The text of a manual · part 35 of 37
PPT 4300 Series Product Reference Guide: Appendix E PPT 4300 with Integrated Scanner (PPT4300-SOE)
Pages 289 to 298 of 326, from PPT 4300 Series Product Reference Guide
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PPT-4340
Page 289
Appendix E PPT 4300 with Integrated Scanner (PPT4300-SOE) Appendix Contents The SE 1223 Scan Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 SE 1223 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 Decode Zone (Vcc = 5V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 Default Scanner Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5
E-1
Page 290
PPT 4300 Series Product Reference Guide
E-2
Page 291
PPT 4300 with Integrated Scanner (PPT4300-SOE)
The SE 1223 Scan Engine Overview The PPT 4300-S0E terminal is equipped with an integrated scanning module. The scanner laser engine model is SE 1223. This is a miniature visible-laser based scan engine that scans and processes bar codes into ASCII data. The scan engine default settings are shown in Table E-2. For more detailed SE 1223 scan engine information, contact your Symbol support representative.
SE 1223 Technical Specifications Table E-1. SE 1223 Technical Specifications Item
Description
Scan Repetition Rate
35 (± 5) scans/sec (bidirectional)
Laser Power
0.8 mW ± 10%, 670 nm
Print Contrast minimum 20% absolute dark/light reflectance measured at 675 nm.
Scan Angle
42° ± 2°
Skew Tolerance
± 65° from normal (see Figure E-1 on page E-4)
Pitch Angle
± 55° from normal (see Figure E-1 on page E-4)
Roll
± 20° from vertical (see Figure E-1 on page E-4)
Decode Depth of Field
See Figure E-1 on page E-4.
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles 450 ft. candles
Laser Class
Intended use in CDRH/IEC Class 2 devices.
Operating Temperature
-22° to 131°F
-30° to 55°C
Storage Temperature
-40° to 140°F
-40° to 60°C
Humidity
5% to 95% non-condensing
86,112 lux 4,844 lux
Note: The scanner interrupts the terminal’s radio transmission for up to three seconds. This does not affect the session with the host.
E-3
Page 292
PPT 4300 Series Product Reference Guide
Decode Zone (Vcc = 5V) The standard SE 1223 decodes the symbols as shown in Figure E-1 The figures shown are typical values. The minimum element width (or “symbol density”) is the width in mils of the narrowest bar or space in the symbol. The maximum usable length of a symbol at any given range is shown below.
SE 1223
In.
Cm
13.83
35.1
10
25.4
5
12.7
0
0
5
12.7
10
25.4
13.83
35.1
5 mil 3
5 7.5 mil
9
13 mil
2.5
13 15 mil
20
20 mil
22 40 mil
30
* 55 mil
In. 0 Cm 0
5 12.7
10 25.4
15 38.1
36
20 50.8
25 63.5
30 76.2
Depth of Field *Minimum distance determined by symbol length and scan angle
Figure E-1. Decode Zone
E-4
36 91.4
W i d t h o f F i e l d
Page 293
PPT 4300 with Integrated Scanner (PPT4300-SOE)
Default Scanner Settings The SE 1223 is shipped with the default settings shown in Table E-2, below. Scanner parameter values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change scanner settings for some parameters by scanning the appropriate bar codes. The new values replace the default settings in memory. Scanning the SET ALL DEFAULTS bar code resets all parameters to their default settings. To change the setting for any allowed options, contact your Symbol representative to get the correct configuration bar codes. Do not change the Serial or Event Reporting Parameters or the scanner will be disabled. Table E-2 Default Settings
Category
Parameter
Default
General Settings
Set Default Parameter
All Defaults
Notes
Beeper Tone
Medium Frequency
Cannot be changed.
Laser On Time
3.0 sec
Cannot be changed.
Aim Duration
0.0 sec
Not supported with the standard scanner module.
Power Mode
Low Power
Will be set to Low Power by the kbwedge.com
Trigger Mode
Level
Do not change this option.
