For the Synel SY-785 and Synel SY-780A

Page 46

-

Maintenance This section gives instructions for maintaining good working order for the terminal. The issues described are: • Physical Maintenance • Calibrating the Real Time Clock (RTC) • How to cause the memory to crash • Formatting the memory if a crash occurs • Fingerprint sensor cleaning and care

1

Physical Maintenance

1.1

General

Once every six months: • Check and tighten the screws in the terminal such as the screws holding the power cable to the CPU card. • Verify that all components connected to the sockets are well adjusted.

44

Page 47

-

1.2

Badge Readers

Once a month: • Magnetic badge readers: Once a month - use a special cleaning badge made of plastic with a polishing paper (made of Al2O3, with a grain size of approximately 16 microns) attached to the part of the badge where it contacts the magnetic head. Swipe the badge once or twice. Excessive polishing will result in wearing out of the magnetic reader head. • Clean the reader with a cleaning solution (such as pure alcohol). • Barcode badge readers: Once a month - use an air gun to remove dirt/dust or a special optical cleaner (e.i.: one used for eye glasses). • Use a blower to clean dust off of the head of the reader. Alcohol based cleaning solutions must never be used to clean barcode readers

45

Page 48

-

1.3

Fingerprint sensor cleaning and care

A sensor is designed to provide years of trouble- free service. Although maintenance and handling requirements are few in number, observance of a few basic maintenance procedures help ensure a high level of performance over time. Several types of sensors exist, and each type of sensor requires a different cleaning method. Make sure to use the proper cleaning method for the sensor type you use.

1.3.1

Cleaning for Fingerprint Sensors

Oily deposits from your finger accumulate on the surface of the fingerprint sensor after repeated use. These can inhibit the functionality of the sensor. Scheduled cleaning: It is recommended to clean the sensor at least once a week, and also whenever an oily residue is visible on its surface.

46

Page 49

-

For Capacitive Sensors Use Isopropyl alcohol (rubbing alcohol) and a clean cotton cloth or tissue paper to remove oily deposits. Do not use a soiled cloth or tissue paper. A clean cotton cloth or tissue paper will absorb the deposits, but a soiled cloth will smear the deposits over the sensor’s surface. Alcohol is the preferred cleaning material because it dissolves oily residue and evaporates quickly. The use of nylon brushes or scouring pads, abrasive cleaning fluids or powders, or steel wool is not recommended. For Optic Sensors Use a clean cotton cloth or tissue paper dampened by water or window cleaning solution to remove oily deposits.

47

Page 50

-

1.3.2

Caring for the Fingerprint Sensor. • Do not place the fingerprint sensor close to a heat source, such as a radiator or hot plate. • Do not subject the fingerprint sensor to heavy shocks/vibrations. • Do not allow the sensor to come in contact with metallic objects.

Conditions. The sensor can be stored in temperatures ranging from –650C to +1500C, and can operate in temperatures ranging from 00C to + 600C. Sensors should not be exposed to rain or excessive humidity. A sensor can operate within a range of 5% to 95% humidity (non-condensed). Other than for cleaning, as instructed above in Cleaning for Fingerprint Sensors, do not bring the sensor in contact with and liquids. Authentec Sensors Authentec sensors can be damaged by a discharge of static electricity from a human body. However, the fingerprint sensor is typically encircled by conductive plastic, which is connected, to a ground plane. You should always touch the conductive plastic before touching the sensor in order to safely discharge any static electricity that may be present on your skin or clothing. Electric system • Check the voltage of the UPS battery. If it has less than 7 volts, the batteries need to be changed.

48

Page 51

-

• Visually check the battery for leakage. Clean all of the electrical contacts inside the terminal with a contact cleaner. Checking Backup battery: Making sure that the backup battery is in good condition, according to the following steps: 1.

Collect and clear all the data stored in the terminal.

2.

Open the terminal.

3.

Remove jumper JP7.

4.

Check the voltage of the memory back-up battery and make sure it is between 2.8V and 3.1V.

5.

Replace jumper JP7.

49

Page 52

-

2

Calibrating the Real Time Clock (RTC) This operation must be performed by qualified and authorized personnel only! When working with an open unit, make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source. Failure to heed this warning may result in harmful contact with electrical current.

If your terminal gains or loses time, you will need to calibrate it using a Time Counter unit, which has at least 5 places to the right of the decimal point (100,000ths of a millisecond). 1. 2.

Unplug the terminal and make sure that it is OFF. The backup battery automatically supplies power for approximately 15 seconds. Unscrew and remove the front panel.

3.

Remove the JP12 jumper. This disables the Watchdog utility.

4.

Plug the terminal into a power source and enter the technician mode.

5.

Make sure that the Time Counter is unplugged.

6.

Connect the ground of the Time Counter unit to the ground pin at TP2 of the terminal’s CPU board.

7.

Reposition JP13 to 2-3 (calibration).

8.

Connect the input of the Time Counter unit to the pin in JP13 marked jumper 2.

9.

Plug the Time Counter unit into a power source.

10. Set the Time Counter unit to test the period. 11. Press once on Enter; the message "Adjust RTC N/Y" appears. 50

Page 53

-

12. Press once on Enter, for N (no). Use line up/down to scroll when selecting the Y (yes) option. 13. Calibrate the RTC of the terminal to 3.90625 milliseconds + 0.00003 by turning the screw on the variable capacitor at C18. 14. Disconnect Jumper 2 pin at JP13. 15. Replace the JP13 jumper to 1-2 position. 16. Disconnect the connector from TP2 of the terminal’s CPU board. 17. Return the JP12 jumper to re-enable the Watchdog utility. 18. Unplug the terminal. 19. Replace the front panel. 20. Unplug the Time Counter.

51

Page 54

-

3

How to cause the memory to crash This operation must be performed by qualified and authorized personnel only! When working with an open unit, make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source. Failure to heed this warning may result in harmful contact with electrical current.

3.1 1.

Location of jumpers

2.

Unplug the terminal and make sure that it is off. The back-up battery automatically supplies power for approx. 15 seconds. Unscrew and remove the front panel.

3.

Remove the JP4 jumper from the 1-2 position to 2-3 position.

4.

Reposition JP4 to (1-2).

5.

Plug the terminal back into a power source and make sure that MEM CRASH reappears in the terminal display.

52