Page 73
-
19 JP107
SY-795/ Modem
20 JP106
Rechargable battery VIno / VIn Buzzer
21 JP108 22 J100 23 J101 24 J102 25 J103
(1-2) managing the Default OPEN SY-795 graphic LCD board. (2-3) CTSB for modem for future use Default OPEN for future use (2-3) ON - enable buzzer (ON) OFF - disable buzzer for future use (2-3) for future use (OFF) for future use (OFF)
71
Page 74
-
Appendix D Biometric concepts Biometric Definitions Enrollment is the operation of scanning a fingerprint, determining the quality of the fingerprint scan, and storing a good template together with associated data in the FPU memory. The following enrollment methods are available. One time – Enrolls a scanned fingerprint to a fingerprint template. Supported by all FPU units. Two times – Scans the fingerprint twice. The two images are compared to each other and verified. If the fingerprint images do not match the user is rejected. If they match the better quality fingerprint is enrolled in the template. Supported by FPU- S units only. Two templates – Scans the user finger twice and saves the each fingerprint scan as a template. The user has two templates stored. Then, each time the user is verified, the module can decide whether to replace the existing template with a new one. This update reflects the dynamic changes in the skin of the user's finger. Supported by FPU- S units only.
Scan Save template Modification
One time
Two times
Two templates
-
-
+
1 1
2 1
2 2
72
Page 75
-
Scanning an Image When the FPU properly reads a fingerprint, it looks for image quality and fingerprint content. When a raw image is collected from the sensor during enrollment, for verification or identification, the FPU searches for the fingerprint core. Content scores are based on the amount of unambiguous data in the region of the core. The higher the content, the greater the degree of useful information. See Using Content and Quality for Enrollments for a thorough description of content. Quality scores are based on how well the ridge pattern is defined within the image. For best image quality, be sure that the sensor window is clean of residue, or other material that can block the FPU from the best fingerprint view. Once the image is scanned, the FPU creates and stores the resulting fingerprint template. Verification is the operation of entering a PIN #, requesting the user to place their finger on the FPU, scanning the finger, comparing the current scan against stored fingerprint templates for that user, and then notification of a successful validation or a failure. Identification is the operation of requesting the user to place their finger on the FPU, scanning the finger, comparing the current scan against all stored fingerprint templates (regardless of user). If the user is in the database, identifying the user. Identification is only available on a searching FPU units. Fingerprint Template is the data stored on the FPU that mathematically represents the pattern of an enrolled fingerprint. This data is not the raw image of the fingerprint, but the result of processing the raw image through a unique algorithmic process, preparing the data for later comparisons, and compressing the data for maximum storage. An image of the uncompressed template data does
73
Page 76
- resemble the raw image, but whereas a raw image is 90K bytes, the compressed template is only around 400 bytes. Fingerprint Core is the term used to describe distinguishing print characteristics usually found in the area of the print where the topography shows the tightest curvature. Although the entire fingerprint has significant data, the “core” is the most data- intensive area and therefore very important. Proper Finger Placement The basics for successful operation of the FPU are important. System performance improves dramatically with consistent finger placement. It is important to make sure that the position of the finger allows the FPU to record the unique features of the print. Follow the steps below for trouble-free fingerprint recognition. With the fingertip raised, position the finger so that the Ridge- Lock rests comfortably. Then, lower the finger onto the sensor and apply moderate pressure. The figure at right illustrates proper finger placement and the resulting image FPU operation - Instructions and regulations: • In view of our experience, we strongly recommend that each employee practices finger positioning on the sensor prior to actual enrolment! • Avoid using thumb and pinky fingers since they are typically awkward to position consistently on the sensor. • Place the higher joint of your finger on the ridge lock and lower your finger onto the sensor surface (make sure all other fingers are held straight to avoid creating an angle between the enrolled finger and the sensor surface - incorrect positioning). • When using an Authentec sensor sensitive to static electricity, touch the sensor's plastic casing (black) to discharge static electricity. Keep your finger steady. • Press your finger gently onto the panel, avoid excessive pressure as it will blur the print. 74
Page 77
-
• When using an Authentec sensor, make sure your finger is touching the sensor’s drive ring. • It is recommended that quality be 50% and content 90% at least. • Make sure you use the enrolled finger for verification! • If your finger is extremely dry, touch your forehead or the side of your nose before placing it on the sensor. • Do not use a wet/moist finger for scanning. Caution: For user’s convenience mount the terminal at a height of 1.4 meters (55.2”) (measured from the top end of the terminal to the floor) and at a distance of 15 cm (5.9”) from the right-side wall (closer to the sensor side).
