Page 33

Chapter 3 Maintenance and Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).

Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.

• Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window.

Page 34

3-2

Symbol DS6608 Product Reference Guide

Troubleshooting Table 3-1 Troubleshooting

Problem The aiming pattern does not appear when pressing the trigger.

Possible Causes

Possible Solutions

No power to the digital scanner.

If the configuration requires a power supply, re-connect the power supply.

Incorrect host interface cable is used.

Connect the correct host interface cable.

Interface/power cables are loose.

Re-connect cables.

Digital scanner is disabled.

For Synapse or IBM 468x mode, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.

If using RS-232 Nixdorf B mode, CTS is not asserted.

Assert CTS line.

Aiming pattern is disabled.

Enable the aiming pattern. See Decode Aiming Pattern on page 5-4.

Scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.

The USB bus may put the digital scanner in a state where power to the digital scanner is cycled on and off more than once.

Normal during host reset.

Digital scanner emits aiming pattern, but does not decode the bar code.

Digital scanner is not programmed for the correct bar code type.

Program the digital scanner to read that type of bar code. See Chapter 13, Symbologies.

Bar code symbol is unreadable.

Scan test symbols of the same bar code type to determine if the bar code is defaced.

The symbol is not completely inside aiming pattern.

Move the symbol completely within the aiming pattern.

Digital scanner has not completed USB initialization.

Wait several seconds and scan again.

Digital scanner emits 4 short high beeps during decode attempt.

Page 35

Maintenance and Technical Specifications

3-3

Table 3-1 Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

Digital scanner decodes bar code, but does not transmit the data to the host.

Digital scanner is not programmed for the correct host type.

Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.

Interface cable is loose.

Re-connect the cable.

If 4 long low beeps are heard, a transmission error occurred.

Set the digital scanner's communication parameters to match the host's setting.

If 5 low beeps are heard, a conversion or format error occurred.

Configure the digital scanner's conversion parameters properly.

If lo/hi/lo beeps are heard, an invalid ADF rule is detected.

Program the correct ADF rules.

If hi/lo beeps are heard, the digital scanner is buffering Code 39 data.

Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.

Digital scanner is not programmed to work with the host.

Scan the appropriate host type programming bar code.

Host displays scanned data incorrectly.

For RS-232, set the digital scanner's communication parameters to match the host's settings. For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key. Program the proper editing options (e.g., UPC-E to UPC-A Conversion). Digital scanner emits hi/hi/hi/Lo beeps when not in use.

RS-232 receive error.

Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.

Digital scanner emits lo/hi beeps during programming.

Input error or Cancel bar code was scanned.

Scan the correct numeric bar codes within range for the parameter programmed.

Digital scanner emits lo/hi/lo/hi beeps during programming.

Out of ADF parameter storage space.

Erase all rules and re-program with shorter rules.

Out of Synapse parameter storage space.

Scan Set Synapse Defaults bar code for cables no longer in use and re-program the digital scanner for the current host interface.

Page 36

3-4

Symbol DS6608 Product Reference Guide

Table 3-1 Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

Digital scanner emits lo/hi/lo beeps.

Clearing Code 39 buffer.

Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.

Digital scanner emits a power-up beep after changing USB host type.

The USB bus re-established power to the digital scanner.

Normal when changing USB host type.

Digital scanner emits one high beep when not in use.

In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.

Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.

NOTE

If after performing these checks the digital scanner still experiences problems, contact the distributor or contact Motorola Enterprise Mobility Support. See page xv for contact information

Technical Specifications Table 3-2 Technical Specifications

Item

Description

Power Requirements

5 VDC + / - 10% @ approximately 220 mA RMS (nominal), 500 mA (max)

Power Source

Depending on host:

• Host powered • External power supply, 5.2 V nominal Decode Capability

UPC/EAN, UPC/EAN with supplementals, UCC/EAN, JAN 8 & 13, 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, IATA 2 of 5, Code 128, Code 93, MSI, Code 11, Code 32, Coupon Code, Bookland EAN, GS1 DataBar, US Postnet, US Planet, UK Postal, Japan Postal, Australia Postal, Dutch Postal, Composite Codes, PDF417, MicroPDF, Maxicode, Data Matrix (ECC 200), QR Code.

Beeper Operation

User-selectable: enable, disable

Beeper Volume

User-selectable: three levels

Beeper Tone

User-selectable: three tones

Yaw Tolerance

± 50° from normal

Pitch Tolerance

± 60° from normal

Roll Tolerance

± 180° from normal

Page 37

Maintenance and Technical Specifications

Table 3-2 Technical Specifications (Continued)

Item

Description

Print Contrast Minimum

25% minimum reflectance differential, measured at 650 nm.

Ambient Light Immunity

10,000 Ft Candles (107,600 Lux)

Durability

6 ft (1.8 m) drop to concrete

Operating Temperature

32° to 122° F (0° to 50° C)

Storage Temperature

-40° to 158° F (-40° to 70° C)

Humidity

5% to 95% (non-condensing)

Weight (without cable)

6.4 oz. (181.4 g)

Dimensions: Height Width Depth

6.55 in. (16.64 cm) 2.82 in. (7.16 cm) 4.72 in. (11.99 cm)

Laser

650nm laser diode

Laser Classifications

IEC 825-1 Class 2

ESD

15 kV area discharge 8 kV contact discharge

Minimum Element Width

5 mil (0.127 mm)

Interfaces Supported

RS-232, Keyboard Wedge, Wand Emulation, Scanner Emulation, IBM 468X/469X, USB, Synapse

Electrical Safety

UL1950, CSA C22.2 No.950. EN60950/IC950

Input Transient Protection

IEC 1000-4-(2,3,4,5,6,11)

EMI

FCC Part 15 Class B, ICES-003 Class B European Union EMC Directive, Japan VCCI/MITI/Dentori

3-5

Page 38

3-6

Symbol DS6608 Product Reference Guide

Digital Scanner Signal Descriptions Bottom of digital scanner

Cable interface port

Pin 1

Pin 10

Interface cable modular connector

Figure 3-1 Digital Scanner Cable Pinouts

The signal descriptions in Table 3-3 apply to the connector on the digital scanner and are for reference only. Table 3-3 Digital Scanner Signal Pin-outs

Pin

IBM

Synapse

RS-232

Keyboard Wedge

Wand

USB

Scanner Emulation

1

Reserved

SynClock

Reserved

Reserved

Reserved

Jump to Pin 6

DBP

2

Power

Power

Power

Power

Power

Power

Power

3

Ground

Ground

Ground

Ground

Ground

Ground

Ground

4

IBM_A(+)

Reserved

TxD

KeyClock

DBP

Reserved

SOS

5

Reserved

Reserved

RxD

TermData

CTS

D+

Decode

6

IBM_B(-)

SynData

RTS

KeyData

RTS

Jump to Pin 1

Trigger

7

Reserved

Reserved

CTS

TermClock

Reserved

D-

Enable

8

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

9

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

10

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved