Page 151
Chapter 12 123Scan Introduction 123Scan is a Windows®-based utility that programs the digital scanner with all parameters including Advanced Data Formatting (ADF) Rules. An ADF rule modifies bar code data before it is sent to the host to ensure compatibility between bar coded data and the host application. Digital scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility. Digital scanner programming is saved in a file for electronic distribution. The 123Scan program includes a help file.
Communication with 123Scan To communicate with the 123Scan program which runs on a host computer running a Windows operating system, use an RS-232 cable to connect the digital scanner to the host computer (see Connecting an RS-232 Interface on page 7-2). 123Scan requirements:
• Host computer with Windows 98, Windows NT, Windows 2000, or Windows XP • Digital scanner • RS-232 cable.
123Scan Parameter To communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto the host computer, and scan the bar code below. Refer to 123Scan instructions for programming the digital scanner. Scan the bar code below to enable the 123Scan interface on the digital scanner.
123Scan Configuration
Page 152
12 - 2 Symbol DS6608 Product Reference Guide
Page 153
Chapter 13 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. The digital scanner is shipped with the settings shown in the Symbology Default Table on page 13-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down. NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan *Set All Defaults on page 4-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*Enable UPC-A
Feature/Option
Page 154
13 - 2 Symbol DS6608 Product Reference Guide
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 13-14. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults Table 13-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 13-7. NOTE
See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.
Table 13-1 Symbology Default Table
Parameter
Parameter Number
Default
Page Number
UPC/EAN UPC-A
01h
Enable
13-7
UPC-E
02h
Enable
13-7
UPC-E1
0Ch
Disable
13-8
EAN-8/JAN 8
04h
Enable
13-8
EAN-13/JAN 13
03h
Enable
13-9
Bookland EAN
53h
Disable
13-9
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
13-10
User-Programmable Supplementals Supplemental 1: Supplemental 2:
F1h 43h F1h 44h
UPC/EAN/JAN Supplemental Redundancy
50h
10
13-13
Transmit UPC-A Check Digit
28h
Enable
13-14
Transmit UPC-E Check Digit
29h
Enable
13-14
13-13
Page 155
Symbologies 13 - 3
Table 13-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Transmit UPC-E1 Check Digit
2Ah
Enable
13-15
UPC-A Preamble
22h
System Character
13-16
UPC-E Preamble
23h
System Character
13-17
UPC-E1 Preamble
24h
System Character
13-18
Convert UPC-E to A
25h
Disable
13-19
Convert UPC-E1 to A
26h
Disable
13-19
EAN-8/JAN-8 Extend
27h
Disable
13-20
Bookland ISBN Format
F1h 40h
ISBN-10
13-21
UCC Coupon Extended Code
55h
Disable
13-22
Code 128
08h
Enable
13-22
UCC/EAN-128
0Eh
Enable
13-23
ISBT 128
54h
Enable
13-23
Code 39
00h
Enable
13-24
Trioptic Code 39
0Dh
Disable
13-24
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
13-25
Code 32 Prefix
E7h
Disable
13-25
Set Length(s) for Code 39
12h 13h
2 to 55
13-26
Code 39 Check Digit Verification
30h
Disable
13-28
Transmit Code 39 Check Digit
2Bh
Disable
13-28
Code 39 Full ASCII Conversion
11h
Disable
13-29
Buffer Code 39
71h
Disable
13-30
Code 93