Time-out Between Same Symbol
1.0 sec
Beep After Good Decode
Enable
Transmit “No Read” Message
Disable
Cannot be changed using bar codes, but you can change it by running kbwedge.com from the command line with the / nosound option.
E-5
Page 294
PPT 4300 Series Product Reference Guide
Table E-2 Default Settings
Category General Settings
UPC/EAN
E-6
Parameter
Default
Parameter Scanning
Enable
Linear Code Type Security Levels
1
Bi-directional Redundancy
Disable
UPC-A
Enable
UPC-E
Enable
UPC-E1
Disable
EAN-8
Enable
EAN-13
Enable
Bookland EAN
Disable
Decode UPC/EAN Supplementals
Ignore
Decode UPC/EAN Supplemental Redundancy
7
Transmit UPC-A Check Digit
Enable
Transmit UPC-E Check Digit
Enable
Transmit UPC-E1 Check Digit
Enable
UPC-A Preamble
System Character
UPC-E Preamble
System Character
UPC-E1 Preamble
System Character
Convert UPC-E to A
Disable
Convert UPC-E1 to A
Disable
Notes
Page 295
PPT 4300 with Integrated Scanner (PPT4300-SOE)
Table E-2 Default Settings
Category UPC/EAN
Code 128
Code 39
Code 93
Parameter
Default
EAN-8 Zero Extend
Disable
Convert EAN-8 to EAN-13 Type
Type is EAN-13
UPC/EAN Security Level
0
UPC/EAN Coupon Code
Disable
USS-128
Enable
UCC/EAN-128
Enable
ISBT 128
Enable
Code 39
Enable
Trioptic Code 39
Disable
Convert Code 39 to Code 32
Disable
Code 32 Prefix
Disable
Set Length(s) for Code 39
2-55
Code 39 Check Digit Verification
Disable
Transmit Code 39 Check Digit
Disable
Code 39 Full ASCII Conversion
Disable
Code 93
Disable
Set Length(s) for Code 93
4-55
Notes
E-7
Page 296
PPT 4300 Series Product Reference Guide
Table E-2 Default Settings
Category Interleaved 2 of 5
Parameter
Default
Interleaved 2 of 5
Enable
Set Length(s) for I 2 of 5
Discrete 2 of 5
I 2 of 5 Check Digit Verification
Disable
Transmit I 2 of 5 Check Digit
Disable
Convert I 2 of 5 to EAN 13
Disable
Discrete 2 of 5
Disable
Set Length(s) for D 2 of 5 Codabar
MSI Plessey
E-8
14
12
Codabar
Disable
Set Lengths for Codabar
5-55
CLSI Editing
Disable
NOTIS Editing
Disable
MSI Plessey
Disable
Set Length(s) for MSI Plessey
6-55
MSI Plessey Check Digits
One
Transmit MSI Plessey Check Digit
Disable
MSI Plessey Check Digit Algorithm
Mod 10/Mod 10
Notes
Page 297
PPT 4300 with Integrated Scanner (PPT4300-SOE)
Table E-2 Default Settings
Category
Parameter
Data Options
Transmit Code ID Character Prefix/Suffix Values Prefix Suffix 1 Suffix 2 Scan Data Transmission Format
Serial Interface
Event Reporting
Default
Notes
None
NULL LF CR Data as is
Baud Rate
9600
Parity
None
Software Handshaking
Enable
Decode Data Packet Format
Unpacketed
Host Serial Response Time-out
2 sec
Stop Bit Select
1
Intercharacter Delay
0
Host Character Timeout
200 msec
Decode Event
Disable
Boot Up Event
Disable
Parameter Event
Disable
Do not change any of these Serial Interface settings or the scanner will be disabled.
Do not change any of these Event Reporting settings or the scanner will be disabled.
E-9
Page 298
PPT 4300 Series Product Reference Guide
E-10