Page 83

Chapter 6 Configuring the Terminal Introduction This chapter describes the terminal’s Flash partitions and how they are used to specify and load files into the Flash memory of the terminal using ActiveSync.

Flash Partitions In addition to the RAM-based storage standard on Windows CE terminals, the VRC 8900 is equipped with a non-volatile Flash-based storage area which can store data (partitions) that cannot be corrupted by a cold boot. This Flash area is divided into two categories: Flash File System (FFS) Partitions and Non-FFS Partitions.

FFS Partitions The terminal includes one FFS partition. This partition appears to the terminal as a hard drive that the OS file system can write files to and read files from. Data is retained even if power is removed. The FFS Partition is used to store application programs needed to operate the terminal. This partition is also available for user data files generated by your custom programs.

6-1

Page 84

VRC 8900 Radio Terminal Product Reference Guide

The partition contains one volume with the folder CopyToRAM, which contains four subfolders: CopyToRAM

User application files which need to be loaded into RAM prior to execution

\Root applications or files placed in this folder are copied to the root directory while maintaining their directory structure

\Startup applications placed in this folder are permanently stored in Flash but copied to DRAM and executed on start up

\System applications or data placed in this folder are permanently stored in Flash but copied to the \Windows folder in DRAM upon cold/warm boot

\User

User application files

Non-FFS Partitions Non-FFS Partitions include software and data pre-loaded on your terminal. Unlike the FFS Partition, these partitions are not visible when the operating system is running. They also contain system information. Non-FFS Partitions include the following: •

Windows CE: the complete Windows CE operating system is stored on Flash devices. If necessary, the entire OS image may be downloaded to the terminal using files provided by Symbol. Any upgrades must be obtained from Symbol. This partition is mandatory for the VRC 8900.

•

Boot Loader: initializes the CE operating system prior to starting CE and provides a simple method of updating the Flash contents via a serial port.

Downloading the Operating System To download the operating system via the serial port, the following equipment is required: •

PC

•

ActiveSync cable

•

Compressed Windows CE image (*.BIN file)

•

OSUPDATE.EXE

1. Connect the ActiveSync cable to the COM1 port on the terminal and an available COM port on the PC.

6-2

Page 85

Configuring the Terminal

2. Power on the unit while holding down the P1 and P3 keys. The following menu appears: VRC8900 BootLoader Boot Ver X.X.XXX

Boot Menu: 1 - Hard Boot 2 - Use Default Registry 3 - Service Menu 4 - Power Down

Figure 6-1. Boot Menu 3. Press the Brightness “-” (minus) button on the switch panel to highlight 3 - Service Menu. Brightness “-” Button

Figure 6-2. Brightness Button Press the P2 button. The following menu appears.

6-3

Page 86

VRC 8900 Radio Terminal Product Reference Guide

VRC8900 BootLoader Boot Ver X.X.XXX

Service Menu: 1 - Download OS 2 - Production Tests 3 - Final Build Tests 4 - Display Test Info 5 - Kill File System

Figure 6-3. Service Menu 4. Press the P2 button to select 1 - Download OS. The following screen appears.

6-4

Page 87

Configuring the Terminal

VRC8900 BootLoader Boot Ver X.X.XXX

Download from: 1 - PCMCIA 2 - Serial

Figure 6-4. Download Menu 5. Press the Brightness “-” (minus) button on the switch panel to highlight 2 - Serial. Press the P2 button to select this. 6. Before selecting an option, set up the desktop PC as follows: a. Start the program OSUPDATE.EXE. The following screen appears:

Figure 6-5. OSUpdate Screen

6-5

Page 88

VRC 8900 Radio Terminal Product Reference Guide b. Leave the Baud Rate set to 115200. c. Leave the Data Bits, Parity, Stop Bits, and Flow Control set as 8, None, 1, and None, respectively. d. To specify the operating system for upgrade, either type in the full location of the Windows CE image in the text box or search for it by clicking the “...” button. e. Click the Update OS button. The following screen appears:

Figure 6-6. Device Connection Screen f. Select option 3 (115200) on the VRC 8900 to initiate the download. A screen similar to the following appears on the PC:

Figure 6-7. File Copy Screen It takes approximately 20 minutes to download a 15MB file. 7. When the download is complete a message appears on the VRC 8900 asking if the uploaded version should replace the existing version. Use the Brightness “+” and Brightness “-” buttons on the panel to toggle between Yes and No. If you select Brightness “+” (Yes), the VRC 8900 checks the CRC of the downloaded operating system before transferring it from SDRAM to Flash memory. DO NOT switch off the terminal before this transfer is complete or the Flash

6-6

Page 89

Configuring the Terminal memory will only contain part of the operating system and you must download again. 8. When complete, you are prompted to restart the terminal. Restart the VRC 8900. The new operating system takes effect. After downloading a new operating system, it is recommended that you use the default registry. See DRAM File System on page 4-19 for instructions on using the default registry.

Downloading Applications To download an application via the serial port, the following equipment is required: •

Desktop PC

•

ActiveSync cable

•

Application compiled for the VRC 8900, or installation file for PC

•

Microsoft ActiveSync installed and configured on the desktop PC.

6-7

Page 90

VRC 8900 Radio Terminal Product Reference Guide

To download an application compiled for the VRC 8900: 1. Connect the ActiveSync cable to the COM2 port of the terminal and an available COM port on the desktop PC. The terminal automatically connects to the desktop PC. After synchronization between the terminal and the PC is established, the following screen displays on the PC:

Figure 6-8. ActiveSync Connection Screen 2. Click the Explore button to display the desktop of the terminal in another screen as follows:

Figure 6-9. Mobile Device Screen

6-8

Page 91

Configuring the Terminal

Double-click My Computer to view RAM and Flash memory on the terminal. Transfer files by ’dragging and dropping’ or ’copying and pasting’ from the PC to the specified location on the terminal. To download an installation file for the desktop PC, which, when unpacked has been compiled for VRC 8900, the file must first be executed so that it unpacks itself on the desktop PC: a. Select Tools, then Add/Remove Programs. The following screen appears:

Figure 6-10. Add/Remove Programs Screen b. To install the application on the terminal, check the box next to the application(s) to be installed. If the Install program into the default installation folder is checked, the application files are transferred to the Windows directory on the terminal. If this is unchecked, you may select the destination of the application in the screen that appears:

Figure 6-11. Select Destination Media Screen

6-9

Page 92

VRC 8900 Radio Terminal Product Reference Guide

Refer to DRAM File System on page 4-19 to increase memory if the program memory availability is lower than required. 3. Continue with the on-screen prompts on the PC and the terminal to complete the application installation. Note: If the application, or part of it, is installed in DRAM, it will be lost if the back-up battery is allowed to discharge or a cold boot is performed.

6-10