Caution:
If it is impossible to sample an employee’s fingerprint, you can disable finger verification and revert to card or code mode instead.
Common mistakes Correct finger placement is a significant component for reliable fingerprint imaging. The following figures illustrate some common mistakes to avoid. • Sliding the fingertip into place instead of lowering it onto the sensor will cause distortion of the fingerprint and will degrade image quality. Keep the fingertip • Rotating the finger into position will also cause distortion of the fingerprint, • Placing your finger as if punching a button will not provide adequate information and will degrade system performance. Proper sensor height and angle along • Positioning the finger to one side and leaving a portion of the sensor exposed will degrade image quality. This figure demonstrates how poor finger placement degrades the image of the fingerprint. Notice how the core is well off- centre and • Placing the finger at an angle, as shown here, is another common mistake. Not placing the finger in an upright position will result in an unreadable image of the fingerprint.
75
Page 78
-
• Not using the Ridge- Lock may cause placing the finger in an incorrect position. This figure illustrates the user neglecting the Ridge- Lock and resulting fingerprint image. Notice how the core is well below centre and the sensor is not
76
Page 79
-
Reasons for Low Scores Some reasons for poor sampling results are listed below: Possible Reason Finger movement while sampling Finger not positioned properly
User might be pressing too hard User might not be pressing hard enough Finger too moist or wet
Finger too dry
Correction Instruct the user to remain still while Veriprint is sampling. With the fingertip raised, position the finger so that the RidgeLock rests comfortably within the first indentation of the finger. Next, lower the finger onto the sensor and apply very moderate pressure. Too much pressure on the sensor will blur the fingerprint ridges. Allow the user to apply gentle pressure while sampling. You must apply gentle pressure when enrolling. The fingerprint should lay flat upon the sensor surface. If the user washed their hands, but failed to completely dry the finger that is sampled, excessive moisture may cause the sample to be more difficult to obtain. Dry wet or moist fingers before sampling. Depending upon the geographical area, the season, and the skin type of the user, their fingerprint might be excessively rough or dry. Excessively dry skin may affect the sample quality. Try applying skin moisturizer a few minutes before enrolling to improve image quality.
77
Page 80
-
Appendix E Setting the terminal for Using POE (Power over Ethernet) PEO (Power over Ethernet) is a standard IEEE 802.3af. The standard provides the capability to deliver both power and data over standard Ethernet cabling. The standard provides 48 volts DC over two pairs of a four-pair cable at a maximum current of 350 mA for a maximum load power of 15.4 watts, although, after counting losses, only about 13 watts are available. 802.3af (PSEs) –”Power Source Equipments” can deliver their power on two ways, the first is over the spare lines and the second is over the data lines. The power will be connected to the (PDs) – “Powered Devices” just after an authentication process against the PSEs passed and the maximum power consumption of the PDs that can be connected to these PSEs must be less than ~12.9 - ~13Watt. For more details you refer to the following site: http://standards.ieee.org/getieee802/download/802.3af-2003.pdf
78
Page 81
-
6
Using POE
When using POE on the terminal you will need to make the following changes: CPU Board REV-D: JP104 should be shorted / P101 should have 7 PINs. Network cars type B: V2 should be compatible with POE. C6/R7/8/9/10 should be removed P2 Should be 7 PIN JP13 should be on (1-2) Net Card Type F: R1/R2 should be removed / P11 should be mounted / P2 should have 7 PINs / JP13 should be on (1-2). For more details please refer to the BOM & scheme file of these two boards. When using POE use the additional POE-DC2DC board using the Ag90120-S DC2DC module. The maximum output power is 9Watt, this means that the over-all power consumption of the POEterminal with this module is less than 9Watt. Other modules can be used if you need more power.
79