The text of a manual · part 10 of 46
SPT 1700 Series Product Reference Guide: Chapter 2 Network Setup, pages 69 to 76
Pages 69 to 76 of 394, from SPT 1700 Series Product Reference Guide
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SPT-1700, Symbol SPT-1733 1734, Symbol SPT-1740 and Symbol SPT-1746
Page 69
Network Setup
Service ID Pref pick list Only SvcID
The modem will attempt to detect only the system in the Service ID parameters for registration. This is useful in cases where the user wishes to prevent roaming to any other system but his home one.
PreferSvcId The modem will first attempt to register on the system described by the SPI/WASI/SPNI entries. If no system is found, the modem will attempt to register on the remaining available systems in the area. This is useful in situations where the user spends most of his time in one area and occasionally roams. In this case, the user would enter the Network ID parameters that reflect the system he most often will register on. Another situation where this may be useful is in cases where the user has two systems in his area but prefers service on one due to rate advantages, etc. IgnoreSvcID The modem will attempt to register on any system but that reflected in the Network ID entries. This is useful in situations where the user wishes to block registration on systems in his area that he does not have an agreement with. This may speed up the registration process in some areas. Any SvcID
The SPI/WASI/SPNI entries are ignored. This is the default configuration and ensures that the modem will attempt to register on any valid system that it can find.
Hot List Operation pick list Scan All
Ignores the list of channels and search all of them.
Use List
Attempts to search for system on the channels in the list. If service cannot be found on those channels, the user will be unregistered.
Hybrid
Attempts to search for systems on the given channels first, and then opens the search up to all channels if none can be found. Given this selection, the modem will also update the channel list automatically with any channel on which it has found service. In this way, the channel list is eventually updated with all CDPD systems in the area.
2-19
Page 70
SPT 1700 Series Product Reference Guide
Status Screen The Status screen shows modem information which is updated every 3 seconds.This screen was designed to assist support personnel in diagnosing problems with your modem. If a problem develops, the Symbol Support Center (Refer to Symbol Support Centers on page -xix for contact information) will find the information displayed here of importance.
Note: There are no menus on this screen and no place for user entry. Tapping Done will return you to the Quick Status screen. CDPD Entry identifies the current CDPD acquisition state.
2-20
SEARCH
The modem is searching for service.
ACQ'D
The modem has acquired or synchronized to a CDPD system in the area.
Page 71
Network Setup
RSSI Entry is the signal strength measured on the current channel. During the SEARCH phase of operation, this value may vary according to the channel on which an attempt will be made. When ACQ'D, the signal strength measurement should remain somewhat constant. Color
Area color code being transmitted by the CDPD system.
Chan
The current channel. During the SEARCH phase, this value may change according to the channel that is being attempted. Once a channel has been ACQ'D, this should remain relatively constant.
CellID
CDPD Base Station identifier number.
BLER
A measurement of the error rate on the forward channel detected by the modem.
Side
Display of the current Side, given the A/B side distribution of the CDPD channels.
PL
The current Power Level value at which transmission will take place.
SPI
The current CDPD Base Station Service Provider Identifier.
WASI
The current CDPD Base Station Wide Area Service Identifier.
SPNI
The current CDPD Base Station Service Provider Network Identifier.
PwrProd
The Power Product value transmitted by the current CDPD system.
RegErr
A numeric value representing the last registration error encountered. A value of 1-7 indicates an error; a value of 0 indicates no error and a value of 255 indicates no registration attempt was made.
Link
Identifies the current CDPD communication link state. Can be Locked or Searching.
IP is the IP address of the unit. EID is the Equipment ID of the unit.
2-21
Page 72
SPT 1700 Series Product Reference Guide
Terminal Screen The Terminal provides an internal terminal emulator for communication with the modem, allowing users to further customize the operation of their modem based on the AT command set.
To begin a terminal session: 1. Tap the Online button. Going online terminates any active network session and establishes a serial session to the modem. The screen shows the data that is being received from the modem. As data is received, it is displayed line by line on the screen display. Scroll bars automatically display when the amount of displayed data exceeds the physical size of the SPT 1733 terminal’s total display area. You can scroll back and forth through most of the previously displayed data. There is a physical limitation on how much previous data can be scrolled and once this limitation is reached, the oldest data will be overwritten, so the screen buffer always maintains the last 2000 bytes of data from the modem. 2. Tap Offline button to close the serial session. 3. Tap Done to terminate any serial session and re-establish a network session, returning you to the Quick Status screen. 4. Tap the Clear button to clear the current screen buffer. At the bottom of the screen is a field for entry of an AT command. There are a number of pre-defined commands that are included in the Cmd pick list. When you selection of any of these commands, the modem will automatically send the command, without the need to press Send button.
2-22
Page 73
Network Setup
Ping Screen From this screen you can send a PING request to another network device whose network address you already know. This is useful to verify network connectivity.
As with other PING applications, you must enter the IP address of the other network device in the IP field and then select the desired payload size. Pressing the Send button will send the PING. A status line will provide information on whether or not the PING was successful by displaying a "Success" or "Fail" message. There is a 20 second timeout for a response before a "Success" or "Fail" message may display. Please note that there are some limitations on this PING implementation: •
The size of PING payload is limited to 99 bytes. If a payload of greater than that is entered, a data error message will be displayed.
•
The delay to wait for response is fixed at 20 seconds.
After you have viewed this information, press the OK button to return to the Quick Status screen.
2-23
Page 74
SPT 1700 Series Product Reference Guide
Help Menu The Help menu shows basic information about your modem, modem driver, and Merlin application.
Modem Info
Displays the Quick Status screen. Refer to 2-13 for details.
Driver Info
Displays the version of the modem driver.
About
Displays version and copyright information for Merlin.
2-24
Page 75
Network Setup
Configuring a GSM WAN Connection (SPT 1734 Only) To set up a new connection configuration: 1. Tap the icon to open the Applications Launcher.
2. Tap the icon to open the HotSync application.
3. Tap the icon to display the HotSync Options menu and select Connection Setup.The Connection Preferences screen displays:
4. Tap New to create a new configuration. The Edit screen displays:
5. Enter a name for the connection (i.e., GSM modem) and select GSM Driver to Modem as the Connection Method. Refer to Preparing Your SPT 1700 Terminal for a Modem HotSync Operation on page 9-15 for additional information about this screen. 6. Tap the OK button, followed by the Done button.
2-25
Page 76
SPT 1700 Series Product Reference Guide
2-26