Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 42 of 50

Symbol DS6608 Product Reference Guide: Standard Default Parameters

Pages 341 to 348 of 396, from Symbol DS6608 Product Reference Guide

The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol VS-6608

Page 341

Appendix A Standard Default Parameters

Table A-1

Standard Default Parameters Table Parameter

Parameter Number

Default

Page Number

User Preferences Set Default Parameter

All Defaults

4-3

Parameter Scanning

ECh

Enable

4-3

Beeper Tone

91h

Medium

4-4

Beeper Volume

8Ch

High

4-5

Power Mode

80h

Continuous On

4-5

Time Delay to Low Power Mode

92h

1 Minute

4-6

Trigger Mode

8Ah

Auto Aim

4-8

Picklist Mode

F0h 92h

Disabled Always

4-9

Decode Session Timeout

88h

9.9 Sec

4-10

Timeout Between Decodes, Same Symbol

89h

0.6 Sec

4-10

Beep After Good Decode

38h

Enable

4-11

Decoding Illumination

F0h 2Ah

Enable

5-3

Decode Aiming Pattern

F0h 32h

Enable

5-4

Decoding Preferences

1

User selection is required to configure this interface and this is the most common selection.

Page 342

A-2

Symbol DS6608 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Keyboard Wedge Host Parameters Keyboard Wedge Host Type

IBM PC/AT& IBM PC Compatibles1

6-4

Country Types (Country Codes)

North American

6-5

Ignore Unknown Characters

Transmit

6-7

Keystroke Delay

No Delay

6-7

Intra-Keystroke Delay

Disable

6-8

Alternate Numeric Keypad Emulation

Disable

6-8

Caps Lock On

Disable

6-9

Caps Lock Override

Disable

6-9

Convert Wedge Data

No Convert

6-10

Function Key Mapping

Disable

6-10

FN1 Substitution

Disable

6-11

Send and Make Break

Send

6-11

RS-232 Host Types

Standard1

7-6

Baud Rate

9600

7-7

Parity Type

None

7-9

Stop Bit Select

1 Stop Bit

7-10

Data Bits

8-Bit

7-10

Check Receive Errors

Enable

7-10

Hardware Handshaking

None

7-12

Software Handshaking

None

7-14

Host Serial Response Time-out

2 Sec

7-15

RTS Line State

Low RTS

7-16

Beep on <BEL>

Disable

7-16

Intercharacter Delay

0 msec

7-17

Nixdorf Beep/LED Options

Normal Operation

7-18

RS-232 Host Parameters

1

User selection is required to configure this interface and this is the most common selection.

Page 343

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Ignore Unknown Characters

Parameter Number

Default

Page Number

Send Bar Code

7-18

USB Device Type

HID Keyboard Emulation

8-4

USB Country Keyboard Types (Country Codes)

North American

8-5

USB Keystroke Delay

No Delay

8-7

USB CAPS Lock Override

Disable

8-7

USB Ignore Unknown Characters

Enable

8-8

Emulate Keypad

Disable

8-8

Emulate Keypad with Leading Zero

Disable

8-9

USB Keyboard FN1 Substitution

Disable

8-9

Function Key Mapping

Disable

8-10

Simulated Caps Lock

Disable

8-10

Convert Case

No Case Conversion

8-11

Port Address

None Selected

9-4

Convert Unknown to Code 39

Disable

9-5

Wand Emulation Host Types

Symbol OmniLink Interface Controller1

10-4

Leading Margin

80 msec

10-5

Polarity

Bar High/Margin Low

10-6

Ignore Unknown Characters

Ignore

10-6

Convert All Bar Codes to Code 39

Disable

10-7

Convert Code 39 to Full ASCII

Disable

10-8

Beep Style

Beep on Successful Transmit

11-4

Parameter Pass-Through

Parameter Process and Pass Through

11-5

Convert Newer Code Types

Convert Newer Code Types

11-6

USB Host Parameters

IBM 468X/469X Host Parameters

Wand Emulation Host Parameters

Undecoded Scanner Emulation

1User selection is required to configure this interface and this is the most common selection.

A-3

Page 344

A-4

Symbol DS6608 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Module Width

20 µs

11-6

Convert All Bar Codes to Code 39

Do Not Convert to Code 39

11-7

Code 39 Full ASCII Conversion

Disable

11-7

Transmission Timeout

3 seconds

11-8

Ignore Unknown Characters

Ignore Unknown Characters

11-9

Leading Margin

2 ms

11-10

Check for Decode LED

Check for Decode LED

11-11

None1

12-1

123Scan Configuration Tool 123Scan Configuration UPC/EAN UPC-A

01h

Enable

13-7

UPC-E

02h

Enable

13-7

UPC-E1

0Ch

Disable

13-8

EAN-8/JAN 8

04h

Enable

13-8

EAN-13/JAN 13

03h

Enable

13-9

Bookland EAN

53h

Disable

13-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

13-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

F1h 43h F1h 44h

UPC/EAN/JAN Supplemental Redundancy

50h

10

13-13

Transmit UPC-A Check Digit

28h

Enable

13-14

Transmit UPC-E Check Digit

29h

Enable

13-14

Transmit UPC-E1 Check Digit

2Ah

Enable

13-15

UPC-A Preamble

22h

System Character

13-16

UPC-E Preamble

23h

System Character

13-17

UPC-E1 Preamble

24h

System Character

13-18

Convert UPC-E to A

25h

Disable

13-19

1

13-13

User selection is required to configure this interface and this is the most common selection.

