Page 263

CLI Command Reference

Slovenia

SI

South Africa

ZA

South Korea

KR

Spain

ES

Sri Lanka

LK

Sweden

SE

Switzerland

CH

Taiwan

TW

Thailand

TH

Turkey

TR

UAE

AE

Ukraine

UA

United Kingdom

GB

United States

US

Uruguay

UY

Venezuela

VE

Vietnam

VN

8-31

A Ch: 36,40,44,48,52,56,60,64 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64,100,104,108,112,1 16,120,124,128,132,136,140 B Ch: 1-13 G Ch: 1-13 FH Ch: 54-76 A Ch: B Ch: 1-13 G Ch: 1-13 FH Ch: 47-73 A Ch: 36,40,44,48,52,56,60,64 B Ch: 1-2 G Ch: 1-2 FH Ch: 2-80 A Ch: B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64,100,104,108,112,1 16,120,124,128,132,136,140 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 52,56,60,64,100,104,108,112,116,120,124,1 28,132,136,140,149,153,157,161 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64,100,104,108,112,1 16,120,124,128,132,136,140 B Ch: 1-11 G Ch: 1-11 FH Ch: 2-80 A Ch: 36,40,44,48,52,56,60,64,149,153,157,161,1 65 B Ch: 1-13 G Ch: 1-13 FH Ch: 2-80 A Ch: B Ch: 1-11 G Ch: 1-11 FH Ch: 2-80 A Ch: 149,153,157,161,165 B Ch: 1-12 G Ch: 1-12 FH Ch: 2-80 A Ch:

WS5000.(Cfg)>

8.4.12 show chassis WS5000.(Cfg)> show chassis Description ----------CPU Temperature System Temperature System Fan (rpm) CPU Fan (rpm) System Fan 2 (rpm) System Fan 3 (rpm) System Fan 4 (rpm)

Curr Value ---------24 C 29 C OFF 16071 OFF OFF OFF

Max Value --------32 C 30 C 16463 -

Min Value --------24 C 29 C 16071 -

Notify Value -----------0 C 0 C None None None None None

Page 264

8-32

WS 5000 Series System Reference

8.4.13 show configaccess WS5000> show configaccess Configuration Access restriction details: Telnet access (CLI) : Disable. System access via SNMP : Enable. KDC configuration over remote console : Enable. KDC configuration through SNMP : Enable.

8.4.14 show ethernet WS5000> show ethernet Available EtherPorts are: Ethernet 1 Ethernet 2

8.4.15 show etherpolicy WS5000> show etherpolicy Available EtherPolicies are: 1. Default Ethernet Policy. 2. New Ethernet Port Policy. 3. eth1.

8.4.16 show events WS5000.(Cfg)> events Num Events --- -----1 License number change 2 Clock change 3 Packet discard [wrong NIC] 4 Packet discard [wrong VLAN] 5 AP adopt failure [general] 6 AP adopt failure [policy disallow] 7 AP adopt failure [acl disallow] 8 AP adopt failure [limit exceeded] 9 AP adopt failure [license disallow] 10 AP adopt failure [no image] 11 AP status [offline] 12 AP status [alert] 13 AP status [adopted] 14 AP status [reset] 15 AP config failed [no ESS] 16 AP max MU count reached 17 AP detected 18 Device msg dropped [info] 19 Device msg dropped [loadme] 20 Ether port connected 21 Ether port disconnected 22 MU assoc failed [ACL violation] 23 MU assoc failed 24 MU status [associated] 25 MU status [roamed]

Local Log --------Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

SNMP Trap --------Disabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Syslog Severity --------------Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

Page 265

CLI Command Reference

26 MU status [disassociated] Enabled 27 MU EAP auth failed Enabled 28 MU EAP auth success Enabled 29 MU Kerberos auth failed Enabled 30 MU Kerberos auth success Enabled 31 MU TKIP [decrypt failure] Enabled 32 MU TKIP [replay failure] Enabled 33 MU TKIP [MIC error] Enabled 34 WLAN auth success Enabled 35 WLAN auth failed Enabled 36 WLAN max MU count reached Enabled 37 Mgt user auth failed [radius] Disabled 38 Mgt user auth rejected Disabled 39 Mgt user auth success [radius] Enabled 40 Radius server timeout Enabled 41 KDC user [added] Enabled 42 KDC user [changed] Enabled 43 KDC user [deleted] Enabled 44 KDC DB replaced Enabled 45 KDC propagation failure Enabled 46 WPA counter-measures [active] Enabled 47 Primary lost heartbeat Enabled 48 Standby active Enabled 49 Primary internal failure [reset] Enabled 50 Standby internal failure [reset] Enabled 51 Standby auto-revert Enabled 52 Primary auto-revert Enabled 53 Auto channel select error Enabled 54 Emergency Policy [active] Enabled 55 Emergency Policy [deactivated] Enabled 56 Low flash space on switch Enabled 57 Miscellaneous debug events Disabled 58 HSB Starts Up Enabled 59 HSB Peer Connect Enabled 60 CPU/SYS Temp Notification Enabled 61 Access Changed Notification Enabled 62 Radio power is reduced [TPC] Enabled 63 Radar is detected [DFS] Enabled 64 Channel selected to avoid radar [DFS] Enabled 65 Switch to new channel [DFS] Enabled 66 Revert back to original channel [DFS] Enabled 67 Radio is suspended Enabled 68 Radio is resumed Enabled 69 Radio is moved to random channel Enabled 70 A new rogue AP is detected Enabled 71 A new approved AP is detected Enabled 72 WVPN certificate anomalies Enabled 73 WVPN Config/connection changes Enabled 74 RADIUS Accounting Log Disabled 75 RADIUS Server Status Enabled 76 Switch configuration changed Disabled 77 Tunnel Status change Enabled 78 NON IP packet received on Tunnel Enabled 79 RF Stats threshold crossed by a AP Enabled 80 RF Stats threshold crossed by a MU Enabled 81 RF Stats threshold crossed by a WLAN Enabled 82 RF Stats threshold crossed by Switch Enabled 83 AP is converted to sensor Enabled 84 Sensor is reverted back to AP Enabled 85 Failed to communicate to a sensor Enabled 86 Sensor is no longer responding to ping Enabled WS5000.(Cfg).Event>

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Disabled Enabled Enabled Enabled Disabled Enabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

8-33

Page 266

8-34

WS 5000 Series System Reference

8.4.17 show ftp WS5000> show ftp FTP Status:

Active.

8.4.18 show history WS5000. (Cfg)> show history Displaying last <300> executed commands... Command Name Command Context Date & Time ================================================================ show history (Cfg) Wed Dec 14 02:25:12 2005 show sensor

(Cfg)

Wed Dec 14 02:14:58 2005 show arp

(Cfg)

Wed Dec 14 02:12:23 2005 show history

(Cfg)

Wed Dec 14 02:11:04 2005 clear

(Cfg)

Wed Dec 14 02:11:00 2005 cfg

WS5000

Wed Dec 14 02:10:58 2005

8.4.19 show host You need to first add a syslog host in the WS5000.(Cfg).Event.Syslog context. Show host displays the syslog host added in the Events context, as mentoned above. WS5000> show host Host Name --------1 syslogHost

IP Address ---------192.192.4.111

Domain -----symbol.com

WS5000>

8.4.20 show https WS5000> show https Web based configuration (Applet) access by : https

8.4.21 show interfaces WS5000> show interfaces Interface information Access Ports -----------00:A0:F8:A2:91:7C [B] 00:A0:F8:5D:B9:0C [A] 00:A0:F8:6E:4A:7A [G] 00:A0:F8:6E:4A:7A [A] 00:A0:F8:BB:B3:6D [G]

Radio MAC --------00:A0:F8:A2:91:7C 00:A0:F8:60:BC:3D 00:A0:F8:6E:55:30 00:A0:F8:6E:4C:60 00:A0:F8:BB:F6:E8

Device MAC ---------00:A0:F8:A2:91:7C 00:A0:F8:5D:B9:0C 00:A0:F8:6E:4A:7A 00:A0:F8:6E:4A:7A 00:A0:F8:BB:B3:6D

Type ---B A G A G

Status -----Active Active Unavailable Unavailable Unavailable

Page 267

CLI Command Reference

00:A0:F8:BB:B3:6D [A] 00:A0:F8:BB:C7:6C

00:A0:F8:BB:B3:6D

A

8-35

Unavailable

Available EtherPorts are: Ethernet 1 Ethernet 2

8.4.22 show kdc WS5000> show kdc The system is configured as MASTER KDC. Kerberos Realm : realm1 Interface : ethernet1 User count (Active + deleted) : 0 Active users (MUs and WLANs) : 0 Slave KDCsIP AddressDomain -------------------------No entry available. List of all active KDC users (MUs & WLANs): No active Users available.

8.4.23 show knownap WS5000> show knownap Number of Access Points known to the Switch

: 5

8.4.24 show lan WS5000.(Cfg)> show lan LAN1 LAN information: LAN details... Name Description ep np allow deny NAT list:

: LAN1 : Public LAN : 1 : : https http telnet ftp :

8.4.25 show mu WS5000.(Cfg)> show mu # of MUs: 1 MU : MU_0 Type ---Data

ESSID: kris MAC Address ----------00:0F:3D:E9:A6:6A

RF Status Auth.Status --------- ----------Associated Authenticated

IP Address ---------157.235.208.93

Auth.Method ----------Open

WLAN ---Symbol Default

Enc.Method ---------Open

Broadcast Enc.Method -------------------Open

Page 268

8-36

WS 5000 Series System Reference

Access Port ----------00:A0:F8:5A:B3:1B [B] Power Mode ---------CAM Mode Statistics ---------Packets : Bytes :

Interface --------RF

VLAN Uptime --------NA 2267 sec Transmitted ----------34 4578

RSSI ---28

Cur.Rate -------11 Mbps

Time left --------0 sec Received -------2545 600

Supported Rates --------------1,2,5.5,11 Mbps

Last Activity ------------21 sec

Session Username ---------------NA

WS5000.(Cfg)>

8.4.26 show musummary WS5000.(Cfg)> show musummary # of MUs: 1 # MU-MAC-Address MU-IP AP-NAME ESSID 1 00:0F:3D:E9:A6:6A 157.235.208.93 00:A0:F8:5A:B3:1B [B] kris Associated(2327 sec.), Last Activity=21 sec., SNR=0 dB, #Roams=33

8.4.27 show np WS5000> show np Network Policy information Available Network Policies: 1. Default Network Policy. 2. NetVision_VoIP_Priority. 3. New Network Policy.

8.4.28 show po WS5000> show po Policy Object information...... Available Policies (PO): 1. NetVision Priority for RF. 2. NetVision Packet Marking for Ethernet. 3. New Input Policy. 4. New Output Policy.

8.4.29 show radius-server S5000.(Cfg)> show radius-server RADIUS authentication status: ----------------------------Network users (Web, Telnet, etc.) Local users (via serial port) Authenticate locally if RADIUS server refuses access

: Disable : Disable : Disable

Page 269

CLI Command Reference

Server -----Primary Secondary

Host Name/IP -----------Not defined Not defined

Port ---1812 1812

Retry ----3 3

8-37

Timeout ------5 5

8.4.30 show rfstats WS5000.(Cfg)> show rfstats Must provide AP index or AP name Syntax:show rfstats <radioname|radioindex>

{<radioname>|<radioindex>} where: <radioname|radioindex> {<radioname>|<radioindex>} or Radioindex. Example: show rfstats radioindex 1

8.4.31 show rfthreshold WS5000.(Cfg)> show rfthreshold Enter the Type. Displays Threshold Values for RF Stats Traps Syntax: show rfthreshold < ap|mu|switch > [CR] WS5000.(Cfg)> show rfthreshold ap Ap Threshold details : Status Min Packets for RF Traps Packets Per Second Throughput in Mbps Average Bit Speed in Mbps Percent of NUCast Packets Average Signal in Dbm Average Retries Percent of Dropped Packets Percent of Undecryp Packets Number of Associated MUs

: disabled : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set

WS5000.(Cfg)> show rfthreshold mu Mu Threshold details : Status Min Packets for RF Traps Packets Per Second Throughput in Mbps Average Bit Speed in Mbps Percent of NUCast Packets Average Signal in Dbm Average Retries Percent of Dropped Packets Percent of Undecryp Packets

: disabled : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set : Not Set

: adopted Radioname

Page 270

8-38

WS 5000 Series System Reference

WS5000.(Cfg)> show rfthreshold switch Switch Threshold details : Status Min Packets for RF Traps Packets Per Second Throughput in Mbps Associated MUs

: disabled : Not Set : Not Set : Not Set : Not Set

8.4.32 show rogueap WS5000.(Cfg)> show rogueap RogueAP configuration details: -----------------------------RogueAP Status MU Scan Status AP Scan Status Detector Scan Status MU Scan Interval(min.) AP Scan Interval(min.) Detector Scan Interval(min.)

