Page 215
Chapter 11 Diagnostic Tests Chapter Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Using the PPT 4300 Utilities PC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 Utilities Card Menus and Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 Diagnostic Test Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6 Summary of Diagnostic Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-7
11-1
Page 216
PPT 4300 Series Product Reference Guide
11-2
Page 217
Diagnostic Tests
Overview The PPT 4300 Utilities PC card is a bootable PC card that contains !
copies of all of the terminal’s factory-installed software and configuration files
!
batch files for formatting PC cards and rebuilding the internal flash file system
!
CardSoft software
!
diagnostic utilities
!
a complete distribution of ROM-DOS
This chapter describes how to use the card and the diagnostic utilities. For a complete list of files and ROM-DOS commands, see Appendix D, PPT 4300 Software Files. You can use the PPT 4300 Utilities PC Card to: !
replace or add software, upgrade the BIOS or rebuild the internal flash file system. You can also use it to format PC cards. See Chapter 3, Software Installation for instructions.
!
access ROM-DOS commands and utilities that may not be available on the terminal.
!
diagnose and solve problems on the terminal.
For information on the software loaded onto the terminal, see Operating System and Software on page 2-6. For information on the RF/AP diagnostic utility, see page 10-19. Note: If you make changes at the Control Panel, be aware of what drive you are currently on. The Control Panel saves some parameters to files on the current drive. The current drive is identified in the DOS prompt. The C: drive may be the internal flash drive or the PPT 4300 Utilities PC card, depending on how you booted the terminal.
11-3
Page 218
PPT 4300 Series Product Reference Guide
Using the PPT 4300 Utilities PC Card To use the PPT 4300 Utilities PC card: 1. Remove the rubber plug from the Expansion Slot at the top of the terminal and insert the PPT 4300 Utilities PC card, connector edge first. 2. Boot the terminal from the PC card. 3. The terminal boots to the Utilities Card Main Menu on the PC card. If it does not: a. The card may not be fully seated in the slot or it may be in backwards, or b. The PC Card Boot option may be disabled. See System Options on page 6-17. 4. Use the options or utilities that you need and take any action necessary. When you finish using the PC card, exit to a DOS prompt, type off and press <Enter>. 5. Look into the Expansion Slot at the top of the terminal and press the square black button to partially eject the card. Then pull out the card and replace the rubber plug.
Utilities Card Menus and Files When you first boot from the Utilities card, you will be prompted to select a keyboard type, as shown in Figure 11-1. If you select 2, the software allows you to select from a list of international keyboards. After five seconds, the default choice is activated (Standard US Keyboard), and the next menu appears, as shown in Figure 11-2. ROM_DOS Startup Menu
Time Remaining: 5
1. Standard US Keyboard 2. International Keyboard Enter Choice: 1
F5=Bypass Startup Files F6=Confirm each CONFIG line [N]
Figure 11-1. Utilities Card Keyboard Selection
11-4
Page 219
Diagnostic Tests
Utility Card Main Menu
1) Software Installation Menu 2) Diagnostic Tests Menu 3) Inverse Video On/Off E) Exit to DOS
Choose a menu item [1,2,3,E]?_
Figure 11-2. Utility Card Main Menu Software Installation Menu: Use this option for rebuilding the flash file system, installing or removing software, or loading a new BIOS. Aso see Chapter 3, Software Installation. Diagnostic Tests Menu: Use this option for running the diagnostic test utilities. Inverse Video On/Off: This option allows you to invert the colors shown on the display screen. Under some lighting conditions, this may make the screen easier to read.
11-5
Page 220
PPT 4300 Series Product Reference Guide
Diagnostic Test Utilities The PPT 4300 Utilities PC card has a number of diagnostic utilities available to help you troubleshoot and solve problems on the terminal. There are diagnostic tests for: ! ! ! ! ! ! ! !