09h
Disable
13-32
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
13-33
Code 11
0Ah
Disable
13-35
Set Lengths for Code 11
1Ch 1Dh
4 to 55
13-35
Code 11 Check Digit Verification
34h
Disable
13-37
Code 128
Code 39
Code 93
Code 11
Page 156
13 - 4 Symbol DS6608 Product Reference Guide
Table 13-1 Symbology Default Table (Continued)
Parameter Transmit Code 11 Check Digit(s)
Parameter Number
Default
Page Number
2Fh
Disable
13-38
Interleaved 2 of 5 (ITF)
06h
Enable
13-38
Set Lengths for I 2 of 5
16h 17h
14
13-39
I 2 of 5 Check Digit Verification
31h
Disable
13-41
Transmit I 2 of 5 Check Digit
2Ch
Disable
13-41
Convert I 2 of 5 to EAN 13
52h
Disable
13-42
Discrete 2 of 5
05h
Disable
13-43
Set Length(s) for D 2 of 5
14h 15h
12
13-43
Codabar
07h
Disable
13-45
Set Lengths for Codabar
18h 19h
5 to 55
13-45
CLSI Editing
36h
Disable
13-47
NOTIS Editing
37h
Disable
13-47
MSI
0Bh
Disable
13-48
Set Length(s) for MSI
1Eh 1Fh
4 to 55
13-48
MSI Check Digits
32h
One
13-50
Transmit MSI Check Digit
2Eh
Disable
13-50
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
13-51
Inverse 1D
F1h 4Ah
Regular
13-52
US Postnet
59h
Enable
13-53
US Planet
5Ah
Enable
13-53
Transmit US Postal Check Digit
5Fh
Enable
13-54
UK Postal
5Bh
Enable
13-54
Transmit UK Postal Check Digit
60h
Enable
13-55
Japan Postal
F0h 22h
Enable
13-55
Australian Postal
F0h 23h
Enable
13-56
Interleaved 2 of 5 (ITF)
Discrete 2 of 5 (DTF)
Codabar (NW - 7)
MSI
Postal Codes
Page 157
Symbologies 13 - 5
Table 13-1 Symbology Default Table (Continued)
Parameter
Parameter Number
Default
Page Number
Dutch Postal
F0h 46h
Enable
13-56
4State Postal
F1h 50h
Disable
13-57
GS1 DataBar-14
F0h 52h
Enable
13-58
GS1 DataBar Limited
F0h 53h
Enable
13-58
GS1 DataBar Expanded
F0h 54h
Enable
13-59
Convert GS1 DataBar to UPC/EAN
F0h 8Dh
Disable
13-59
Composite CC-C
F0h 55h
Disable
13-60
Composite CC-A/B
F0h 56h
Disable
13-60
Composite TLC-39
F0h 73h
Disable
13-61
UPC Composite Mode
F0h 58h
Always Linked
13-62
Composite Beep Mode
F0h 8Eh
Beep As Each Code Type is Decoded
13-63
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes
F0h ABh
Disable
13-63
PDF417
0Fh
Enable
13-64
MicroPDF417
E3h
Disable
13-64
Code 128 Emulation
7Bh
Disable
13-65
Data Matrix
F0h 24h
Enable
13-66
DataMatrix Inverse
F1h 4Ch
Regular
13-67
Maxicode
F0h 26h
Enable
13-68
QR Code
F0h 25h
Enable
13-68
MicroQR
F1h 3Dh
Enable
13-69
QR Inverse
F1h 4Bh
Regular
13-69
Aztec
F1h 3Eh
Enable
13-70
Aztec Inverse
F1h 4Dh
Regular
13-70
Redundancy Level
4Eh
1
13-71
Security Level
4Dh
1
13-73
GS1 DataBar
Composite
2D Symbologies
Symbology-Specific Security Levels
Page 158
13 - 6 Symbol DS6608 Product Reference Guide
Table 13-1 Symbology Default Table (Continued)
Parameter Intercharacter Gap Size Report Version
Parameter Number F0h 7Dh
Default Normal
Page Number 13-74 13-74
Macro PDF Flush Macro PDF Buffer
13-75
Abort Macro PDF Entry
13-75
Page 159
Symbologies 13 - 7
UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below.
*Enable UPC-A (01h)
Disable UPC-A (00h)
Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.
*Enable UPC-E (01h)
Disable UPC-E (00h)
Page 160
13 - 8 Symbol DS6608 Product Reference Guide
Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE
UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
Enable UPC-E1 (01h)
*Disable UPC-E1 (00h)
Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
*Enable EAN-8/JAN-8 (01h)
Disable EAN-8/JAN-8 (00h)