For the Synel SY-780A

Page 10

Terminal-Host Interfacing

SY-760 & SY-780/A Installation Manual

Male RJ45

Male RJ45 1

5.4 Step 1: Step 2: Step 3:

Step 4:

1

2

(-Tx, Rx)

(-Tx, Rx)

2

3

(+Tx, Rx)

(+Tx, Rx)

3

4

(Gnd)

(Gnd)

4

5

(TxD)

(TxD)

5

6

(RxD

(RxD

6

7

7

8

8

Terminal to the RS-232 PC port direct connection Open the connection box. Connect the TXD wire to the connection marked GR. Connect the RXD wire to the connection marked YL. Connect the ground wire to the connection marked RD. Close the connection box.

P1 RJ45

RxD

GND

8

TxD

Synel Industries Ltd.

Page 11

SY-760 & SY-780/A Installation Manual

6.

Maintenance

6.1

How to cause the memory to crash

Warning:

6.1.1

Maintenance

Must be performed by qualified personnel only! It requires working with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source.

Location of jumpers

Step 1: Unplug the terminal and make sure that it is off. The back-up battery automatically supplies power for approx. 15 seconds. Step 2: Unscrew and remove the front panel. Step 3: Remove the JP4 jumper from the 1-2 position to 2-3 position. Step 4: Reposition JP4 to (1-2). Step 5: Plug the terminal back into a power source and make sure that MEM CRASH reappears in the terminal display.

6.2

Formatting the memory if a crash occurs

If the memory crashes a CRASH message will appear. You will need to clear the terminal’s memory and return the terminal to the NO PROGRAMMING state according to the procedure below. Step 1: Press 6 times on the 0 key. Step 2: Press on the Enter key once. Press 3 times on the arrow (up) key. Step 3: Press twice on the arrow (down) key. Press 3 times on the arrow (up) key. The message CLEAR MEMORY? will appear on the display. Step 4: Press twice on the arrow (down) key. Step 5: The message MEMORY CLEARED will appear on the display. Step 6: You receive a NO PROG display. The terminal then will be in the Technician mode. The message on the display will alternate between TECHNICIAN MODE and the date and time in the following format: DD/DW hh:mm:ss where DW represents the day of the week. If you make an error on steps 3 through 6, the terminal will revert to the mode prior to step 3. If you are unable to complete this operation, exit technician mode by pressing the Enter key twice. Then begin again.

Synel Industries Ltd.

9

Page 12

Appendix - A

SY-760 & SY-780/A Installation Manual

Appendix - A External Connectors HOST RJ-45 (8 pin) Communication with Host computer Pin 1 2 3 4 5 6 7 8

Signal NC RS-485 (-TRX) RS-485 (+TRX) GND RS – 232 (TXD) RS – 232 (RXD) NC NC

Value

Remarks

0-5 Volt 0-5 Volt -12:+12Vdc -12:+12Vdc

Ser I RJ- 11 (6 Pin) Secondary serial channel for printer, scales or external PRintX Pin 1 2 3 4 5 6

Signal RS-232 TxD Transmit data GND RS-232 RxDReceive data RS - 232 TXD RS – 232 RXD VCC

Warning:

10

Value TX 0 RX

Remarks Finger print Finger print/Printer busy Printer Printer

5Volt

When connecting an external PRintX avoid connecting an internal PRintX!

Synel Industries Ltd.

Page 13

SY-760 & SY-780/A Installation Manual

NET Ethernet Pin 1 2 3 4 5 6 7 8 Pin 1 2 3 4 5 6/7/8

RJ-45 (Ethernet/Modem) (Set JP1, JP2 and JP3 for Ethernet)

Signal Transmit data Transmit data Receive data NC/Vin/Shield NC/Vin/Shield Receive data NC/GND/Shield NC/GND/Shield

Modem

Appendix - A

Value TX + TXRX +

Remarks

10Base-T/Power over LAN/100Base-T RX 10Base-T/Power over LAN/100Base-T 10Base-T/Power over LAN/100Base-T

(Set JP2 and JP3)

