The text of a manual · part 9 of 12
Spectrum One Serial Access Bridge (SAB) II Programmer's Reference Guide: Chapter 3 BAR Reference, pages 63 to 72
Pages 63 to 72 of 94, from Spectrum One Serial Access Bridge (SAB) II Programmer's Reference Guide
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Symbol SAB-Lite
Page 63
BAR Reference
The data length header field (bytes 2 and 3) specifies a length of 20 (0x14), the actual length of the three ASCII, NULL-terminated strings returned for the date, time and day. The date is returned in the first string, the time is returned in the second string and the day is returned in the third, all as ASCII, NULL-terminated strings with the following formats: mm-dd-yy mm– represents month (01-12) dd – represents day (01-31) yy – represents year (80-79) (19802079)
hh:mm:ss hh – represents hour (00-23) mm – represents minutes (00-59) ss – represents seconds (00-59)
d d – represents day (0-6) (0 is Sunday) Table 3-29. Get Host Date and Time Return Codes
Value 0x00 0x01 0x05 0x06
Name BAR_RTN_OK BARERR_BADPAK BARERR_OPERATIO N BARERR_UNKNOWN
Description good return invalid packet host operation error occurred unimplemented BAR error
3-21
Page 64
SAB II - Programmer’s Reference Guide
Administrative BARs The SAB and Spectrum One network require certain administrative functions be performed. The administrative BARs fulfill the SAB remote operational requirements. The administrative BARs exist on both the host and the SAB and provide the following functions: • standardized interface between the host and the SAB • network command and control: • examine/change radio channels • examine/remove terminals • examine/remove transceivers • restart • get topology • get/clear statistics • get SAB version. The SAB processes all administrative commands in the server mode. The host issues command packets to the SAB. The SAB issues response packets when command processing completes. When a command is processed a response to the host is always returned.
3-22
Page 65
BAR Reference
Get Units Requests unit numbers as bit-field information for assigned terminals and transceivers. Table 3-30. Get Units Command Packet
Byte Value 0 VAR
Description flags
1 2 3 4 5 6 7 command code data length data length function code subfunction code message length message length
0x40 0x00 0x00 0x00 0x20 0x00 0x00
Details bit 0= 1 command packet bit 1-7 reserved BAR_ADMIN
FUNC_GETINFO SFUNC_UNITS LSB MSB
No data field is sent with this packet. Table 3-31. Get Units Response Packet
Byte Value 0 VAR 1 2 3 4 5 6 7
VAR VAR VAR 0x00 0x20 VAR VAR
Description flags
Details bit 0 = 0 response packet bit 1-7 reserved return code Refer to Table 3-32 data length LSB data length MSB function code FUNC_GETINFO subfunction code SFUNC_UNITS message length LSB message length MSB
The data field returned with this packet is a bit-field form containing information on currently assigned remote unit numbers. The data is formatted into 512 bits (64 bytes) with each bit representing a transceiver or remote.
3-23
Page 66
SAB II - Programmer’s Reference Guide
Transceivers are assigned numbers (and corresponding bits) in the 1 to 63 range. Remotes are in the 65 to 511 range. A unit number of 0 is assigned to uninitialized transceivers and a unit number is 64 is assigned to uninitialized remotes. Table 3-32. Get Units Return Codes
Value 0x00 0x01
3-24
Name BAR_RTN_OK BARERR_BADPAK
Description good return invalid packet
Page 67
BAR Reference
Delete Specific Remote Units Requests SAB remove assigned remote units specified in the command packet data field. Table 3-33. Delete Specific Remote Units Command Packet
Byte Value 0 VAR 1 2 3 4 5 6 7
0x40 VAR VAR 0x01 0x21 VAR VAR
Description flags
Details bit 0 = 1 command packet bit 1-7 reserved command code BAR_ADMIN data length LSB data length MSB function code FUNC_SETINFO subfunction code SFUNC_DELUNITS message length LSB message length MSB
The data field contains the all remotes unit numbers selected for removal from the current configuration. The data is formatted as a unsigned-integer variable number (2 bytes each) that represent the unit numbers to delete. The entire packet is rejected if the numbers do not range from 65 to 511. Table 3-34. Delete Specific Remote Units Response Packet
Byte Value 0 VAR 1 2 3 4 5 6 7
VAR 0x00 0x00 0x01 0x21 0x00 0x00
Description flags bit 1-7 return code data length data length function code subfunction code message length message length
Details bit 0 = 0 response packet reserved Refer to Table 3-35
FUNC_SETINFO SFUNC_DELUNITS
3-25
Page 68
SAB II - Programmer’s Reference Guide
No data field returns with this response. Table 3-35. Delete Specific Remote Units Return Codes
Value 0x00 0x01 0x02
3-26
Name BAR_RTN_OK BARERR_BADPAK BAREER_BADDATA
Description good return invalid packet invalid unit number
Page 69
BAR Reference
Get Radio Frequencies Requests SAB return the currently defined radio channels and associated signal strengths. The channels are previously selected by default or using the SSP.INI file to define them. Table 3-36. Get Radio Frequencies Command Packet
Byte Value 0 VAR
Description flags
1 2 3 4 5 6 7 command code data length data length function code FUNC_GETINFO subfunction code SFUNC_RADIO message length message length
0x40 0x00 0x00 0x00 0x02 0x00 0x00
Details bit 0 = 1 command packet bit 1-7 reserved BAR_ADMIN
No data field is sent with this packet. Table 3-37. Get Radio Frequencies Response Packet
Byte Value 0 VAR 1 2 3 4 5 6 7
VAR VAR VAR 0x00 0x02 VAR VAR
Description flags
Details bit 0 = 0 response packet bit 1-7 reserved return code Refer to Table 3-38 data length LSB data length MSB function code FUNC_GETINFO subfunction code SFUNC_RADIO message length LSB message length MSB
The data within this packet returns in an ordered fashion, the 12 defined frequencies used for the remote-to-transceiver and transceiver-to-transceiver radio channels. The 2 primary data structures are defined below.
3-27
Page 70
SAB II - Programmer’s Reference Guide
The CHANNEL data structure contains, in Byte 0, the channel number currently in use along with its signal quality index in bytes 1-2. The higher the signal quality value, the quieter the channel. The SETRADIO data structure contains the 12 defined frequencies in a CHANNEL type array. The first six defined channels are for remote-to-transceiver radio, and the latter six channels are for transceiver-to-transceiver. The user selection frequencies are contained in the following two bytes, transceiver-to-remote and transceiver-to-transceiver respectively. Table 3-38. Get Radio Frequencies Return Codes
Value 0x00 0x01
3-28
Name BAR_RTN_OK BARERR_BADPAK
Description good return invalid packet
Page 71
BAR Reference
Select New Remote Frequency Requests SAB assign the specified radio channel as the "in-use" channel for remote-totransceiver and transceiver-to-transceiver radio communication. The specified frequency is one of the currently defined 6 frequencies allowed for use. Use the Get Radio Frequency to obtain the set of 6 available frequencies. Table 3-39. Select New Remote Frequency Command Packet
Byte Value 0 VAR 1 2 3 4 5 6 7
0x40 VAR VAR 0x01 0x02 VAR VAR
Description flags
Details bit 0 = 1 command packet bit 1-7 reserved command code BAR_ADMIN data length LSB data length MSB function code FUNC_SETINFO subfunction code SFUNC_RADIO message length LSB message length MSB
The data field contains two bytes for the selected frequency. An error is generated if the frequency selected is not one of the currently defined frequency sets. Five minutes before a frequency change, the system notifies all transceivers and listening terminals. If only one frequency field is changed, others can be set to zero. Byte 0 is the transceiver-to-remote channel and byte 1 is the transceiver-to-transceiver channel.
3-29
Page 72
SAB II - Programmer’s Reference Guide Table 3-40. Select New Remote Frequency Response Packet
Byte Value 0 VAR
Description flags
1 2 3 4 5 6 7 return code data length data length function code FUNC_SETINFO subfunction code SFUNC_RADIO message length message length
VAR 0x00 0x00 0x01 0x02 0x00 0x00
Details bit 0 = 0 response packet bit 1-7 reserved Refer to Table 3-41
No data field returns with this response. Table 3-41. Select New Remote Frequency Return Codes
Value 0x00 0x01 0x02
3-30
Name BAR_RTN_OK BARERR_BADPAK BAREER_BADDATA
Description good return invalid packet invalid channel specified