Page 34

SPT 1700 Series Product Reference Guide

Note: Your SPT 1700 terminal requires a dedicated port. It cannot share a port with an internal modem or other device. If you are unsure about the location of the serial port on your computer, refer to the user’s manual supplied with the computer. Refer to Chapter 9, Applications: HotSync® for instructions on configuring the cradle and terminal for modem synchronization.

CRD1700-4000E Ethernet Cradle Before setting up the cradle, make sure that Symbol Palm Terminal Desktop Software (p/n SW-35138-xx) is installed and running on the host computer, as well as properly configured Network HotSync software on the SPT 1700 terminal. Refer to the section Symbol Palm Terminal Desktop Software on page 1-23 for instructions on installing this software. Specific software setup necessary to use the CRD1700-4000E is discussed in Chapter 9, Applications: HotSync®. A DHCP server must be configured and operational on the subnet to which the cradle will be attached. To connect the cradle: 1. Connect the power supply cable round plug to the power connector on the back of the cradle. 2. Connect the power supply AC plug to a standard electrical outlet. Note: International customers must use a separate AC power cable appropriate for their respective country.

DC Power Connector

The cradle’s LEDs blink, then remain off until a terminal is inserted into one or more of the slots.

1-10

Page 35

Getting Started with the SPT 1700

To set up for network communications: 1. Ensure there is a DHCP server accessible to the CRD1700-4000E on the subnet to which it will be attached. 2. Connect one end of a standard 10 Base-T network cable to the middle connector on the back of the CRD1700-4000E. Connect the other end of the cable to a hub which is connected to your subnet. 3. Power-up the unit; the CRD1700-4000E performs its power-up sequence, then attempts to collect all network parameters from the local DHCP server.

If configuration of the unit from the local DHCP server fails, all LEDs flash red. The unit becomes unresponsive until power is removed, the unit is connected to a network with a DHCP server, and power is restored. Note: Before communication between the SPT 1700 terminal and the host computer can take place, the Symbol Palm Terminal Desktop Software must be installed and running on the host computer.

VCD 1700 Series Vehicle Cradle The SPT 1700 provides a serial port at the bottom of the terminal. When you insert a terminal into a VCD 1700 cradle, it connects to the cradle’s serial port. The terminal can then use the cradle’s serial port to communicate with an external device. To connect the cradle: 1. Plug a 9-pin serial cable into the serial port located next to the power port at the bottom of the cradle. Note that some devices may require the serial cable to be a null modem cable.

1-11

Page 36

SPT 1700 Series Product Reference Guide

Power Input Cable

To Vehicle Power Source

Serial Cable

To External Device

Note: The external device must use an RS-232 serial connection limited to TXD, RXD, RTS and CTS data lines. It must also have its own power supply, as the cradle’s serial port does not provide power. 2. Connect the other end of the cable to the serial port of the external device (e.g., a host computer, printer, or modem). To begin communication: 1. Insert the terminal into the cradle. 2. Connect the Power Input cable to your vehicle power source. Then plug the cable into the Power Port on the terminal. 3. To initiate communication, make appropriate selections on the terminal, as determined by the application you are using. Note: Removing a terminal during data communication will disrupt communication between the terminal and the attached device.

1-12

Page 37

Getting Started with the SPT 1700

Installing the Battery To install the battery in your SPT 1700: 1. Open the latches on the battery cover and lift it away from the SPT 1700.

Latch Latch

2. Insert the lithium-ion battery in the battery compartment, making sure it snaps into place.

3. Replace the battery cover and re-secure the latches. Note: Be careful to position the battery latches completely open while securing the battery cover on the terminal.

1-13

Page 38

SPT 1700 Series Product Reference Guide

Charging the Battery Before using your SPT 1700 for the first time, charge the lithium-ion battery. The terminal’s battery can be charged using the Cradle, the Synchronization/Charging Cable, or the Universal Battery Charger (UBC). For instructions on using the UBC to charge your batteries, refer to the Quick Reference Guide which came with your UBC. Follow these same procedures to recharge the battery when the terminal’s battery level is low.

Using the Cradle to Charge the Battery To charge the terminal’s battery using the CRD 1700 cradle: 1. Make sure the battery is installed in the terminal. Refer to Installing the Battery on page 1-13 for instructions. 2. Make sure the cradle is plugged into a wall outlet. 3. Insert the SPT 1700 terminal in the cradle as shown:

Battery Charging LED

On the CRD1700-1000S, the battery charging LED turns red to indicate that the battery is charging, then turns green after approximately two hours to indicate that the terminal’s battery is fully charged.

Spare Battery Charging The CRD1700-1000S single-slot cradle has a spare battery charging slot which charges the terminal’s spare battery. Insert the battery in the spare battery charging slot in the back of the cradle. The spare battery charging LED turns red to indicate the spare battery is

1-14

Page 39

Getting Started with the SPT 1700 charging, then turns green after approximately two hours to indicate the battery is fully charged.

Spare Battery Charging LED

Attaching the Handstrap The SPT 1700 has an optional handstrap which increases comfort when holding the terminal for extended periods of time. To attach the handstrap to the back of the terminal: 1. Thread the metal piece through the metal handstrap connection on the back of the terminal.

1-15

Page 40

SPT 1700 Series Product Reference Guide

2. Slide the flat metal piece into the handstrap connection on the bottom of the terminal.

Thread metal piece through this connector

Slide flat metal piece up and into this connector

3. Adjust the velcro® strap to fit your hand.

Starting the SPT 1700 After charging and installing the battery, start the terminal by pressing the red power button on the front of the unit. If the terminal does not power on, perform a hard reset. Note: When starting the terminal for the first time, or whenever the battery is completely drained, a hard reset is required. To hard-reset the terminal: 1. Remove the battery cover from the back of the terminal. 2. Hold down the power button on the front of the SPT 1700 terminal. 3. While holding down the power button, use the tip of the stylus to gently press the reset button on the back of the terminal. 4. Release the reset button. 5. Release the power button.

1-16

Page 41

Getting Started with the SPT 1700

6. When a message displays on the screen warning that you are about to erase all the data stored on your SPT 1700 terminal, do one of the following: a. Press the upper half of either of the scroll buttons on the front panel of the SPT 1700 terminal to complete the hard reset and display the Digitizer screen. b. Press any other button to perform a soft reset. Note: With a hard reset, the current date and time are retained. Formats Preferences and other settings are restored to their factory default settings. After initial start up, always start the terminal by pressing the red power button.

Calibrating the Screen The first time you start your SPT 1700 (or after a hard reset), the calibration screen displays. Follow the steps in this section to align the internal circuitry of your SPT 1700 with its touch-sensitive screen. Note: If your SPT 1700 unit came pre-loaded with a custom software application, you may not need to calibrate your screen, in which case you will not see the calibration screen. To calibrate your SPT 1700 for first time use: 1. Press the power button on the front panel of your SPT 1700 to display the calibration screen. (This screen also displays following a hard reset).

Power Button

2. Remove the stylus from its storage silo on the back of the SPT 1700. 1-17

Page 42

SPT 1700 Series Product Reference Guide

3. Tap the exact center of each target that displays on the screen with the tip of the stylus.

If you need to recalibrate the screen at any time, open the Prefs application, tap on the pulldown menu at the top right corner of the screen, and select the digitizer option.

Setting the Time The General Preferences screen is the first screen to display after you align the digitizer on your SPT 1700 terminal. Note: If the General Preferences screen is not on your SPT 1700 terminal screen, you may have pressed one of the application buttons on the front panel. Refer to General Preferences on page 14-10 for information on displaying the General Preferences screen.

1-18