For the Synel SY-780A
Page 10
Terminal-Host Interfacing
SY-760 & SY-780/A Installation Manual
Male RJ45
Male RJ45 1
5.4 Step 1: Step 2: Step 3:
Step 4:
1
2
(-Tx, Rx)
(-Tx, Rx)
2
3
(+Tx, Rx)
(+Tx, Rx)
3
4
(Gnd)
(Gnd)
4
5
(TxD)
(TxD)
5
6
(RxD
(RxD
6
7
7
8
8
Terminal to the RS-232 PC port direct connection Open the connection box. Connect the TXD wire to the connection marked GR. Connect the RXD wire to the connection marked YL. Connect the ground wire to the connection marked RD. Close the connection box.
P1 RJ45
RxD
GND
8
TxD
Synel Industries Ltd.
Page 11
SY-760 & SY-780/A Installation Manual
6.
Maintenance
6.1
How to cause the memory to crash
Warning:
6.1.1
Maintenance
Must be performed by qualified personnel only! It requires working with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source.
Location of jumpers
Step 1: Unplug the terminal and make sure that it is off. The back-up battery automatically supplies power for approx. 15 seconds. Step 2: Unscrew and remove the front panel. Step 3: Remove the JP4 jumper from the 1-2 position to 2-3 position. Step 4: Reposition JP4 to (1-2). Step 5: Plug the terminal back into a power source and make sure that MEM CRASH reappears in the terminal display.
6.2
Formatting the memory if a crash occurs
If the memory crashes a CRASH message will appear. You will need to clear the terminal’s memory and return the terminal to the NO PROGRAMMING state according to the procedure below. Step 1: Press 6 times on the 0 key. Step 2: Press on the Enter key once. Press 3 times on the arrow (up) key. Step 3: Press twice on the arrow (down) key. Press 3 times on the arrow (up) key. The message CLEAR MEMORY? will appear on the display. Step 4: Press twice on the arrow (down) key. Step 5: The message MEMORY CLEARED will appear on the display. Step 6: You receive a NO PROG display. The terminal then will be in the Technician mode. The message on the display will alternate between TECHNICIAN MODE and the date and time in the following format: DD/DW hh:mm:ss where DW represents the day of the week. If you make an error on steps 3 through 6, the terminal will revert to the mode prior to step 3. If you are unable to complete this operation, exit technician mode by pressing the Enter key twice. Then begin again.
Synel Industries Ltd.
9
Page 12
Appendix - A
SY-760 & SY-780/A Installation Manual
Appendix - A External Connectors HOST RJ-45 (8 pin) Communication with Host computer Pin 1 2 3 4 5 6 7 8
Signal NC RS-485 (-TRX) RS-485 (+TRX) GND RS – 232 (TXD) RS – 232 (RXD) NC NC
Value
Remarks
0-5 Volt 0-5 Volt -12:+12Vdc -12:+12Vdc
Ser I RJ- 11 (6 Pin) Secondary serial channel for printer, scales or external PRintX Pin 1 2 3 4 5 6
Signal RS-232 TxD Transmit data GND RS-232 RxDReceive data RS - 232 TXD RS – 232 RXD VCC
Warning:
10
Value TX 0 RX
Remarks Finger print Finger print/Printer busy Printer Printer
5Volt
When connecting an external PRintX avoid connecting an internal PRintX!
Synel Industries Ltd.
