Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 22 of 50

Symbol DS6608 Product Reference Guide, pages 151 to 160

Pages 151 to 160 of 396: 123Scan; Symbologies

The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol VS-6608

Page 151

Chapter 12 123Scan Introduction 123Scan is a Windows®-based utility that programs the digital scanner with all parameters including Advanced Data Formatting (ADF) Rules. An ADF rule modifies bar code data before it is sent to the host to ensure compatibility between bar coded data and the host application. Digital scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility. Digital scanner programming is saved in a file for electronic distribution. The 123Scan program includes a help file.

Communication with 123Scan To communicate with the 123Scan program which runs on a host computer running a Windows operating system, use an RS-232 cable to connect the digital scanner to the host computer (see Connecting an RS-232 Interface on page 7-2). 123Scan requirements:

• Host computer with Windows 98, Windows NT, Windows 2000, or Windows XP • Digital scanner • RS-232 cable.

123Scan Parameter To communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto the host computer, and scan the bar code below. Refer to 123Scan instructions for programming the digital scanner. Scan the bar code below to enable the 123Scan interface on the digital scanner.

123Scan Configuration

Page 152

12 - 2 Symbol DS6608 Product Reference Guide

Page 153

Chapter 13 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. The digital scanner is shipped with the settings shown in the Symbology Default Table on page 13-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down. NOTE

Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.

If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan *Set All Defaults on page 4-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*Enable UPC-A

Feature/Option

Page 154

13 - 2 Symbol DS6608 Product Reference Guide

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 13-14. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Symbology Parameter Defaults Table 13-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 13-7. NOTE

See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.

Table 13-1 Symbology Default Table

Parameter

Parameter Number

Default

Page Number

UPC/EAN UPC-A

01h

Enable

13-7

UPC-E

02h

Enable

13-7

UPC-E1

0Ch

Disable

13-8

EAN-8/JAN 8

04h

Enable

13-8

EAN-13/JAN 13

03h

Enable

13-9

Bookland EAN

53h

Disable

13-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

13-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

F1h 43h F1h 44h

UPC/EAN/JAN Supplemental Redundancy

50h

10

13-13

Transmit UPC-A Check Digit

28h

Enable

13-14

Transmit UPC-E Check Digit

29h

Enable

13-14

13-13

Page 155

Symbologies 13 - 3

Table 13-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Transmit UPC-E1 Check Digit

2Ah

Enable

13-15

UPC-A Preamble

22h

System Character

13-16

UPC-E Preamble

23h

System Character

13-17

UPC-E1 Preamble

24h

System Character

13-18

Convert UPC-E to A

25h

Disable

13-19

Convert UPC-E1 to A

26h

Disable

13-19

EAN-8/JAN-8 Extend

27h

Disable

13-20

Bookland ISBN Format

F1h 40h

ISBN-10

13-21

UCC Coupon Extended Code

55h

Disable

13-22

Code 128

08h

Enable

13-22

UCC/EAN-128

0Eh

Enable

13-23

ISBT 128

54h

Enable

13-23

Code 39

00h

Enable

13-24

Trioptic Code 39

0Dh

Disable

13-24

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

13-25

Code 32 Prefix

E7h

Disable

13-25

Set Length(s) for Code 39

12h 13h

2 to 55

13-26

Code 39 Check Digit Verification

30h

Disable

13-28

Transmit Code 39 Check Digit

2Bh

Disable

13-28

Code 39 Full ASCII Conversion

11h

Disable

13-29

Buffer Code 39

71h

Disable

13-30

Code 93

09h

Disable

13-32

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

13-33

Code 11

0Ah

Disable

13-35

Set Lengths for Code 11

1Ch 1Dh

4 to 55

13-35

Code 11 Check Digit Verification

34h

Disable

13-37

Code 128

Code 39

Code 93

Code 11

Page 156

13 - 4 Symbol DS6608 Product Reference Guide

Table 13-1 Symbology Default Table (Continued)

