The text of a manual · part 3 of 4

VRC 6940 Installation Guide, pages 9 to 11

Pages 9 to 11 of 19: Providing Power: Vehicle Installations; Providing Power: Wall or Workbench Installations

The original document is the PDF (535 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol VRC-6940

Page 9

Providing Power: Vehicle Installations VRC 6940 terminals can be powered by: !

12V or 24V gas-powered vehicles

!

battery-powered vehicles, up to 60 volts

To provide power to a vehicle-installed VRC 6940: 1. Locate your vehicle’s power source. Always connect a VRC 6940 terminal to a continuous or unswitched power source. 2. Prepare the External DC power cable. One end of the power cable fits into the terminal’s DC Power connector. The other end has no connector (see Figure 6).

Plug in to the DC Power connector on the terminal

Cable End to be prepared

Figure 6. Preparing the External DC Power Cable To prepare the end of the External DC power cable: a.

In-line fuse holder: if no fused output is available, add a fuse-holder and 5 Amp fuse to the External DC power cable. Follow these steps and refer to Figure 7: i. Strip back six inches of the cable jacket. ii. Cut about 5” from the red power wire and strip 3/8” insulation from the wire. iii. Strip 3/8” insulation from the fuseholder wire. iv. Twist the stripped wire ends together and splice them using a twist-on nylon wire connector.

Installation Note: Power Sources The ideal location for connecting a VRC 6940 External DC power cable would be a fused power source on the vehicle’s power distribution panel. If no fused power source is available, connect the terminal directly to a vehicle battery. In this case, Symbol recommends you use an in-line fuse holder and 5A slow-blow fuse. The fuse protects your vehicle from an electrical short on the power cable.

9

Page 10

VRC 6940 Installation Guide

Red power wire i.

ii.

In-line fuse holder with 5A slow-blow fuse

Twist-on nylon wire connector iii.

iv.

v. Wrapped wires and fuse holder

Figure 7. Adding an In-line Fuse Holder v. Make sure the fuse holder contains a 5 Amp slow-blow fuse. Wrap the wires neatly, as necessary. b. Route the External DC power cable from the terminal location to the connection point for your vehicle’s power source. See the Installation Note below. ! Installation Note: Cable Routing Caution ! The means of routing and securing the External DC power cable from the terminal to the vehicle power source is extremely important. Hazards associated with improper wiring can be severe. To avoid unintentional contact between the wire and any sharp edges, provide the cable with proper bushings and clamping where it passes through openings. If the wire is subjected to sharp surfaces and excess engine vibration, wiring harness insulation can wear away, causing a short between the bare wire and chassis. This can start a fire.

10

Page 11

c. Prepare the cable termination: Strip Installation Note: Cable Termination 3/8” of insulation from the two wire How the cable terminates depends on ends and terminate them with a your vehicle. If your vehicle has a power connector that matches your vehicle’s output connector, then attach a mating requirements. See the Installation connector to the end of the power cable. Note, right, for more information. You may be able to connect to a fuse d. Connect the red wire to the vehicle panel with a commercially available power source. Connect the black wire connector. If your vehicle has no power to a vehicle ground wire or chassis output connector, attach a ring terminal (for a battery post) or blade terminal ground. connector (for a fuse panel). e. Connect the External DC power cable Consult your vehicle Owner’s Manual to your vehicle power source. for information on how to access your 3. Insert the terminal end of the External vehicle’s power supply. DC power cable into the terminal’s Power Connector. Align the red dot on the end of the power cable with the red dot on the Power Connector.

WARNING A Lead Acid battery can leak Hydrogen gas. A spark anywhere near the battery can cause it to explode. Always make your final connection to power as far away from the battery as possible, i.e., connect the power cable to the battery first, then connect it to the terminal.

Providing Power: Wall or Workbench Installations For wall or workbench-mounted terminals, or for operating a terminal while away from a vehicle, you can power an VRC 6940 from an AC universal power supply. You need the AC universal power supply, an AC line cable, and a DC power cable as listed on page 5. To provide power from an AC source: 1. Insert the AC line cable into the AC connector on the AC universal power supply. 2. Plug the other end of the AC line cable into an AC wall outlet. 3. Insert the DC power cable into the DC connector on the AC universal power supply. 4. Plug the other end of the cable into the terminal’s Power Connector.

11