Changing the Battery Note:
For the first two to three days on a new terminal, end your session and turn the terminal off before you attempt to change the battery. This gives the swap battery time to fully charge.
You can change the battery on a PPT 43xx terminal without logging out or losing your session. To do this: 1. Make sure you have a fully charged battery available and close at hand. 2. Turn the terminal display-side down, but do not rest it on a table. The table may cause keys to be pressed, causing input to an application. 3. Push up on the Battery Latch. The Ejector Spring pushes the battery up.
Battery Latch 4. Slide the discharged battery out of the compartment. When you remove the battery, the terminal automatically goes into Sleep mode. A swap battery inside the terminal
Quick Reference
Page 20
qrgfinal.fm Page 20 Thursday, January 8, 1998 3:42 PM
20 supplies power and maintains your session for 15-30 seconds. Note:
You may find it easier to remove the battery if you hold the terminal with the display facing you, and the back of the terminal in your hand. Then, push up on the Battery Latch, and allow the battery to slip out of the battery compartment.
5. Place the bottom of a fully charged battery pack into the battery well. The tabs at the bottom of the battery fit into two slots at the bottom of the battery well. 6. Gently push the top into place until the Battery Latch clicks into place and holds the battery.
Battery Latch Ejector Spring
Battery Well
Quick Reference
Battery Contacts
Page 21
qrgfinal.fm Page 21 Thursday, January 8, 1998 3:42 PM
21
Re-charging a Battery Pack Before you use a PPT 43xx terminal, make sure its NiMH battery pack has been completely charged. As an option, Symbol supplies a Battery Charger that can charge up to four batteries at once. To re-charge a battery: 1. Make sure the charger is attached to a power supply. The green Power LED should be on. 2. Insert a battery into the battery charger as shown below. Each slot has two pins on one side, and one pin on the other. Place the side of the battery with two contacts into the 2-pin side of the slot. Never force a battery into the charger; batteries should slide in easily. Note:
If you have just removed a battery from the charger, wait 10 - 15 seconds while the charger resets itself before inserting another battery into the same slot.
Quick Reference
Page 22
qrgfinal.fm Page 22 Thursday, January 8, 1998 3:42 PM
22
3. If you have inserted the battery correctly, the Yellow CHARGING LED comes on in the panel beside the battery slot to indicate that a battery is charging. 4. If the LED does not come on, take the battery out and then re-insert it, making sure that you are inserting it correctly. 5. A flashing green READY light appears when the battery is charged. Batteries recharge to full capacity within three hours.
Conditioning New Batteries New batteries need to be conditioned before you use them. Conditioning ensures that a new battery can carry a full charge. To condition a new battery, insert it into the battery charger and press the Condition button on the panel beside the battery slot. The conditioning cycle takes three to six hours, and the READY light appears when conditioning is complete. To extend battery life, repeat the conditioning cycle approximately once every two months.
Battery Rejection If the red REJECTED indicator flashes, the battery is faulty or damaged. Remove it from the battery charger and dispose of it properly. If the battery is still within its warranty period, contact your local Symbol Representative or the Symbol Support Center for replacement information.
Quick Reference
Page 23
qrgfinal.fm Page 23 Thursday, January 8, 1998 3:42 PM
23
Using an External Power Source You can connect the PPT 43xx to a DC adapter so that it can be powered from a standard electrical outlet. Note that the Power Management features are disabled when the terminal is running from the DC adapter. To connect power: 1. Connect the DC Adapter plug into the DC Power Input on the right side of the terminal. Note:
Plug the other end of the Adapter into the electrical outlet. Use only a Symbol-approved DC adapter.
Quick Reference
Page 24
qrgfinal.fm Page 24 Thursday, January 8, 1998 3:42 PM
24
Understanding the Power Save Modes When the terminal is not in active use, it can use Power Save Modes to decrease the drain on the battery. Note that your facility may deactivate some modes. Power Save Modes include: Mode
Description
Normal
The terminal is in full active use, with all components working at full power. After 17 - 76 seconds of inactivity (no input from keyboard or pen), the terminal enters Doze mode. Use the Control Panel to configure the amount of time before the terminal enters Doze mode.
Doze
In Doze mode, the session freezes and the screen dims. The session resumes and the screen returns to normal when you use the keyboard or pen.The terminal stays in Doze mode for 4 seconds to 17 minutes, depending on the Control Panel setting. Then it enters Sleep mode. If the host disconnects from your session while the terminal is in Doze mode, you must log in again.
Sleep
In Sleep mode, the session freezes and the screen display turns off. The screen returns to normal when you use the keyboard or pen. The terminal stays in Sleep mode for 1 to 272 minutes, depending on the Control Panel setting. The host may disconnect from your session when the terminal is Sleeping. If this happens, you must log in again. Note: If the battery is removed or falls to critically low levels (<1%), the terminal places itself into Sleep mode for up to 60 seconds, and then switches off.
Quick Reference
Page 25
qrgfinal.fm Page 25 Thursday, January 8, 1998 3:42 PM
25
Mode Off
Description After 1 to 272 minutes in Sleep mode, the terminal switches off. To reboot the terminal, press the Power icon. If you have not saved your work, you may lose it when the terminal turns off.
Quick Reference
Page 26
qrgfinal.fm Page 26 Thursday, January 8, 1998 3:42 PM
26
Service Information Before you use a terminal, it must be configured to operate in your facility’s network and run your applications. If you have a problem with running your terminal or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center:
1-800-653-5350 Outside North America, contact your local Symbol representative.
Note:
Before returning the PPT 4300, you must complete the Return Equipment Checklist form, which you will find in the back of your PPT 4300 Product Reference Guide, p/n 70-31471-01. If you cannot find this form, you can also request one from the Symbol Support Center, at the phone number listed above. This checklist is a federally mandated Occupational Safety and Health Adminstration (OSHA) form, which must be completed when returning equipment which may have come in contact with bloodborne pathogens.
Symbol products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at Symbol’s option, with reasonable promptness after being returned to Symbol by a carrier selected and paid for by the customer. These provisions do not prolong the original warranty term for any product which has been repaired or replaced by Symbol. This warranty applies to the original owner and does not extend to any product which has been subject to misuse, neglect, accidental damage, unauthorized repair or tampering. Preventive maintenance activities are not covered by warranty.
Quick Reference
Page 27
qrgfinal.fm Page 28 Thursday, January 8, 1998 3:42 PM
70-31470-01 Revision A, December 1997