Page 345

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Convert UPC-E1 to A

26h

Disable

13-19

EAN-8/JAN-8 Extend

27h

Disable

13-20

Bookland ISBN Format

F1h 40h

ISBN-10

13-21

UCC Coupon Extended Code

55h

Disable

13-22

Code 128

08h

Enable

13-22

UCC/EAN-128

0Eh

Enable

13-23

ISBT 128

54h

Enable

13-23

Code 39

00h

Enable

13-24

Trioptic Code 39

0Dh

Disable

13-24

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

13-25

Code 32 Prefix

E7h

Disable

13-25

Set Length(s) for Code 39

12h 13h

2 to 55

13-26

Code 39 Check Digit Verification

30h

Disable

13-28

Transmit Code 39 Check Digit

2Bh

Disable

13-28

Code 39 Full ASCII Conversion

11h

Disable

13-29

Buffer Code 39

71h

Disable

13-29

Code 93

09h

Disable

13-32

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

13-33

Code 11

0Ah

Disable

13-35

Set Lengths for Code 11

1Ch 1Dh

4 to 55

13-35

Code 11 Check Digit Verification

34h

Disable

13-37

Transmit Code 11 Check Digit(s)

2Fh

Disable

13-38

Code 128

Code 39

Code 93

Code 11

1

User selection is required to configure this interface and this is the most common selection.

A-5

Page 346

A-6

Symbol DS6608 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF)

06h

Enable

13-38

Set Lengths for I 2 of 5

16h 17h

14

13-39

I 2 of 5 Check Digit Verification

31h

Disable

13-41

Transmit I 2 of 5 Check Digit

2Ch

Disable

13-41

Convert I 2 of 5 to EAN 13

52h

Disable

13-42

Discrete 2 of 5

05h

Disable

13-43

Set Length(s) for D 2 of 5

14h 15h

12

13-43

Codabar

07h

Disable

13-45

Set Lengths for Codabar

18h 19h

5 to 55

13-45

CLSI Editing

36h

Disable

13-47

NOTIS Editing

37h

Disable

13-47

MSI

0Bh

Disable

13-48

Set Length(s) for MSI

1Eh 1Fh

4 to 55

13-48

MSI Check Digits

32h

One

13-50

Transmit MSI Check Digit

2Eh

Disable

13-50

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

13-51

US Postnet

59h

Enable

13-53

US Planet

5Ah

Enable

13-53

Transmit US Postal Check Digit

5Fh

Enable

13-54

UK Postal

5Bh

Enable

13-54

Transmit UK Postal Check Digit

60h

Enable

13-55

Japan Postal

F0h 22h

Enable

13-55

Australian Postal

F0h 23h

Enable

13-56

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Postal Codes

1User selection is required to configure this interface and this is the most common selection.

Page 347

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Dutch Postal

F0h 46h

Enable

13-56

4State Postal

F1h 50h

Disable

13-57

GS1 DataBar-14

F0h 52h

Enable

13-58

GS1 DataBar Limited

F0h 53h

Enable

13-58

GS1 DataBar Expanded

F0h 54h

Enable

13-59

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

13-59

Composite CC-C

F0h 55h

Disable

13-60

Composite CC-A/B

F0h 56h

Disable

13-60

Composite TLC-39

F0h 73h

Disable

13-61

UPC Composite Mode

F0h 58h

Always Linked

13-62

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

13-63

GS1 DataBar

Composite

UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes

F0h ABh

Disable 13-63

2D Symbologies PDF417

0Fh

Enable

13-64

MicroPDF417

E3h

Disable

13-64

Code 128 Emulation

7Bh

Disable

13-65

Data Matrix

F0h 24h

Enable

13-66

DataMatrix Inverse

F1h 4Ch

Regular

13-67

Maxicode

F0h 26h

Enable

13-68

QR Code

F0h 25h

Enable

13-68

MicroQR

F1h 3Dh

Enable

13-69

QR Inverse

F1h 4Bh

Regular

13-69

Aztec

F1h 3Eh

Enable

13-70

Aztec Inverse

F1h 4Dh

Regular

13-70

1

User selection is required to configure this interface and this is the most common selection.

A-7

Page 348

A-8

Symbol DS6608 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Symbology-Specific Security Levels Redundancy Level

4Eh

1

13-71

Security Level

4Dh

1

13-73

Intercharacter Gap Size

F0h 7Dh

Normal

13-74

Report Version

13-74

Macro PDF Flush Macro PDF Buffer

13-75

Abort Macro PDF Entry

13-75

Miscellaneous Scanner Options Transmit Code ID Character

2Dh

None

14-3

Prefix Value

63h, 69h

7013 <CR><LF>

14-4

Suffix 1 Value Suffix 2 Value

62h, 68h 64h, 6Ah

7013 <CR><LF>

14-4

Scan Data Transmission Format

EBh

Data as is

14-5

FN1 Substitution Values

67h, 6Dh

Set

14-7

Transmit “No Read” Message

5Eh

Disable

14-8

Synapse Interface

F0h ACh

Standard

14-9

1