Signal NC NC NC Ring TIP NC

Value

Remarks

OP OP +

P10- External Reader 1(Magnetic/BarCode) RJ-45 (10 pin) (Optional) P11- External Reader 2(Magnetic /Bar code) RJ-45 (10 pin) Magnetic/Bar code/Wiegand readers Pin Signal 1 2 3 4 5 6 7 8 9 10

Data / (6-Wiegand) Led 1 Led 2 VCC GND Led 3 Clock (magnetic)/DATA 1 (Wiegand) DATA (0+Wiegand) VS Clock- (magnetic)/Data- (Wiegand)

Value Remarks For RS-422 signal only

Clock +, For RS-422 Data +, For RS-422 9v For RS-422 signal only

Note: Change JP18/19 accordingly.

Synel Industries Ltd.

11

Page 14

Appendix B - Jumpering

SY-760 & SY-780/A Installation Manual

Appendix B - Jumpering Printed side (PCB no. 770888-01-C)

12

Synel Industries Ltd.

Page 15 read from a scan by OCR; it may hold reading errors

SY-760 & SY-780/A Installation Manual Appendix B - Jumpering

Display Card o ° fa - } raf a I] ~ 7 o Ge) 6 - >| |e 2 = 1 ie ra e} 8C a os Fe 5 E

=] oie erewowrmererenereree o o c& Cc ie o

Synel Industries Ltd. 13

Page 16

Appendix B - Jumpering

SY-760 & SY-780/A Installation Manual

Ethernet - Modem No. Jumper 1 JP1

Description TU

Value 2-3 Ethernet 1-2 Modem Open Ethernet Close Modem Open Ethernet Close Modem

2

JP2

RU

3

JP3

RU

4

JP22/23/32 (1)NC/NC/NC--> modem/Ethernet 10Base-T

Default/Note 2-3 Ethernet Open - Ethernet Open - Ethernet default (1) Modem & Ethernet connected via JP1/2/3

(2)[(1-2),(2-3)]/[(1-2),(2-3)]/[(1-2)] Ethernet 10Base-T with Power over LAN (3)[(1-2),(2-3)]/[(1-2),(2-3)]/[(1-3)] Ethernet 100Base-T

PSD Programming No. Jumper Description 5 JP6 Jtag programming

Value Open - Normal work Closed - Programming

Default/Note Open

Miscellaneous No. Jumper Description 6 JP12 Watch Dog in 7

JP13

RTC

8

JP7

Battery

9

JP18

Reader 1 type

10

JP19

Reader 2 type

14

Value Open WDI Disable Closed - Normal WORK 1-2 Normal work 2-3 Calibration Open Battery OFF Closed Battery ON Wiegand - closed Other readers - Open Wiegand - closed Other readers - Open

Default/Note Closed Normal work Closed JP30 must be in (1-2) & JP31 must be closed JP30 must be in (1-2) & JP31 must be closed

Synel Industries Ltd.

Page 17

SY-760 & SY-780/A Installation Manual

Appendix B - Jumpering

No. Jumper Description 11 JP30/ Reader selection JP31

Default/Note Do not change!!

12

JP5

Disabled - NA

13

JP21

14

JP11

15

JP10

16

Value JP30 [1-2] JP31 [Closed] Tamper switch [1-2] - Enabled [2-3] - Disabled Connect (R2 Input) to [1-2] - External FPU the printer busy or to [2-3] - Printer busy the external FPU VCC

Testing current charging JP14/15/ UART selection 16/17

Synel Industries Ltd.

Closed - VCC ON Open - VCC OFF Closed - Normal work Open - Test current (1) (1-2)/(1-2)/(2-3)/(2-3) Default = value 1 u.CPU--> Host u.URT --> Printer (2) (2-3)/(2-3)/(1-2)/(1-2) u.CPU--> Printer u.URT --> Host

15

Page 18

Synel Industries Ltd. 2 Hamada St. POB 142, Yokneam Industrial Park, Israel, 20692 Tel: +972-4-959 6777 Fax: +972-4-959 0729 Site: www.synel-ind.com Tel-Aviv Branch Tel: +972 9 775 0400 UK Branch Tel: +44-181-900 9991 NA Branch Tel: +1-905-678 2605