Page 13
SY-760 & SY-780/A Installation Manual
NET Ethernet Pin 1 2 3 4 5 6 7 8 Pin 1 2 3 4 5 6/7/8
RJ-45 (Ethernet/Modem) (Set JP1, JP2 and JP3 for Ethernet)
Signal Transmit data Transmit data Receive data NC/Vin/Shield NC/Vin/Shield Receive data NC/GND/Shield NC/GND/Shield
Modem
Appendix - A
Value TX + TXRX +
Remarks
10Base-T/Power over LAN/100Base-T RX 10Base-T/Power over LAN/100Base-T 10Base-T/Power over LAN/100Base-T
(Set JP2 and JP3)
Signal NC NC NC Ring TIP NC
Value
Remarks
OP OP +
P10- External Reader 1(Magnetic/BarCode) RJ-45 (10 pin) (Optional) P11- External Reader 2(Magnetic /Bar code) RJ-45 (10 pin) Magnetic/Bar code/Wiegand readers Pin Signal 1 2 3 4 5 6 7 8 9 10
Data / (6-Wiegand) Led 1 Led 2 VCC GND Led 3 Clock (magnetic)/DATA 1 (Wiegand) DATA (0+Wiegand) VS Clock- (magnetic)/Data- (Wiegand)
Value Remarks For RS-422 signal only
Clock +, For RS-422 Data +, For RS-422 9v For RS-422 signal only
Note: Change JP18/19 accordingly.
Synel Industries Ltd.
11
Page 14
Appendix B - Jumpering
SY-760 & SY-780/A Installation Manual
Appendix B - Jumpering Printed side (PCB no. 770888-01-C)
12
Synel Industries Ltd.
Page 15
SY-760 & SY-780/A Installation Manual Appendix B - Jumpering
Display Card o ° fa - } raf a I] ~ 7 o Ge) 6 - >| |e 2 = 1 ie ra e} 8C a os Fe 5 E
=] oie erewowrmererenereree o o c& Cc ie o
Synel Industries Ltd. 13
Page 16
Appendix B - Jumpering
SY-760 & SY-780/A Installation Manual
Ethernet - Modem No. Jumper 1 JP1
Description TU
Value 2-3 Ethernet 1-2 Modem Open Ethernet Close Modem Open Ethernet Close Modem
2
JP2
RU
3
JP3
RU
4
JP22/23/32 (1)NC/NC/NC--> modem/Ethernet 10Base-T
Default/Note 2-3 Ethernet Open - Ethernet Open - Ethernet default (1) Modem & Ethernet connected via JP1/2/3
(2)[(1-2),(2-3)]/[(1-2),(2-3)]/[(1-2)] Ethernet 10Base-T with Power over LAN (3)[(1-2),(2-3)]/[(1-2),(2-3)]/[(1-3)] Ethernet 100Base-T
PSD Programming No. Jumper Description 5 JP6 Jtag programming
Value Open - Normal work Closed - Programming
Default/Note Open
Miscellaneous No. Jumper Description 6 JP12 Watch Dog in 7
JP13
RTC
8
JP7
Battery
9
JP18
Reader 1 type
10
JP19
Reader 2 type
14
Value Open WDI Disable Closed - Normal WORK 1-2 Normal work 2-3 Calibration Open Battery OFF Closed Battery ON Wiegand - closed Other readers - Open Wiegand - closed Other readers - Open
Default/Note Closed Normal work Closed JP30 must be in (1-2) & JP31 must be closed JP30 must be in (1-2) & JP31 must be closed
Synel Industries Ltd.
Page 17
SY-760 & SY-780/A Installation Manual
Appendix B - Jumpering
No. Jumper Description 11 JP30/ Reader selection JP31
Default/Note Do not change!!
12
JP5
Disabled - NA
13
JP21
14
JP11
15
JP10
16
Value JP30 [1-2] JP31 [Closed] Tamper switch [1-2] - Enabled [2-3] - Disabled Connect (R2 Input) to [1-2] - External FPU the printer busy or to [2-3] - Printer busy the external FPU VCC
Testing current charging JP14/15/ UART selection 16/17
Synel Industries Ltd.
Closed - VCC ON Open - VCC OFF Closed - Normal work Open - Test current (1) (1-2)/(1-2)/(2-3)/(2-3) Default = value 1 u.CPU--> Host u.URT --> Printer (2) (2-3)/(2-3)/(1-2)/(1-2) u.CPU--> Printer u.URT --> Host
15
Page 18