Page 357

Getting Help With Your SPT 1700 Terminal

Troubleshooting If you encounter a problem with your SPT 1700 terminal, look in this section for the description that most closely matches the symptoms you observe and try the suggestions listed. Important: For troubleshooting tips not included in this handbook, refer to either the README.TXT file or the Help Notes file located in the Symbol Palm Terminal Desktop directory. These files are also on the installation CD-ROM.

Problem

Cause(s)

Solution

Installation Symbol Palm Terminal Desktop installation program incorrectly detects that a modem is attached to one of your serial ports.

Do not place your SPT 1700 terminal in the cradle while installing the software.

Serial Cradle LEDs do not light when Cradle is not receiving power. the cradle is plugged in.

Make sure the power supply is securely connected and receiving power.

LED does not light when the terminal is inserted.

Terminal is not seated firmly in the cradle.

Replace the terminal in the cradle.

Attempt by the cradle to HotSync the terminal failed.

Terminal was removed from the cradle while the LED was blinking green.

Replace the terminal in the cradle. This allows the cradle to attempt another HotSync.

Terminal’s battery is dead.

Recharge the battery.

Active Error dialog box on terminal.

Error dialog box must be cleared in the terminal. Tap the OK button on the terminal’s touchscreen.

20-9

Page 358

SPT 1700 Series Product Reference Guide

Problem

Cause(s)

Solution

Ethernet Cradle The unit locks up with all LEDs flashing red.

The unit could not configure Hook the unit up to an Ethernet itself, or it lost its lease on one of network with a correctly functioning its ID addresses. DHCP server and 6 available IP addresses.

General Issues SPT 1700 terminal does not turn on.

Adjust the contrast control. Recharge the battery. If your SPT Make sure the battery is charged 1700 terminal still does not operate, try a soft reset; refer to and installed properly. Resetting Your SPT 1700 Terminal on page 21-5 for details.

Low battery warning after recharging the batteries.

The battery warning message may display immediately after recharging the battery. In addition, if you check the battery gauge in the Applications Launcher immediately after recharging the battery, the gauge may start at “empty” and slowly rise to “full.”

This is normal. It takes a few minutes for the battery gauge to accurately show the condition of the battery.

No sound.

The System Sound option may not be set correctly in the General Preferences screen.

If the option is set to off, there will be no sound. Refer to General Preferences on page 14-10 for more information.

No sound upon good decode.

The System Sound option may not be set correctly in the General Preferences screen.

Verify that Beep on Good Decode is set (checked) in Hardware Setup in the Scan Demo Application. Refer to General Preferences on page 14-10 for more information.

SPT 1700 terminal turns itself off.

Your SPT 1700 terminal is designed to turn itself off after a period of inactivity. This period can be set at one minute, two minutes or three minutes.

Check the “Auto-off after” setting in the General Preferences screen, and change the setting if you need a longer delay before the automatic shutoff feature activates. Refer to General Preferences on page 1410 for more information.

20-10

Page 359

Getting Help With Your SPT 1700 Terminal

Problem SPT 1700 terminal doesn’t recognize my handwriting.

Cause(s)

Solution

You need to use the Graffiti Refer to Writing Graffiti with the character strokes for your SPT Stylus on page 3-6 for information 1700 terminal to recognize about how to write Graffiti handwriting input with the stylus. character strokes. You are making the Graffiti character strokes in the display part of the screen, not on the Graffiti writing area.

Make the Graffiti character strokes in the Graffiti writing area.

You are writing the strokes for letters in the left-hand side, and the strokes for numbers in the right-hand side of the Graffiti writing area.

Write the strokes on the proper side of the Graffiti writing area.

Tapping the screen The digitizer may need to be buttons or icons does recalibrated. not activate the corresponding feature.

Recalibrate the digitizer. Choose Digitizer from the Preferences application pick list and follow the directions on the screen.

When I tap the Not all applications or screens icon, nothing happens. have menus.

Try changing to a different application.

A message displays You may have too many unused stating that your SPT records. 1700 terminal memory is full.

Delete unused memos and records. If necessary, you can save these records on your computer using the Save Backup Copy option that displays in the Delete screens.

Beamed data does not The terminals may be too far transmit. apart.

Confirm that the SPT 1700 terminals are 1 ft. apart or less, and that the path between the two devices is clear of obstacles.

When receiving beamed data an out of memory message displays.

Your SPT 1700 terminal requires Verify the amount of free memory at least twice the amount of available. memory available as the data you are receiving. For example, if you are receiving a 30K application, you must have at least 60K free.

20-11

Page 360

SPT 1700 Series Product Reference Guide

Problem

Cause(s)

Solution

Tapping the Today button doesn’t display the current date.

Your SPT 1700 terminal is not set to the current date.

Make sure the Set Date box in the General Preferences screen displays the current date. Refer to General Preferences on page 1410 for more information.

Entries seem to be missing in various applications.

The categories pick list is set for Check the Categories pick list a specific category. (upper-right corner of the screen). Choose All to display all of the records for the application.

Applications

Security may have been set for certain records.

Check the Security application and make sure that the Private Records setting is set to Show private records.

HotSync Operations A Local HotSync HotSync Manager is not operation does not running. complete successfully.

If HotSync Manager is running, exit and restart it. Make sure you selected Local from the HotSync Manager menu or the Symbol Palm Terminal Desktop menu. Check the cable connection between the SPT 1700 terminal or cradle and the serial port on your computer. Try a lower baud rate setting on the Local tab in the Setup screen. Make sure you are not running another program, such as America On-line, CompuServe or WinFax, that uses the serial port you selected in the Setup screen. Read the HotSync Log for the user account for which you are performing a HotSync operation.

20-12

Page 361

Getting Help With Your SPT 1700 Terminal

Problem

Cause(s)

A Modem HotSync Your modem doesn't have an operation does not auto-off feature enabled. complete successfully. The Setup String in the Setup screen configures your modem incorrectly. Confirm that the Speed setting in the Setup screen is appropriate for your modem.

Solution Make sure your modem is on, and that it does not shut down automatically as part of an energysaving feature. You may need to select a different Modem Type or enter a custom Setup String. Most modems have a Setup String that causes them to send initial connection sounds to a speaker. You can use these sounds to check the modem connection. Make sure the modem connected to your computer is turned on and is connected to the outgoing phone line. Make sure you selected Modem from the HotSync Manager menu.

Security I forgot the password (SPT 1700 terminal is not locked).

You can use the Security application to delete the password. If you do this, your SPT 1700 terminal deletes all entries marked as Private. However, you can perform a HotSync operation before you delete the password: the HotSync process backs up all entries, whether or not they are marked private. Refer to Changing or Deleting a Password on page 15-7 for details.

I forgot the password (SPT 1700 terminal is locked).

If you assign a password and lock your SPT 1700 terminal, perform a hard reset to continue using your SPT 1700 terminal. Refer to Resetting Your SPT 1700 Terminal on page 21-5 for details.

20-13

Page 362

SPT 1700 Series Product Reference Guide

Memo Pad Tips If you cannot manually arrange the order of the memos in the List screen, check the Memo Preferences setting. Make sure that Sort by is set to Manual. If you choose to view your memos alphabetically on Symbol Palm Terminal Desktop and then perform a HotSync operation, the memos on your SPT 1700 terminal still appear in the order defined in the Memo Preferences setting. In other words, the sort settings that you use with Symbol Palm Terminal Desktop are not transferred to your SPT 1700 terminal.

Date Book Tips In the Week View, you cannot select overlapping events that have the same start time. If you have two or more events with the same start time, choose the Day View for the particular day to see the overlapping events.

20-14

Page 363

Getting Help With Your SPT 1700 Terminal

Technical Support, Service and Repair If you have a problem using your SPT 1700 terminal, make sure you have reviewed the following: •

The Troubleshooting section earlier in this chapter

•

The README file and Help Notes located in the folder where you installed the Symbol Palm Terminal Desktop software on your computer (or on your installation CD)

•

The Symbol Palm Terminal Desktop software Online Help.

For further assistance, contact your regional technical support office by e-mail, phone or fax. Before requesting support, experiment a bit to reproduce and isolate the problem. When you do contact support, be ready to provide the following information: •

The version of Windows you are using

•

The actual error message or state you are experiencing

•

The steps you take to reproduce the problem.

Technical Support United States and Canada Phone:1-800-659-2240 Web site:http://www.symbol.com/palm Outside North America, contact your local Symbol representative. Refer to page xix for the Technical Support number in your country.

20-15

Page 364

SPT 1700 Series Product Reference Guide

20-16