Parameter Transmit Code 11 Check Digit(s)

Parameter Number

Default

Page Number

2Fh

Disable

13-38

Interleaved 2 of 5 (ITF)

06h

Enable

13-38

Set Lengths for I 2 of 5

16h 17h

14

13-39

I 2 of 5 Check Digit Verification

31h

Disable

13-41

Transmit I 2 of 5 Check Digit

2Ch

Disable

13-41

Convert I 2 of 5 to EAN 13

52h

Disable

13-42

Discrete 2 of 5

05h

Disable

13-43

Set Length(s) for D 2 of 5

14h 15h

12

13-43

Codabar

07h

Disable

13-45

Set Lengths for Codabar

18h 19h

5 to 55

13-45

CLSI Editing

36h

Disable

13-47

NOTIS Editing

37h

Disable

13-47

MSI

0Bh

Disable

13-48

Set Length(s) for MSI

1Eh 1Fh

4 to 55

13-48

MSI Check Digits

32h

One

13-50

Transmit MSI Check Digit

2Eh

Disable

13-50

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

13-51

Inverse 1D

F1h 4Ah

Regular

13-52

US Postnet

59h

Enable

13-53

US Planet

5Ah

Enable

13-53

Transmit US Postal Check Digit

5Fh

Enable

13-54

UK Postal

5Bh

Enable

13-54

Transmit UK Postal Check Digit

60h

Enable

13-55

Japan Postal

F0h 22h

Enable

13-55

Australian Postal

F0h 23h

Enable

13-56

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Postal Codes

Page 157

Symbologies 13 - 5

Table 13-1 Symbology Default Table (Continued)

Parameter

Parameter Number

Default

Page Number

Dutch Postal

F0h 46h

Enable

13-56

4State Postal

F1h 50h

Disable

13-57

GS1 DataBar-14

F0h 52h

Enable

13-58

GS1 DataBar Limited

F0h 53h

Enable

13-58

GS1 DataBar Expanded

F0h 54h

Enable

13-59

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

13-59

Composite CC-C

F0h 55h

Disable

13-60

Composite CC-A/B

F0h 56h

Disable

13-60

Composite TLC-39

F0h 73h

Disable

13-61

UPC Composite Mode

F0h 58h

Always Linked

13-62

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

13-63

UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes

F0h ABh

Disable

13-63

PDF417

0Fh

Enable

13-64

MicroPDF417

E3h

Disable

13-64

Code 128 Emulation

7Bh

Disable

13-65

Data Matrix

F0h 24h

Enable

13-66

DataMatrix Inverse

F1h 4Ch

Regular

13-67

Maxicode

F0h 26h

Enable

13-68

QR Code

F0h 25h

Enable

13-68

MicroQR

F1h 3Dh

Enable

13-69

QR Inverse

F1h 4Bh

Regular

13-69

Aztec

F1h 3Eh

Enable

13-70

Aztec Inverse

F1h 4Dh

Regular

13-70

Redundancy Level

4Eh

1

13-71

Security Level

4Dh

1

13-73

GS1 DataBar

Composite

2D Symbologies

Symbology-Specific Security Levels

Page 158

13 - 6 Symbol DS6608 Product Reference Guide

Table 13-1 Symbology Default Table (Continued)

Parameter Intercharacter Gap Size Report Version

Parameter Number F0h 7Dh

Default Normal

Page Number 13-74 13-74

Macro PDF Flush Macro PDF Buffer

13-75

Abort Macro PDF Entry

13-75

Page 159

Symbologies 13 - 7

UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below.

*Enable UPC-A (01h)

Disable UPC-A (00h)

Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.

*Enable UPC-E (01h)

Disable UPC-E (00h)

Page 160

13 - 8 Symbol DS6608 Product Reference Guide

Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE

UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1 (01h)

*Disable UPC-E1 (00h)

Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.

*Enable EAN-8/JAN-8 (01h)

Disable EAN-8/JAN-8 (00h)