SPT 1700 Series Quick Reference, pages 11 to 20

Pages 11 to 20 of 28

The original document is the PDF (642 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol SPT-1700 and Symbol SPT-1733 1734

Page 11

Q u i c k

R e f e r e n c e numbers. See the SPT 1700 Product Reference Guide, p/n 7037544-xx for more information.

Using the Onscreen Keyboard You can activate the on-screen keyboard any time you need to enter text or numbers on your SPT 1700. Note that you cannot enter Graffiti characters while using the on-screen keyboard. To use the on-screen keyboard: 1. Open any SPT 1700 application. 2. Tap any record name, or tap the New button with the tip of the stylus. 3. Tap the left target to open the Alpha keyboard, or tap the right target to open the Numeric keyboard.

Tap here for numbers keyboard

Tap here for letters keyboard

9

Page 12

S P T

1 7 0 0

S e r i e s

Icon Descriptions Applications Icon

Exits the current application and lists available applications for selection.

Calculator Icon

Displays the calculator application.

Menu Icon

Tap from within an application to display the options menu for the application.

Find Icon

Tap from within an application to enter search criteria to find an entry.

Resetting Your SPT 1700 Terminal If your SPT 1700 stops responding to input, you may need to perform a reset.

Performing a Soft Reset A soft reset restarts the terminal and saves all records and entries stored in your SPT 1700 terminal. After a soft reset, the Palm Computing Platform Logo screen appears followed by the General Preferences screen. To perform a soft reset, remove the battery cover and gently press the reset button, which is located under the battery cover.

10

Reset button

Page 13

Q u i c k

R e f e r e n c e

Performing a Hard Reset A hard reset also restarts your terminal, but erases all records and entries stored in your SPT 1700 terminal. Therefore, never perform a hard reset unless a soft reset does not solve your problem. Note:

You can restore any data previously synchronized with your computer during the next HotSync operation.

To perform a hard reset: 1. Remove the battery cover. 2. Hold down the power button on the front of the SPT 1700 terminal, and gently press the reset button on the back of the terminal. 3. Release the reset button, then the power button. 4. When a message appears on the SPT 1700 terminal screen warning that you are about to erase all the data stored on your SPT 1700 terminal, do one of the following: a. Press the upper half of the scroll button on the front of the SPT 1700 terminal to complete the hard reset and display the Digitizer screen. b. Press any other button to perform a soft reset. Note:

With a hard reset, the current date and time are retained. Formats Preferences and other settings are restored to their factory default settings.

11

Page 14

S P T

1 7 0 0

S e r i e s

Attaching the Handstrap The SPT 1700 has an optional handstrap which increases comfort when holding the terminal for extended periods of time. To attach the handstrap to the back of the terminal:

Thread round metal piece through this connector

1. Thread the round metal piece through the metal handstrap connection.

Slide flat metal piece up and into this connector

2. Slide the flat metal piece into the handstrap connection on the bottom of the terminal. 3. Adjust the velcro® strap to fit your hand.

Scanning 1-D Bar Codes with the SPT 1700 The SPT 1700 has an integrated laser bar code scanner which, if your unit has been configured to use scanning input, allows you to collect data by scanning bar codes. To scan bar codes with the SPT 1700: 1. Start your scanning application. 2. Aim the scanner at the bar code. 3. Press either the right, left or center scan trigger. Make sure the red scan beam covers the entire bar code. The green scan LED lights and a beep sounds to indicate a successful decode.

12

Page 15

Q u i c k

R e f e r e n c e

Scanning PDF417 (2-D) Bar Codes To scan a PDF417 bar code (with a 2-D configured terminal): 1. Aim the scanner at the PDF bar code and press the trigger. 2. Hold the trigger down and keep the scan line parallel to the rows of the symbol. 3. Manually raster the scan line by slowly moving the scanner up and down so it scans the entire bar code at a rate of one inch per second. A clicking noise lets you know the 2-D bar code is being decoded. If there is no clicking noise when you’re scanning the bar code, it’s not being scanned properly. When decoding a very long 2-D bar code, you may notice a slight delay between the time when the terminal completes the decode and the time when the data is displayed on the screen. The first beep you hear indicates a successful decode. The second beep you hear indicates the data has been received by the host. Do not attempt to decode another bar code until you hear the second beep and see the green LED indicating successful decode. To improve PDF decoding: • • • • •

Check that PDF417 scanning is enabled. Make sure the scan line extends at least 1/2” past the left and right edges of the bar code. Hold the scanner closer for denser symbols, farther away for larger symbols. Make sure you scan the top and bottom rows of the symbol. Be patient - it may take a few swipes to decode the symbol.

13

Page 16

S P T

1 7 0 0

S e r i e s

The bar code has been completely decoded when you hear a tone, followed by a short, high tone beep. The green LED stays lit for two seconds or until the next trigger pull. 1/2”

1/2”

Scan Line

Initiate A Network Connection Before using the terminal, set up the Spectrum24, CDPD (Cellular Digital Packet Data) or GSM (Global System for Mobile Communication) network connection. Refer to the SPT 1700 Series Product Reference Guide, p/n 70-37544-xx for setup instructions. A small cursor blinks at the top right-hand corner of the screen when the terminal activates a radio connection (Spectrum24, CDPD or GSM). If you are not connected to the radio, the cursor does not appear.

Maintaining the SPT 1700 For trouble-free service, observe the following tips when using your SPT 1700: •

•

• •

Do not scratch the screen. Use the supplied stylus or plastictipped pens intended for use with a touch-sensitive screen. Never use a pen or pencil or other sharp object on the screen. Although your SPT 1700 is water and dust resistant, do not expose it to rain or moisture for an extended period. Treat your SPT 1700 as you would a pocket calculator or other small electronic instrument. The touch-sensitive screen of your SPT 1700 contains glass. Do not drop your SPT 1700 or subject it to strong impact. Protect your SPT 1700 from temperature extremes. Do not leave it on the dashboard of a car on a hot day, and keep it away from heaters and other heat sources. 14

Page 17

Q u i c k

• •

R e f e r e n c e

Do not store or use your SPT 1700 in any location that is extremely dusty, damp or wet. If the surface of the SPT 1700 screen becomes soiled, clean it with a soft lens cloth moistened with a diluted window-cleaning solution.

Troubleshooting SPT 1700 terminal does not turn on: • • •

Adjust the contrast control. Make sure the battery is fully charged and installed properly. Replace the battery. If your SPT 1700 terminal still does not operate, try a soft reset; see Resetting Your SPT 1700.

Low battery warning after replacing the battery: •

The battery warning message may appear immediately after replacing the battery. In addition, if you check the battery gauge in the Applications Launcher immediately after replacing the battery, the gauge may start at “empty” and slowly rise to “full.” This is normal. It takes a minute for the battery gauge to accurately show the condition of the battery.

No sound: •

Check the Sound options in the General Preferences screen. If the option is set to off, there will be no sound. See the SPT 1700 Product Reference Guide for more information.

SPT 1700 terminal turns itself off: •

Your SPT 1700 terminal is designed to turn itself off after a period of inactivity. This period can be set at thirty seconds, one minute, two minutes or three minutes. Check the “Auto-off after” setting in the General Preferences screen, and change the setting if you need a longer delay before the automatic shutoff feature activates. See the SPT 1700 Product Reference Guide for more information. The terminal also turns itself off when the battery power is extremely low. 15

Page 18

S P T

1 7 0 0

S e r i e s

SPT 1700 terminal doesn’t recognize my handwriting: •

• •

•

For your SPT 1700 to recognize handwriting input with the stylus, you need to use the Graffiti® character strokes. See the SPT 1700 Product Reference Guide for information about how to write Graffiti character strokes. Make the Graffiti character strokes in the Graffiti writing area, not on the display part of the screen. Make sure you are writing the strokes for letters in the lefthand side, and the strokes for numbers in the right-hand side of the Graffiti writing area. Make sure that Graffiti is not shifted into extended or punctuation modes. See the SPT 1700 Product Reference Guide for information about shifting into and out of punctuation modes.

Tapping the screen buttons or icons does not activate the corresponding feature: •

Recalibrate the digitizer. Choose Digitizer from the Preferences application pick list and follow the directions on the screen.

When I tap the • icon, nothing happens:

Not all applications or screens have menus. Try changing to a different application.

Beamed data does not transmit: •

Confirm that the SPT 1700 terminals are 5” apart, the receiver has its IrDA capability enabled, and that the path between the two devices is clear of obstacles. Note:

You cannot overwrite a .prc file via IrDA if it is locked.

When receiving beamed data an out of memory message appears: •

Your SPT 1700 terminal requires at least twice the amount of memory available as the data you are receiving. For example,

16

Page 19

Q u i c k

R e f e r e n c e if you are receiving a 30K application, you must have at least 60K free. Your SPT 1700 unit does not accept scan input: •

Verify that the unit is loaded with a scanning application. See your System Administrator. • Check to be sure the bar code symbol is not defaced. • Be sure you are within proper scanning range. • Be sure the unit is programmed to accept the type of bar code you are scanning. • If you are expecting a beep on a good decode and don’t hear one, check that the application is set to generate a beep on good decode. • If the scanner stops emitting a laser beam when you press the trigger, check your battery level. When the battery is low, the scanner shuts off before the terminal notifies you of the low battery condition. Note: If, after performing these checks, the scanner is still not reading symbols, contact your distributor or Symbol Technologies.

Ergonomic Recommendations Caution: In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are meeting with your company’s safety programs to prevent employee injury. • Reduce or eliminate repetitive motion • Maintain a natural position • Reduce or eliminate excessive force • Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures.

17

Page 20

S P T

1 7 0 0

S e r i e s

Regulatory Information Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC Part 15. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Important Note: To comply with FCC and Industry Canada RF exposure requirements, this hand-held device is approved for operation in a user's hand when there is 20 cm or more between the antenna and the user's body.

Radio Frequency Interference Requirements - Canada This Class B digital apparatus meets the requirements of the Canadian InterferenceCausing Equipment Regulations. Cet appareil numérique de la Classe B respecte toutes les exigences du Reglement sur le Materiél Brouilleur du Canada.

CE Marking and European Union Compliance Products intended for sale within the European Union are marked with the CE Mark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included: