The text of a manual · part 15 of 18
VRC 8900 Radio Terminal Product Reference Guide: Chapter 8 Maintenance and Troubleshooting
Pages 97 to 100 of 112, from VRC 8900 Radio Terminal Product Reference Guide
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol VRC-8946
Page 97
Chapter 8 Maintenance and Troubleshooting Maintaining the Terminal The terminal is factory-sealed and contains no user-serviceable parts. Only qualified Symbol Service Centers should service the terminal. Refer to Symbol Support Center on page ix. Protective caps are attached to the ports on the back of the terminal. Place them over unused ports for protection.
Cleaning the Terminal The terminal requires a minimal amount of maintenance. To prolong its life and avoid problems, keep the terminal clean. Use a clean, soft cloth dampened with a mild cleanser such as soap and water to clean the terminal. Do NOT use cleaners containing a high percentage of alcohol, such as Isopropyl Alcohol. Do NOT use abrasive paper/cloth or abrasive/corrosive cleaners.
Storage Store the terminal in a cool, dry place away from dust. The terminal’s internal battery completely discharges in 72 hours. All non-volatile data is lost when the internal battery is fully discharged.
8-1
Page 98
VRC 8900 Radio Terminal Product Reference Guide
Troubleshooting Table 8-1 covers some common terminal problems and corrective actions to take. Table 8-1. Terminal Problems Symptom
Possible Cause
Terminal does not power on or shuts off suddenly.
Power switch on back of terminal is in the Off position.
Action Turn the power switch on.
Power cable not connected or Connect power cable to power cable unplugged. portion underside of terminal. Turn the power switch on, then press the Suspend Button to boot up the terminal. If the terminal is powered by a Replace or charge the vehicle vehicle battery, the vehicle battery. battery is depleted. Cannot see characters on display.
Terminal not powered on (Power LED is off).
Turn the power switch on. Press the Suspend Button.
Screen is too bright/dark.
Adjust the brightness; see Adjusting the Brightness on page 4-16.
Display not adjusted properly. Select Display in the Control Panel settings and adjust the display. The terminal is in Suspend mode (indicated by a yellow Power LED).
Press the Suspend Button to turn on the terminal.
Touchscreen not working.
Display not properly calibrated.
Recalibrate the screen through the Control Panel Calibration utility. If problem continues, contact Symbol Support Center. See Symbol Support Center on page ix.
Optional scanner does not operate.
Scanner is not properly connected to the terminal.
Connect the scanner to the COM1 port and power up the terminal. If the problem continues, refer to the scanner Quick Reference Guide.
8-2
Page 99
Maintenance and Troubleshooting
Table 8-1. Terminal Problems (Continued) Symptom
Possible Cause
No sound is heard when you Volume is turned down. tap the touchscreen or press a key. Application currently running disabled the sound. Faulty speaker.
Action Adjust the volume in the Control Panel. Configure the application to enable the sound. Contact Symbol Support Center. See Symbol Support Center on page ix.
Missing pixels on the display. Faulty LCD.
Contact Symbol Support Center. See Symbol Support Center on page ix.
COM1 or COM2 port is not working.
Another application is using the port.
Stop the application using the port and retry. Use COM1 port for scanning and COM2 port for ActiveSync.
No response when ActiveSync is initiated.
ActiveSync cable not connect- Connect the ActiveSync cable. ed properly.
No keys are working on the optional keyboard.
Application does not respond.
ActiveSync is not configured properly in the Control Panel.
Configure ActiveSync in the Control Panel. See Performing an ActiveSync on page 7-2.
The keyboard is not properly connected to the terminal.
Check the cable connections between the keyboard and the terminal.
The application does not require keyboard input.
Configure the application to use the keyboard.
Terminal is not responding.
Cold boot the terminal.
Terminal is not communicating with the AP (Communication LED is solid red).
Bring the terminal closer to the AP. If problem continues, contact Symbol Support Center. See Symbol Support Center on page ix.
8-3
Page 100
VRC 8900 Radio Terminal Product Reference Guide
8-4