Chapter 2 Function Definitions Introduction This chapter details all of the available function calls and their descriptions (see Table 2-1 for a complete list). All CSP functions listed are broken down by functional group. Table 2-1. Available Function Calls Function Name

Description

Page

Basic Function Commands disable

Terminates a connection with the scanner.

2-5 enable

Establishes a connection with the scanner.

2-6 getCodeType

Returns the code type of barcode scanned.

2-7 isEnabled

Determines if the scanner is currently enabled and ready for use.

2-9 resetScanner

Reconfigures the scanner to the factory default settings.

2-10 setDataTransFormat

Determines the format of the decoded data which is returned to the application.

2-11 setLaserOnTime

Sets the amount of time the decoder will try to decode a barcode.

2-12 setLinearSecurity

Determines which linear code types and lengths must be read, 2-13 depending on the security level.

setPrefix

Set the hex value of the character to be used as the prefix to any decoded data.

2-15

2-1

Page 16

PSM20i Bar Code Scanner Attachment Programmer’s Guide

Table 2-1. Available Function Calls Function Name

Description

Page setSuffix1

Set the hex value of the character to be used as the first suffix 2-16 to any decoded data.

setSuffix2

Set the hex value of the character to be used as the second suffix to any decoded data.

2-17 startDecode

Returns a string containing the decoded text.

2-18 transmitCodeId

Returns an ID character along with the decoded barcode data. 2-19

Decode Configuration Commands booklandEAN

Enable or disable decoding of Bookland-EAN barcodes and set label options.

2-20 codabar

Enable or disables decoding of Codabar bar codes and options.

2-21 code128

Enable or disables decoding of USS-128 bar codes.

2-23 code39

Enable or disables decoding of Code 39 bar codes and options.

2-24 code39Trioptic

Enable or disables decoding of Trioptic Code 39 bar codes.

2-26 code93

Enable or disables decoding of Code 93 bar codes and lengths.

2-27 discrete2of5

Enable or disables decoding of Discrete 2 Of 5 bar codes and 2-28 lengths.

ean128

Enable or disables decoding of UCC/EAN-128 bar codes.

ean13

Enable or disable decoding of EAN-13 barcodes and set label 2-31 options.

ean8

Enable or disable decoding of EAN-8 barcodes and set label options.

2-32 interleaved2of5

Enable or disables decoding of Interleaved 2 Of 5 bar codes and options.

2-33 isbt128

Enable or disables decoding of ISBT-128 bar codes.

2-35 msiPlessey

Enable or disables decoding of MSI Plessey bar codes and options.

2-36

2-2

2-30

Page 17

Function Definitions

Table 2-1. Available Function Calls Function Name

Description

Page upcA

Enable or disable decoding of UPC-A barcodes and set label options.

2-38 upcE

Enable or disable decoding of UPC-E barcodes and set label options.

2-39 upcE1

Enable or disable decoding of UPC-E1 barcodes and set label 2-40 options.

upcEANCouponCode

Enable or disables decoding of UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 supplemental characters, and UPC-A/EAN-128 bar codes.

2-41 upcEANSecurity

Set the level of security for decoding UPC/EAN bar codes.

2-42 upcEANSupplemental

Set supplemental mode for UPC/EAN labels.

2-43 upcEANSupplRedundancy Adjust the number of times a symbol without supplementals will be decoded before transmission.

2-44

Miscellaneous getSDKVersion

Returns the version of the SDK that was used in creating the midlet.

2-45

Please note, the returned data from each function, if false, indicates an error condition in executing the function, except for errors reported from Windows file operations. A true indicates success and/or returned data as detailed by each function description.

