: •
Tap on the radio icon in the taskbar to display the wireless statistics dialog box.
To access the radio signal icon using the keyboard: • • • • Note:
62
Press <BLUE> <0> to display the Start Menu. Highlight Shortcuts and then choose System Tray from the sub-menu. Use the <LEFT> and <RIGHT> arrow keys to highlight the radio signal icon in the taskbar. Press <ENTER> to display the Wireless Statistics dialog box. Moving in and out of the radio coverage area can have varying effects on a network session. At times, you may need to renew your connection by logging in again.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 89
Chapter 3: Getting To Know Your 7535/7530 Uploading Data In A Docking Station
3.12 Uploading Data In A Docking Station The Combo Docking and Quad Docking peripherals allow your hand-held to link to an Ethernet network. They are typically used to upload transaction data to a server computer when a radio link is not available. When a 7535/7530 is properly inserted in a docking station, a dock icon is displayed in the taskbar at the bottom of the unit screen. The hand-held also detects the presence of the Ethernet network. Review the documentation provided with the user application installed in your 7535 or 7530 before preforming data uploads.
3.13 General Maintenance 3.13.1 Caring For The Touchscreen The touchscreen is covered with a thin, flexible polyester plastic sheet with a conductive coating on the inside. The polyester can be permanently damaged by harsh chemicals and is susceptible to abrasions and scratches. Using sharp objects on the touchscreen can scratch or cut the plastic, or crack the internal conductive coating. The chemicals listed below must not come into contact with the touchscreen: • mustard, ketchup
• sodium hydroxide,
• concentrated caustic solutions,
• benzyl alcohol, and
• concentrated acids.
If the touchscreen is used in harsh environments, consider applying a disposable screen protector (PN HU6110). These covers reduce the clarity of the display slightly but will dramatically extend the useful life of the touchscreen. When they become scratched and abraded, they are easily removed and replaced.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
63
Page 90
Chapter 3: Getting To Know Your 7535/7530 Cleaning The 7535/7530
3.13.2 Cleaning The 7535/7530 Important:
64
Do not immerse the unit in water. Dampen a soft cloth with mild detergent to wipe the unit clean.
•
Use only mild detergent or soapy water to clean the hand-held unit.
•
Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The 7535/7530 has a plastic case that is susceptible to harsh chemicals. The plastic is partially soluble in oils, mineral spirits and gasoline. The plastic slowly decomposes in strong alkaline solutions.
•
To clean ink marks from the keypad and touchscreen, use isopropyl alcohol.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual