The text of a manual · part 20 of 36
WS2000 Wireless Switch System Reference Guide, pages 188 to 197
Pages 188 to 197 of 346
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WS-2000
Page 188
7-44 WS2000 Wireless Switch System Reference Guide wlanipfpolicy set ipf-mode 1 enable set ipf-mode 1 disable set default incoming 1 allow set default outgoing 1 allow set ipf-mode 2 enable set ipf-mode 2 disable set default incoming 2 allow set default outgoing 2 allow set ipf-mode 3 enable set ipf-mode 3 disable set default incoming 3 allow set default outgoing 3 allow set ipf-mode 4 enable set ipf-mode 4 disable set default incoming 4 allow set default outgoing 4 allow set ipf-mode 5 enable set ipf-mode 5 disable set default incoming 5 allow set default outgoing 5 allow set ipf-mode 6 enable set ipf-mode 6 disable set default incoming 6 allow set default outgoing 6 allow set ipf-mode 7 enable set ipf-mode 7 disable set default incoming 7 allow set default outgoing 7 allow set ipf-mode 8 enable set ipf-mode 8 disable set default incoming 8 allow set default outgoing 8 allow / // TRUNK IP Filter Configuration / network wan trunkipfpolicy set ipf-mode enable set ipf-mode disable set default incoming allow set default outgoing allow / / network wan dyndns // DynDNS menu set mode disable
Page 189
Switch Administration 7-45 set username \0 set password \0 set hostname \0 / // WIDS Configuration network wids set mode disable set detect-window 10 / network wids set excess-op threshold mu probe-req 0 set excess-op threshold radio probe-req 0 set excess-op threshold switch probe-req 0 set excess-op filter-ageout probe-req 60 set excess-op threshold mu auth-assoc-req 0 set excess-op threshold radio auth-assoc-req 0 set excess-op threshold switch auth-assoc-req 0 set excess-op filter-ageout auth-assoc-req 60 set excess-op threshold mu deauth-disassoc-req 0 set excess-op threshold radio deauth-disassoc-req 0 set excess-op threshold switch deauth-disassoc-req 0 set excess-op filter-ageout deauth-disassoc-req 60 set excess-op threshold mu auth-fails 0 set excess-op threshold radio auth-fails 0 set excess-op threshold switch auth-fails 0 set excess-op filter-ageout auth-fails 60 set excess-op threshold mu crypto-replay-fails 0 set excess-op threshold radio crypto-replay-fails 0 set excess-op threshold switch crypto-replay-fails 0 set excess-op filter-ageout crypto-replay-fails 60 set excess-op threshold mu 80211-replay-fails 0 set excess-op threshold radio 80211-replay-fails 0 set excess-op threshold switch 80211-replay-fails 0 set excess-op filter-ageout 80211-replay-fails 60 set excess-op threshold mu decrypt-fails 0 set excess-op threshold radio decrypt-fails 0 set excess-op threshold switch decrypt-fails 0 set excess-op filter-ageout decrypt-fails 60 set excess-op threshold mu unassoc-frames 0 set excess-op threshold radio unassoc-frames 0 set excess-op threshold switch unassoc-frames 0 set excess-op filter-ageout unassoc-frames 60 set excess-op threshold mu eap-starts 0 set excess-op threshold radio eap-starts 0 set excess-op threshold switch eap-starts 0 set excess-op filter-ageout eap-starts 60 / network wids set anomaly-detect mode null-dst disable set anomaly-detect filter-ageout null-dst 60 set anomaly-detect mode same-src-dst disable set anomaly-detect filter-ageout same-src-dst 60 set anomaly-detect mode mcast-src disable set anomaly-detect filter-ageout mcast-src 60 set anomaly-detect mode weak-wep-iv disable set anomaly-detect filter-ageout weak-wep-iv 60
Page 190
7-46 WS2000 Wireless Switch System Reference Guide set anomaly-detect mode tkip-cntr-meas disable set anomaly-detect filter-ageout tkip-cntr-meas 60 set anomaly-detect mode invalid-frame-len disable set anomaly-detect filter-ageout invalid-frame-len 60 / / // Enhanced Rogue AP Scan configuration network wlan enhancedrogueap set mode disable set scaninterval 10 set scanduration 100 / // Mu Probe Table configuration network wlan muprobe set mode disable set size 200 / / passwd enc-admin b3 passwd enc-manager a11e00942773 / save
Page 191
Switch Administration 7-47
7.10 Updating Sensor Firmware WS2000 provides support for setting up AP300s as dedicated sensors. This feature enables updating the firmware for these APs without disturbing the switch settings. The following must be noted with respect to sensor firmware update: • The switch need not be restarted after a successful sensor firmware update. • APs that are converted as sensors after a sensor firmware update receive the new firmware. • APs that are sensors when the sensor firmware update is performed have to be reverted and re-converted. Select System Configuration --> Cfg/Firmware Mgt. --> Sensor Firmware Update from the left menu to set parameters to update the sensor firmware.
7.10.1 Setting Sensor Firmware Update Information To update the sensor firmware, perform the following steps: 1. Enter the sensor firmware file name in the Filename box. This is the name of the file that contains the sensor firmware. 2. Enter the IP address of the server where the sensor firmware is stored. Enter this IP address in the Server IP field. 3. Enter the user name for authentication with the file server. Enter this in the Username field. 4. Similarly, enter the password for the user name for authentication. Enter this in the Password field. 5. Optionally, provide the complete path to the sensor firmware file on the server. Enter the path in the Filepath(optional) field. 6. Select the bind interface from the Bind Interface drop down list. This interface is used to reach the FTP/ TFTP server for firmware update. Select, as the bind interface, the subnet that is configured as the local subnet for the VPN tunnel and on which the FTP/TFTP server resides.
Page 192
7-48 WS2000 Wireless Switch System Reference Guide
7. To restrict the maximum size of the sensor firmware image, use the Max size of sensor file. Use this value to restrict the file size for the sensor firmware file.
7.10.2 Updating the Sensor Firmware To update the sensor firmware, use the FTP or TFTP buttons on the screen. Select the appropriate server to update the sensor firmware from. A warning dialog appears.
Click Yes to proceed with sensor firmware update. Once the sensor firmware is updated, a status is shown in the Sensor Firmware Update screen.
7.11 Configuring SNMP The Simple Network Management Protocol (SNMP) facilitates the exchange of management information between network devices. SNMP allows an administrator to manage network performance, find and solve network problems, and plan for network growth. The WS2000 Wireless Switch includes SNMP management functions for gathering information from its network components, and communicating that information to specific users. There are four different SNMP screens. • Use the SNMP Access screen to define SNMP v1/v2c community definitions and SNMP v3 user definitions associated with access. • Use the SNMP Trap Configuration screen to configure to define SNMP v1/v2c community definitions and SNMP v3 user definitions associated with the traps themselves. Trap configuration depends on the network machine that receives the generated traps. • Use the SNMP Traps screen to enable system, network, SNMP, mobile unit, and Access Port traps. • Use the SNMP Rate Traps screen to enable traps by setting RF Rate thresholds.
Page 193
Switch Administration 7-49
Select System Configuration --> SNMP Access from the left menu to set up SNMP service.
7.11.1 Setting the SNMP Version Configuration The SNMP Access screen allows the administrator to define SNMP v1/v2c community definitions and SNMP v3 user definitions. SNMP v1 and v2c provide a strong network management system, but their security is relatively weak. SNMP v3 provides greatly enhanced security protocols. SNMP v3 encrypts transmissions and provides authentication for users generating requests.
7.11.1.1 Setting Up SNMP v1/v2c Community Definitions SNMP v1/v2c community definitions allow read-only or read/write access to switch-management information, as appropriate. The SNMP community, in this case, includes users whose IP addresses are specified on the SNMP Access Control subscreen. A read-only community string allows a remote device to retrieve information, while a read/write community string also allows a remote device to modify settings. Set up a read/write definition to facilitate full access by the administrator. 1. To create a new community definition, click the Add button in the SNMP v1/v2c Community Configuration area. 2. Type in a site-appropriate name for the community. 3. Click in the OID cell of the table. Either use the OID (Object Identifier) pull-down menu to select the default OID or type in an OID number into the field. (The format is in a numerical dot notation, and valid numbers can be found within the MIB.) If is selected, the community will have access to all the OIDs (SNMP parameters) in the SNMP Management Information Base (MIB) file. If a custom OID is entered, the administrator can allow access to specific OIDs in the MIB to certain communities. 4. Use the Access pull-down menu to specify read-only (R) access or read/write (RW) access for the community. Read-only access allows a remote device to retrieve switch information, while read/write access also allows a remote device to modify switch settings. 5. Continue to the Setting Up the Access Control List section in this document.
Page 194
7-50 WS2000 Wireless Switch System Reference Guide
7.11.1.2 Setting Up SNMP v3 Community Definitions Setting up the v3 user definition is very similar to the v1/v2c community definitions. The difference is the addition of a user security level and a user password. 1. To create a new SNMP v3 user definition, click the Add button in the SNMP v3 User Definitions area. 2. Specify a user name in the Username field. 3. Select a security level from the Security pull-down menu. Select from the following choices: noAuth
(no authorization) Allows the user to access SNMP without authorization or encryption
AuthNoPriv
(authorization without privacy) Requires the user to login, however no encryption is used
AuthPriv
(authorization with privacy) Requires the user to login and encryption is used
4. Click in the OID cell of the table. Either use the OID (Object Identifier) pull-down menu to select the default OID or type in an OID number into the field. (The format is in a numerical dot notation, and valid numbers can be found within the MIB.) If is selected, the community will have access to all the OIDs (SNMP parameters) in the SNMP Management Information Base (MIB) file. If a custom OID is entered, the administrator can allow access to specific OIDs in the MIB to certain communities. 5. Click the Password button in the cell and the Password Settings screen appears. 1.Select an Authentication Algorithm from the drop-down menu, either MD5 or SHA1. 2.Type in an Authentication Password. 3.Select a Privacy Algorithm from the drop-down menu. The options include: • DES • AES 128-bit 4.Type in a Privacy Password that matches the algorithm. 5.Click Ok, when done. 6. Use the Access pull-down menu to specify read-only (R) access or read/write (RW) access for the community. Read-only access allows a remote device to retrieve switch information, while read/write access also allows a remote device to modify switch settings. 7. Follow the directions for setting up the Access Control List (below).
Page 195
Switch Administration 7-51
7.11.2 Setting Up the Access Control List To set up the Access Control list as specified by a range of IP addresses, click the SNMP Access Control button at the bottom of the SNMP Access screen. The SNMP Access Control screen appears: 1. Click the Add button to create a new entry in the Access Control table. 2. Specify the IP address for the user(s) that have access. Enter an IP address only in the Starting IP Address column to specify an address for a single SNMP user. Enter both the Starting IP Address and Ending IP Address columns to specify a range of addresses for SNMP users. 3. Click Ok to save changes and return to the SNMP Access screen.
7.11.3 Setting the Trap Configuration To set the trap notification destination for SNMP, select System Configuration --> SNMP Access --> SNMP Trap Configuration from the left menu.
7.11.4 Setting the Trap Configuration for SNMP v1/v2c To set the trap notification destination for the SNMP v1/v2c servers, add one or more entries to SNMP v1/ v2c Trap Configuration table. 1. Click the Add button to add a new entry to the table. 2. Specify a Destination IP addresses for the systems that will receive notification when an SNMP trap is generated.
Page 196
7-52 WS2000 Wireless Switch System Reference Guide
3. Specify a destination User Datagram Protocol (UDP) port for receiving the traps that are sent by SNMP agents. UDP offers direct connection for sending and receiving datagrams over an IP network. 4. Specify a Community name that matches one of the community names added on the SNMP Access screen. 5. Select the appropriate SNMP Version (v1 or v2) from the pull-down menu for this particular SNMP server. 6. Click the Apply button to save the entries.
7.11.5 Setting the Trap Configuration for SNMP V3 To set the trap notification destination for the SNMP v3 servers, add one or more entries to SNMP v3 Trap Configuration table. 1. Click the Add button to add a new entry to the table. 2. Specify a Destination IP addresses for the systems that will receive notification when an SNMP trap is generated. 3. Specify a destination User Datagram Protocol (UDP) port for receiving the traps that are sent by SNMP agents. UDP offers direct connection for sending and receiving datagrams over an IP network. 4. Specify a Username that matches one of the user names added on the SNMP Access screen. 5. Specify a Security level from noAuth (no authorization required), AuthNoPriv (authorization without encryption), or AuthPriv (authorization with encryption). 6. Specify a password for the user. NOTE: When entering the same username on the SNMP Traps and SNMP Access screens, the password entered on the SNMP Traps page will overwrite the password entered on the SNMP Access page. To avoid this problem enter the same password on both pages. 7. Click the Apply button to save changes
7.11.6 Selecting Traps The SMNP Trap screen allow you to specify the types of network events that generate traps, and who to notify regarding the events. SNMP traps are generated according to predefined types of network events that are considered important to manage. This information is asynchronously reported to the switch’s SNMP network-management system by switch-managed entities. Notification is sent to the responsible individuals whose IP addresses are listed for trap notification.
Page 197
Switch Administration 7-53
1. To set the SNMP traps, select System Configuration --> SNMP Access --> SNMP Traps from the left menu.
2. Check the type of traps to enable the generation of notification events. Trap Category System Traps
Network Traps
Trap Name
Generates a Trap whenever…
System Cold Start
The switch’s router reinitializes while transmitting, possibly altering the agent’s configuration or protocol entity implementation.
Configuration Changes
SNMP access or management functions are reconfigured.
User Login Failure
A user fails to successfully login from the CLI or Applet.
Admin Password Change
A change is made to the Admin user password.
Low Compact Flash Memory
The memory in the Compact Flash card in the system falls below the amount specified.
Physical port status change
The status changes for one of the ports on the front of the WS2000, such as if a device is plugged into or unplugged from the switch, or if the link is lost between the switch and the connected device.
Interface Status Change
An interface on the switches status changes from its configured state.
DynDNS Update
If Dynamic DNS services are configured on the WAN a new trap is set when there is a Dynamic DNS update.
Denial of service (DOS) attempts
A Denial of Service attack is detected by the switch’s firewall. A new trap will be sent at the interval specified until the attack has stopped.