2-3

Page 18

PSM20i Bar Code Scanner Attachment Programmer’s Guide

Supported Barcode Type The following bar codes types can be scanned with the PSM20i Bar Code Scanner Attachment:

2-4

Barcode Type

Default Setting on Scanner

UPC-A

Enable

UPC-E

Enable

UPC-E1

Disable

EAN-8

Enable

EAN-13

Enable

EAN-128

Enable

Code 39

Enable

Trioptic Code 39

Disable

Code 93

Disable

Code 128

Enable

ISBT-128

Enable

Bookland EAN

Disable

Interleave 2 of 5

Enable

Discrete 2 of 5

Disable

MSI Plessey

Disable

Codabar

Disable

Coupon Code

Disable

Page 19

Function Definitions

Basic Function Commands disable Class BarCodeReader

Description Terminates a connection with the scanner.

Invocation boolean disable()

Return Value true if connection to scanner was successfully disabled.

false if connection to scanner failed.

Example import com.symbol.j2me.midlets.ascanner.BarCodeReader; BarCodeReader barCodeReader = new BarCodeReader(); boolean response = barCodeReader.disable();

2-5

Page 20

PSM20i Bar Code Scanner Attachment Programmer’s Guide enable Class BarCodeReader

Description Establishes a connection with the scanner. This function must be successfully executed prior to calling any other function calls. Note: To guarantee an accurate decode, ensure that the enable function is not called while the phone is transmitting.

Invocation boolean enable()

Return Value true if connection to scanner was successfully enabled.

false if connection to scanner failed.

Example import com.symbol.j2me.midlets.ascanner.BarCodeReader; BarCodeReader barCodeReader = new BarCodeReader(); boolean response = barCodeReader.enable();

2-6

Page 21

Function Definitions getCodeType Class BarCodeReader

Description Returns the code type of barcode scanned.

Invocation byte getCodeType()

2-7

Page 22

PSM20i Bar Code Scanner Attachment Programmer’s Guide

Return Value Returns a byte representing the type of barcode scanned. Below is a list of associated hex values for each supported code type: Barcode Type

Hex Value

Barcode Type

Hex Value

Not Applicable

0x00

EAN-8 + 5 Supps.

0x8A

Bookland EAN

0x16

Interleave 2 of 5

0x06

Codabar

0x02

ISBT 128 Concat.

0x21

Code 128

0x03

ISBT-128

0x19

Code 39

0x01

MSI Plessey

0x0E

Code 39 Full ASCII

0x13

Trioptic Code 39

0x15

Code 93

0x07

UPC-A

0x08

Coupon Code

0x17

UPC-A + 2 Supps.

0x48

Discrete 2 of 5

0x04

UPC-A + 5 Supps.

0x88

EAN-128

0x0F

UPC-E

0x09

EAN-13

0x0B

UPC-E + 2 Supps.

0x49

EAN-13 + 2 Supps.

0x4B

UPC-E + 5 Supps.

0x89

EAN-13 + 5 Supps.

0x8B

UPC-E1

0x10

EAN-8

0x0A

UPC-E1 + 2 Supps.

0x50

EAN-8 + 2 Supps.

0x4A

UPC-E1 + 5 Supps.

0x90

Value is 0x00 if the scanner is disabled or no barcode has been scanned.

Example import com.symbol.j2me.midlets.ascanner.BarCodeReader; BarCodeReader barCodeReader = new BarCodeReader(); byte codeType = barCodeReader.getCodeType();

2-8

Page 23

Function Definitions isEnabled Class BarCodeReader

Description Determines if the scanner is currently enabled and ready for use.

Invocation boolean isEnabled()

Return Value true if scanner is enabled false if scanner is not enabled

Example import com.symbol.j2me.midlets.ascanner.BarCodeReader; BarCodeReader barCodeReader = new BarCodeReader(); boolean response = barCodeReader.isEnabled();

2-9

Page 24

PSM20i Bar Code Scanner Attachment Programmer’s Guide resetScanner Class BarCodeReader

Description Reconfigures the scanner to the factory default settings. Any application applied configurations will be lost.

Invocation boolean resetScanner()

Return Value true scanner was reset successfully.

false failed to reset scanner.

Example import com.symbol.j2me.midlets.ascanner.BarCodeReader; BarCodeReader barCodeReader = new BarCodeReader(); boolean response = barCodeReader.resetScanner(); Sets the scanner back to its factory configuration.

2-10