Page 289

Appendix E PPT 4300 with Integrated Scanner (PPT4300-SOE) Appendix Contents The SE 1223 Scan Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 SE 1223 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 Decode Zone (Vcc = 5V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 Default Scanner Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5

E-1

Page 290

PPT 4300 Series Product Reference Guide

E-2

Page 291

PPT 4300 with Integrated Scanner (PPT4300-SOE)

The SE 1223 Scan Engine Overview The PPT 4300-S0E terminal is equipped with an integrated scanning module. The scanner laser engine model is SE 1223. This is a miniature visible-laser based scan engine that scans and processes bar codes into ASCII data. The scan engine default settings are shown in Table E-2. For more detailed SE 1223 scan engine information, contact your Symbol support representative.

SE 1223 Technical Specifications Table E-1. SE 1223 Technical Specifications Item

Description

Scan Repetition Rate

35 (± 5) scans/sec (bidirectional)

Laser Power

0.8 mW ± 10%, 670 nm

Print Contrast minimum 20% absolute dark/light reflectance measured at 675 nm.

Scan Angle

42° ± 2°

Skew Tolerance

± 65° from normal (see Figure E-1 on page E-4)

Pitch Angle

± 55° from normal (see Figure E-1 on page E-4)

Roll

± 20° from vertical (see Figure E-1 on page E-4)

Decode Depth of Field

See Figure E-1 on page E-4.

Ambient Light Immunity Sunlight Artificial Light

8,000 ft. candles 450 ft. candles

Laser Class

Intended use in CDRH/IEC Class 2 devices.

Operating Temperature

-22° to 131°F

-30° to 55°C

Storage Temperature

-40° to 140°F

-40° to 60°C

Humidity

5% to 95% non-condensing

86,112 lux 4,844 lux

Note: The scanner interrupts the terminal’s radio transmission for up to three seconds. This does not affect the session with the host.

E-3

Page 292

PPT 4300 Series Product Reference Guide

Decode Zone (Vcc = 5V) The standard SE 1223 decodes the symbols as shown in Figure E-1 The figures shown are typical values. The minimum element width (or “symbol density”) is the width in mils of the narrowest bar or space in the symbol. The maximum usable length of a symbol at any given range is shown below.

SE 1223

In.

Cm

13.83

35.1

10

25.4

5

12.7

0

0

5

12.7

10

25.4

13.83

35.1

5 mil 3

5 7.5 mil

9

13 mil

2.5

13 15 mil

20

20 mil

22 40 mil

30

* 55 mil

In. 0 Cm 0

5 12.7

10 25.4

15 38.1

36

20 50.8

25 63.5

30 76.2

Depth of Field *Minimum distance determined by symbol length and scan angle

Figure E-1. Decode Zone

E-4

36 91.4

W i d t h o f F i e l d

Page 293

PPT 4300 with Integrated Scanner (PPT4300-SOE)

Default Scanner Settings The SE 1223 is shipped with the default settings shown in Table E-2, below. Scanner parameter values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change scanner settings for some parameters by scanning the appropriate bar codes. The new values replace the default settings in memory. Scanning the SET ALL DEFAULTS bar code resets all parameters to their default settings. To change the setting for any allowed options, contact your Symbol representative to get the correct configuration bar codes. Do not change the Serial or Event Reporting Parameters or the scanner will be disabled. Table E-2 Default Settings

Category

Parameter

Default

General Settings

Set Default Parameter

All Defaults

Notes

Beeper Tone

Medium Frequency

Cannot be changed.

Laser On Time

3.0 sec

Cannot be changed.

Aim Duration

0.0 sec

Not supported with the standard scanner module.

Power Mode

Low Power

Will be set to Low Power by the kbwedge.com

Trigger Mode

Level

Do not change this option.

Time-out Between Same Symbol

1.0 sec

Beep After Good Decode

Enable

Transmit “No Read” Message

Disable

Cannot be changed using bar codes, but you can change it by running kbwedge.com from the command line with the / nosound option.

E-5

Page 294

PPT 4300 Series Product Reference Guide

Table E-2 Default Settings

Category General Settings

UPC/EAN

E-6

Parameter

Default

Parameter Scanning

Enable

Linear Code Type Security Levels

1

Bi-directional Redundancy

Disable

UPC-A

Enable

UPC-E

Enable

UPC-E1

Disable

EAN-8

Enable

EAN-13

Enable

Bookland EAN

Disable

Decode UPC/EAN Supplementals

Ignore

Decode UPC/EAN Supplemental Redundancy

7

Transmit UPC-A Check Digit

Enable

Transmit UPC-E Check Digit

Enable

Transmit UPC-E1 Check Digit

Enable

UPC-A Preamble

System Character

UPC-E Preamble

System Character

UPC-E1 Preamble

System Character

Convert UPC-E to A

Disable

Convert UPC-E1 to A

Disable

Notes

Page 295

PPT 4300 with Integrated Scanner (PPT4300-SOE)

Table E-2 Default Settings

Category UPC/EAN

Code 128

Code 39

Code 93

Parameter

Default

EAN-8 Zero Extend

Disable

Convert EAN-8 to EAN-13 Type

Type is EAN-13

UPC/EAN Security Level

0

UPC/EAN Coupon Code

Disable

USS-128

Enable

UCC/EAN-128

Enable

ISBT 128

Enable

Code 39

Enable

Trioptic Code 39

Disable

Convert Code 39 to Code 32

Disable

Code 32 Prefix

Disable

Set Length(s) for Code 39

2-55

Code 39 Check Digit Verification

Disable

Transmit Code 39 Check Digit

Disable

Code 39 Full ASCII Conversion

Disable

Code 93

Disable

Set Length(s) for Code 93

4-55

Notes

E-7

Page 296

PPT 4300 Series Product Reference Guide

Table E-2 Default Settings

Category Interleaved 2 of 5

Parameter

Default

Interleaved 2 of 5

Enable

Set Length(s) for I 2 of 5

Discrete 2 of 5

I 2 of 5 Check Digit Verification

Disable

Transmit I 2 of 5 Check Digit

Disable

Convert I 2 of 5 to EAN 13

Disable

Discrete 2 of 5

Disable

Set Length(s) for D 2 of 5 Codabar

MSI Plessey

E-8

14

12

Codabar

Disable

Set Lengths for Codabar

5-55

CLSI Editing

Disable

NOTIS Editing

Disable

MSI Plessey

Disable

Set Length(s) for MSI Plessey

6-55

MSI Plessey Check Digits

One

Transmit MSI Plessey Check Digit

Disable

MSI Plessey Check Digit Algorithm

Mod 10/Mod 10

Notes

Page 297

PPT 4300 with Integrated Scanner (PPT4300-SOE)

Table E-2 Default Settings

Category

Parameter

Data Options

Transmit Code ID Character Prefix/Suffix Values Prefix Suffix 1 Suffix 2 Scan Data Transmission Format

Serial Interface

Event Reporting

Default

Notes

None

NULL LF CR Data as is

Baud Rate

9600

Parity

None

Software Handshaking

Enable

Decode Data Packet Format

Unpacketed

Host Serial Response Time-out

2 sec

Stop Bit Select

1

Intercharacter Delay

0

Host Character Timeout

200 msec

Decode Event

Disable

Boot Up Event

Disable

Parameter Event

Disable

Do not change any of these Serial Interface settings or the scanner will be disabled.

Do not change any of these Event Reporting settings or the scanner will be disabled.

E-9

Page 298

PPT 4300 Series Product Reference Guide

E-10