Page 1
qrgfinal.fm Page 1 Thursday, January 8, 1998 3:42 PM
RS 2200/3200 Series PPT 4300 Series r we
Po
+
=
Quick Reference
Page 2
qrgfinal.fm Page 2 Thursday, January 8, 1998 3:42 PM
1997 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 WWW: http://www.symbol.com
Quick Reference
Page 3
qrgfinal.fm Page 3 Thursday, January 8, 1998 3:42 PM
3
Radio Frequency Interference Information Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations. • Cet appareil numérique de la Classe A respecte toutes les exigences du Reglement sur le Materiél Brouilleur du Canada.
General Information 1) The terminal must be powered by a power supply that meets SELV and limited power source limits in accordance with EN60950. Das gerät muß mit einen Netzteil betrieben werden das eine SELV Spannung und eine Spannung nach 2.11 EN60950 abgibt. 2) The terminal is not a workstation and has not been evaluated to the ergonomic standard. Das gerät ist keine Bildschirmarbeits platz und erfüllt nicht die Andforderungen der Ergonomic.
Radio Frequency Interference Requirements - Canada This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe A respecte toutes les exigences du Reglement sur le Materiél Brouilleur du Canada.
RF Devices Symbol’s RF products are designed to be compliant with the rules and regulations in the locations into which they are sold and will be labeled as required. The majority of Symbol’s RF devices are type approved and do not require the user to obtain license or authorization before using the equipment. Any changes or modifications to Symbol Technologies equipment not expressly approved by Symbol Technologies could void the user’s authority to operate the equipment.
Quick Reference
Page 4
qrgfinal.fm Page 4 Thursday, January 8, 1998 3:42 PM
4
Introduction The PPT 4300 is a hand-held, PC-compatible terminal that incorporates pen input and a QWERTY keyboard. The PPT 4340 model also uses radio frequency technology to allow wireless communication with an existing network. Throughout this Quick Reference, “PPT 43xx” refers to any 4300 Series terminal.
About This Guide This guide presents basic information on using the PPT 43xx terminal. It describes how to: • Starting the Terminal • Starting Applications • Using the Touch Screen • Using the Keypad • The Direct Access Panel • Providing Power to the Terminal • Re-charging a Battery Pack Note: Before you start a PPT 43xx terminal, make sure the Run/Ship switch has been set to the Run position. See Parts of the PPT 43xx on page 5 for the exact location of the Run/Ship switch.
Quick Reference
Page 5
qrgfinal.fm Page 5 Thursday, January 8, 1998 3:42 PM
5
Parts of the PPT 43xx The diagrams on this page show the parts of the PPT 43xx. 1
2 6
4 11 5 +
=
3
10 9 8 12
7
20
14 23
21
15 13
18
22
13
17 16 19
Quick Reference
Page 6
qrgfinal.fm Page 6 Thursday, January 8, 1998 3:42 PM
6
Parts of the PPT 43xx (cont’d) 1. Pen Holder 2. Pen 3. Direct Access Panel 4. Display Screen 5. Keypad 6. Antenna 7. IrDA Port 8. Force On Switch 9. DC Power Input 10. External 3.3v Keyboard Connector 11. RS232/TTL Interface Connector 12. PCMCIA slot 13. Rubber Foot 14. Support for RS232/TTL Interface plug 15. Battery Latch 16. Battery Well 17. Run/Ship Switch 18. NiMH Battery Pack 19. Battery Ejector 20. Regulatory Label 21. Serial Number Label 22. Battery Pack Contacts 23. Strap Mounting Boss
Quick Reference
Page 7
qrgfinal.fm Page 7 Thursday, January 8, 1998 3:42 PM
7
Using the Power Icon The Power icon is the top icon on the Direct Access Panel on the left side of the display. To select it, press it with the pen. If the terminal is On: the Power icon places the terminal into Sleep mode (see Understanding the Power Save Modes on page 24). After a time in Sleep mode, the terminal shuts off. If the terminal is in Sleep mode: the Power icon re-activates the session that was active when the terminal went to Sleep. Tapping the screen or a keypad key also activates the terminal. If the terminal is Off: the Power icon starts the terminal.
Starting the Terminal To start the terminal, press the Power icon with the pen. Hold the pen down until the terminal beeps and begins to boot (about one second). If the terminal does not boot, check to make sure you have a charged battery, inserted correctly, and that the Run/Ship switch in the Battery Well is set to “Run”. To force a terminal to re-boot, press the <Ctrl-Alt-Del> keys, or press the Force On switch in the IrDA port (see Parts of the PPT 43xx on page 5).
Starting Applications After the terminal boots, one of the following appears: • a WINFRAME window, • a Terminal Emulator Host Choice List (shown on page 8), or • a custom application, specific to your facility. Follow your facility’s procedures for logging in.
Quick Reference
Page 8
qrgfinal.fm Page 8 Thursday, January 8, 1998 3:42 PM
8
Host Choice List Display Application/Host Name Host IP Address 1. ubiserver 192.75.16.1 2. zephyr 192.75.16.8 3. Library of Congress 140.147.254.3
Mode VT220 VT220 IBM3270
Key Map standard standard 3270 custom
Directions:• Press the number or letter associated with the host, • use arrow keys to highlight the host and press <Enter>, • tap the host with the pen, or • press <Esc> to quit.
A Terminal Emulator Host Choice Screen
Turning the Terminal Off Usually a terminal turns off when you end a session and log out. For details, see the table below. If you do not log out, and the terminal goes into Sleep mode, it turns itself off after a certain amount of time (see Understanding the Power Save Modes on page 24). Depending on how the host computer is set up, your session may or may not terminate, if you do not log out before the terminal goes to Sleep. Session Type
How to Exit
Terminal Emulation
Follow your facility’s procedures or press <Shift-Alt-X> to close a session. When all sessions are closed, press <Esc> to exit the Choice List and turn off the terminal.
Citrix WINFRAME
Logoff from the WINFRAME Windows session. Then select the Exit button on the WINFRAME DOS window.
Quick Reference
Page 9
qrgfinal.fm Page 9 Thursday, January 8, 1998 3:42 PM
9
Session Type
How to Exit
DOS
Type ‘off’ and press <Enter>.
Using the Terminal Using the Touch Screen The PPT 43xx is designed to be used with a pen stylus. The pen acts as a mouse. The table below describes how the pen works in a windows session run on the terminal’s Citrix® WINFRAME™ client. If you are running a terminal emulator or DOS application, the pen may be disabled, or may behave differently, depending on the application and the host configuration. To:
Do This:
Move the pointer/ cursor
Place the end of the pen onto the surface of the display. The arrow or cursor goes to where the pen is located.
Left click
Tap once with the pen. Do not tap too hard on the display.
Double click
Tap twice, quickly, with the pen.
Right click
Select the Mouse icon to turn the next pen tap into a right click. After a single or double right click, the pen tap automatically reverts to acting as a left mouse click.
Drag objects (Drag & Drop)
Place the pointer on the object that you wish to move (e.g., on the Title Bar of a window). Without lifting the pen from the display, drag the tip of the pen to the new location for the object. Lift the pen to drop the object.
Note:
If you lose your pen, DO NOT use anything that will scratch or mark the screen. Symbol can supply extra