: disable : disable : disable : disable : 0 : 0 : 0

8.4.33 show routes WS5000.(Cfg)> show routes Route Management: Kernel IP routing table Destination Gateway Genmask 157.235.208.0 0.0.0.0 255.255.255.0 10.1.1.0 0.0.0.0 255.255.255.0 0.0.0.0 157.235.208.246 0.0.0.0

8.4.34 show securitypolicy WS5000> show securitypolicy Available Security Policies: 1. Kerberos Default. 2. Default. 3. WEP40 Default. 4. WEP128 Default. 5. New WEP Security Policy.

8.4.35 show sensor WS5000. (Cfg)> show sensor Sensor functionality:Enabled AP300’s ------00:A0:F8:00:00:26 00:A0:F8:BF:8A:9F

Flags U U UG

Page 271

CLI Command Reference

Sensor AP’s ----------WS5000.(Cfg).sensor>

8.4.36 show snmpclients WS5000.(Cfg)> show snmpclients State ----1. Read/Write

Port ---161

IP Address ---------157.236.208.70

Community Name -------------symbol

WS5000.(Cfg)>

8.4.37 show snmpstatus WS5000> show snmpstatus SNMP details: ------------SNMP (deamon) Status SNMP Traps

: Enabled : Disabled

8.4.38 show ssh WS5000> show ssh SSH configurations details: --------------------------SSH Status : Enabled Version : V2 Port : 22 Session inactivity timeout

: 0 (Disabled)

8.4.39 show standby WS5000> show standby Standby Management: StandBy mode Standby Status State Failover Reason Standby Connectivity status Standby AutoRevert Mode Standby AutoRevert Delay

: Primary : Disable : Startup : : Not Connected : Disable : 15 Minutes

Interface (Ethernet) 1 ---------------------StandBy Heart-Beat MAC Heart-Beat status Received Heart-Beat

: Auto Discovery Enabled : Enable : No

8-39

Page 272

8-40

WS 5000 Series System Reference

Interface (Ethernet) 2 ---------------------StandBy Heart-Beat MAC Heart-Beat status Received Heart-Beat

: Auto Discovery Enabled : Disable : No

8.4.40 show switchpolicy WS5000> show switchpolicy Active Switch Policy name: Default Wireless Switch Policy Available Switch Policies: 1. Default Wireless Switch Policy.

8.4.41 show sysalerts WS5000.(Cfg)> show sysalerts Generating the log file.... Reading the log file..... [01/11/2006][12:23:00] Access Port (00:A0:F8:CD:C9:4A [B]) with MAC address "00. [01/11/2006][12:22:57] Access Port (00:A0:F8:CD:C9:4A [A]) with MAC address "00. [01/11/2006][12:21:18] Mobile Unit (00:0F:3D:E9:A6:6A) was associated to Access. [01/11/2006][12:21:04] Access Port (00:A0:F8:00:00:26 [A]) with MAC address "00. [01/11/2006][12:21:04] Access Port (00:A0:F8:00:00:26 [G]) with MAC address "00. [01/11/2006][12:20:33] ACS success. Setting Radio 00:A0:F8:B5:7C:A4 to channel . [01/11/2006][12:20:31] ACS success. Setting Radio 00:A0:F8:B5:3B:39 to channel . [01/11/2006][12:20:25] Adopted an Access Port "00:A0:F8:CD:C9:4A".

8.4.42 show syslog WS5000.(Cfg)> show syslog Remote Syslog Status:

Disable (Syslog Deamon is not running).

Local Syslog Status:

(Local Syslog Disabled).

Host ---sys alert ----x emerg ----x crit ---x err --x warning notice ------- -----x x

8.4.43 show system WS5000.(Cfg)> show system System information... System Name Description Switch Location Software Ver. Licensed to

: WS5000 : WS5000 Wireless Network : : 2.1.0.0-012B : Symbol Technologies info ---x debug ----x