The text of a manual · part 3 of 4
Synapse "Smart Cable" for PC Wedge Interface Guide, pages 17 to 24
Pages 17 to 24 of 32
The original document is the PDF (214 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol STI80-0100 and Symbol STI80-0200
Page 17
PC Wedge
Advanced Features Select Parameter Set This option allows you to store different parameter settings for each place the scanner is used, as well as to select a parameter set once it is programmed. Programming Parameter Sets To program the parameter set where the scanner is connected to a host, scan a Select Parameter Set bar code, then scan the parameter options in this guide needed for this set. Note: Because Parameter Set 1 is the default, you don’t need to scan this bar code - the first group of parameters you select will automatically be designated Parameter Set 1. Enabling a Parameter Set To enable the set you’ll be using after it’s programmed, scan that Select Parameter Set bar code.
15
Page 18
SynapseTM “Smart Cable” Guide
Select Parameter Set 1 (Default)
Select Parameter Set 2
16
Page 19
PC Wedge
Set Synapse Defaults (Advanced) Scan the following bar code to set defaults for the current parameter set.
Set Synapse PC Wedge Defaults: Current Parameter Set
Scan the bar code below to set defaults for all Synapse cables.
Set Synapse Defaults: All Cables And Parameter Sets
17
Page 20
SynapseTM “Smart Cable” Guide
Translation to Control Sequence The following barcodes allow a special treatment for the following ASCII characters; TAB (09), ESC (27), BS (08) and CR (13). By default these characters are translated by Synapse to the following control sequence, respectively; CTRL-I, CTRL-[, CTRL-H, CTRL-M.
Send Control Key Sequence Default
To disable this translation, scan the barcode below. The characters will be sent as the following keystrokes; TAB, ESC, BACKSPACE, Enter. This option is particularly useful when sending scanner data into Windows applications that interpret CTRL keys in a different way.
Send Control Key Codes
18
Page 21
PC Wedge
Keyboard Maps The keyboard maps on the following pages are provided for prefix/suffix keystroke parameters, and are used only with scanners that support data formatting. To program the prefix/suffix values, refer to your scanner’s Programming Guide. Note: If you are programming an LS 1000 scanner, please refer to the LS 1000 Product Reference Guide for keyboard values.
19
Page 22
5009 5010
5007 5008
5005 5006
5003 5004
5001 5002 7 009
7 014
IBM PC/XT
7004
7012
7011
7 013
7008
7002
7006
7003
Page 23
5 009 5010
5 007 5 008
5 005 5 006
IBM PC/AT
7 011
7 004
7012 7 013
5 003 5 004 7009
7 008 7014
5 001 5 002
7002
7003
Page 24
7009
7014
5001
5002
5003
5004
5005
5006
5008
5009
IBM PS/2
5007
5010
7013
7008
5011
5012
7012
7004
7011
7002
7005
7003