System Board Memory Com Port IrDA Port Video Controller Keyboard Battery Radio
To carry out the diagnostic tests, you need a terminal and a DC adapter. If you intend to test the Com Port, you will also need a PPT 4300 Loopback Plug. The IrDA Port tests require a JetEYE serial-to-IrDA adapter. To use the Diagnostic Test Utilities: 1. Remove the plug from the PCMCIA Slot and insert the PPT 4300 Utilities PC card. Insert the Loopback Plug and JetEYE serial-to-IrDA adapter. Plug in an external keyboard, if one is available. 2. Power the terminal from a DC Adapter to avoid interruptions that could be caused by a low battery or by having the terminal enter Doze or Sleep mode. 3. Boot the terminal from the card. When the Utilities Card Main appears, press 2 to display the AirWire Systems Test/Burn-in Menu (shown in Figure 11-3). 4. Select a number to run a particular test (described below), or press A to select All of the above. This option causes all of the tests to run in sequence except for the Battery Tests option. The Battery Tests must be performed separately. If the terminal fails a test, the diagnostics provide error and warning messages. Start the tests and follow the prompts, noting any errors. Some tests require input from you. If you find an error, re-run the test to generate an error log and report of the test results. Then press a V from the AirWire Systems Test/Burn-in menu to view the error log files. When you exit the Test/Burn-in menu, the system checks for the existence of the log files and prompts you to delete them or not. To end a test at any time, press <Esc>.
11-6
Page 221
Diagnostic Tests
5. Take action according to the results of the diagnostics tests. Then remove the PPT 4300 Utilities PC card and reboot normally. AirWire System Test/Burn-in Menu
1) System Board Test 2) Memory Test 3) Comm Port Test 4) IrDA Port Test 5) Video Tests 6) Keyboard Test 7) Keyboard Backlight Test 8) Battery Tests 9) Radio Tests A) All of the above V) View Error Logs E) Exit Choose a menu item... [1,2,3,4,5,6,7,8,9,A,V,E]?_
Figure 11-3. Diagnostic Tests Menu
Summary of Diagnostic Utilities This section summarizes the options on the Diagnostic Tests Menu on the PPT 4300 Utilities PC card. See Appendix D, Software Files, for detailed information on the diagnostic files and their parameters.
System Board Test This test uses cksys.exe to test the terminal’s main board. If the terminal fails the System Board Test, make sure that the date and time have been set correctly on the System tab of the Control Panel. Then try the test again. For any other problem, note the error message, and contact Symbol Technical Support.
Memory Test This test uses ckmem.exe to check the on-board RAM. If it fails the test, note the error message, and contact Symbol Technical Support.
11-7
Page 222
PPT 4300 Series Product Reference Guide
COM Port Test Before you perform this test, make sure the Loopback Plug has been securely placed into the Serial Port; the test will fail if a Loopback Plug has not been placed. Watch the test as it steps through each baud rate. Make sure characters are being sent and received. If there are problems with any baud rates, or characters are not being sent and received, note error messages and contact Symbol Technical Support. The COM Port Test uses ckcom.exe.
IrDA Port Test This tests the IrDA port using the ckirda.com utility. It requires a serial port adapter and a JetEYE serial-to-IrDA adapter, and it assumes the serial port is working. Plug the serial port adapter into the serial port. Attach the JetEYE adapter to the serial adapter (the test will fail if this adapter has not been attached). Aim the JetEYE at the PPT 4300’s IrDA port, at a distance of about 12 inches. Then press Y to start the test. When the test begins, make sure that characters are being transmitted and received. There should be 0 bytes in error and 0 bytes lost. See page D-18 for test parameters.
Video Controller Tests If you select All of the above from the AirWire System Test/Burn-in Menu, all of the AirWire System Video Tests run except for the Comprehensive Video Test (described on page 11-8). However if you select 5 from the AirWire System Test/Burn-in Menu, a sub-menu appears, as shown in Figure 11-4. You can select individual video tests from the Video Tests menu. If there are particular problems, document them, and contact Symbol Technical Support. AirWire System Video Tests
1) Video Controller Test 2) Comprehensive Video Test 3) CCFT Brightness Test 4) LCD Contrast Test 5) Digitizer Panel Test E) Exit Choose a menu item... [1,2,3,4,5,E]?_
Figure 11-4. Video Tests Menu 11-8
Page 223
Diagnostic Tests
Video Controller Test: This option tests for display functionality and quality. Watch the tests as they progress and note any display problems or idiosyncrasies (pixel dropout, odd screen artifacts). Comprehensive Video Test: This option performs a more comprehensive set of Video tests than option 1, including a test of video and text modes, and a display quality test. CCFT Brightness Test: This option tests the screen brightness. There should be three clearly distinguishable Brightness levels. You can adjust the Brightness level at the Display tab of the Control Panel. LCD Contrast Test: This option tests screen contrast. Contrast should go from very bright to very dark. The Digitizer Panel Test option tests the digitizer. Draw a large ‘X’ when asked to draw on the screen. Exit: Returns to the Diagnostic Tests Menu.
Keyboard Tests This option tests the keypad and external keyboard (if you have attached one). The tests run one after another, in sequence. Contact Symbol Technical Support if the terminal fails any of these tests: Key Press Test: Press all of the keys. Make sure all of the keys register when they are pressed. Also press a few external keyboard keys. To exit the test, press any key three times in succession. Auto-Repeat Test: On the auto-repeat test screen, press and hold a key until the matching key on the screen turns from yellow to blue. Lock Lights Test: After the auto-repeat test, the Lock Lights should be flashing for the Caps Lock, Num Lock and Scroll Lock keys. End of Keyboard Tests: At the end of keyboard testing, the terminal beeps twice (because you exited the key-pressing test before it finished).
Keyboard Backlight Test This test causes the Low Battery Light and the terminal’s keyboard backlight to flash on and off at one-second intervals. Press any key to end the test. The Display tab on the Control Panel has an option called Use brightness level 1 when keyboard backlight is turned on. If this option is selected, the screen will dim and brighten as the keyboard backlight goes on and off. If the Key Click option is enabled, you will hear the key click sound during this test.
11-9
Page 224
PPT 4300 Series Product Reference Guide
Note: The terminal must run on battery power to perform the following battery tests. If you have been powering the terminal from a DC Adapter, the diagnostics will pause. To continue, insert a Smart Battery into the terminal. Then unplug the DC Adapter from the DC Power port on the terminal. The display should continue to show clearly.
Smart Battery Test This option displays the Battery Pack Diagnostic Utility. You must run the terminal from a battery in order to perform this test. This screen displays a list of values related to the Battery Pack. Instructions: 1. The status of each value should be “Ok”. Older Utility Cards may show a value of “Error” for the Battery Capacity test. You can safely disregard this. Reasonable battery ranges with DC adapter removed: Main battery: 12v - 14v. Swap batteries: 3.0v - 4.5v. 2. Press the Battery icon. The pop-up Battery window should appear, showing current battery capacity. 3. Test the Low Battery Light and Swap feature. First, remove the battery and wait 5 seconds. The screen should go dark and the Low Battery light should flash. Then snap the battery back into place. The terminal should resume operation without turning itself off or rebooting. The Low Battery light should stop flashing.
Radio Tests This option displays a sub-menu as shown in Figure 11-5 on page 11-11. Signal Strength Test: This test provides detailed radio status and Spectrum24 version information. If the radio is operating correctly, and you are within about 20 feet of an Access Point in direct line of sight, this test should result in an RSSI reading of more than 40. The RSSI parameter provides a relative indication of signal strength. If no value appears, the radio is not communicating with the Access Point. Press <Esc> to return to the Radio Tests menu. Refer to Spectrum24 documentation for more information about s_info.exe. Ping Test: The Ping Test should run 50 times with no errors. Press <Esc> to exit to the Radio Tests menu.
11-10
Page 225
Diagnostic Tests
AirWire System Radio Tests
1) Signal Strength Test (s_info.exe) 2) Ping Test 3) Help Menu S) Set IP Address N) Set Net ID E) Exit Choose a menu item... [1,2,3,S,N,E]?_
Figure 11-5. Radio Test Menu Set IP Address: If you need to ping a different Access Point or Host, use this option to set the IP address that gets pinged during the Ping Test (option 2). To do this, type S to select Set IP Address. This opens the Ping Test utility in the NED editor. Follow the instructions in the file to locate and set the IP Address. Save the file and exit NED. Set Net ID: Use this option to change the Network ID. This is necessary if you are testing several different Access Points with different IDs. To change the Net ID: 1. Press N to select the option from the Radio Test menu. 2. Locate the line net_id 1XX and change the ID to the correct one. 3. Save the file, then exit. 4. Exit the menus until you are at the DOS prompt. 5. Reboot the terminal. You must reboot the terminal or the new ID will not be applied.
11-11
Page 226
PPT 4300 Series Product Reference Guide
11-12