The text of a manual · part 1 of 2
PL 370/470 RF Cradle Quick Reference, pages 1 to 8
Pages 1 to 8 of 16
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PL370 and Symbol PL470
Page 1
L 370/47 «0 R F Cc radiitie
Page 2
P L
3 7 0 / 4 7 0
R F
C r a d l e
1999-2002 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol is a registered trademark of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894; 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647; 6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213; 6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; 6,380,949; 6,394,355; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187, NI-068564 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713 rev. 06/02
Page 3
Q u i c k
R e f e r e n c e
Introduction The PL 370/470 RF cradle acts as a stand, host communication interface, and a charger for the Phaser RF scanner. It can sit on a desktop or be wall-mounted - whichever is more convenient. The cradle receives data from the scanner via radio frequency (RF) transmissions through the antenna, then transmits that data to the host device through an attached cable. The cradle also charges the scanner’s battery pack (in the scanner). There are two versions of the cradle: • •
PL 470 Cradle: radio retail version PL 370 Cradle: radio industrial version.
This Quick Reference Guide provides basic instruction on the set up and use of the cradle. Unless otherwise noted, the term PhaserLink refers to all versions of the cradle.
Equipment Supplied The following equipment is supplied with your cradle: • Two screws (for wall mounting, see page 11) • One velcro strip (for desk mounting) • Four rubber feet (for desk mounting) • Cradle. Save the shipping container for storing or shipping. Inspect all your equipment for damage. If anything is damaged or missing, call your authorized Customer Support Representative immediately.
Related Documentation P 370/470 RF Scanner Product Reference Guide, p/n 72-38495-xx P 370/470 RF Scanner Quick Reference Guide, p/n 72-38493-xx
1
Page 4
P L
3 7 0 / 4 7 0
R F
C r a d l e
Parts of the Cradle Antenna
Pairing Label Scanner Support Tab
Charging/Communications Contacts
Charging LED
COM 1 Port
Power Port
Wall-mounting Socket 1
Wallmounting Socket 2
2
Page 5
Q u i c k
R e f e r e n c e
Connecting to the Host To connect the cradle to a host: COM1
1. Insert the appropriate interface cable from the host computer into the COM1 port. 2. Connect the power connector of the power supply (p/n 50-19000-101) into the cradle’s power port (the cradle cannot be powered by the host computer).
Power Port
3. Connect the appropriate line cord to the power supply and the other end to an AC power source.
Wall Mounting Before wall-mounting the cradle, the scanner support tab must be changed from the desk-mount position to the wall-mount position. 1. Lift the scanner support tab out of the top part of the cradle and replace it in the wall-mount position.
Desk Mount
3
Wall Mount
Page 6
P L
3 7 0 / 4 7 0
R F
C r a d l e
2. Seat the cables from the bottom of the cradle in the grooves along the length of it so that the bottom of the cradle is smooth. 3. Fasten the two screws provided into the wall where the cradle will hang, leaving about 1/8” (0.3 cm) of the screw outside the wall for the cradle’s wall mounting sockets (A template is provided for you on page 11).
Cable Grooves
4. Place the cradle over the screw heads and slide down until it fits into place. Slight pressure upwards should not move the cradle. 5. Position the antenna vertically (pointing toward the ceiling). 6. Place the scanner in the cradle.
Inserting Phaser in the Cradle Place the scanner in the cradle so that the top of the scanner sits in the larger part of the cradle and the metal contacts on the bottom of the scanner touch the contacts on the cradle.
Pairing The wireless “connection” between the scanner and cradle is the low power radio transmission through RF transceivers in both the scanner and cradle. Communication consists of bidirectional message packets.
4
Page 7
Q u i c k
R e f e r e n c e
However, the scanner and cradle must be paired for this communication to work. Note:
After a new host is installed at the cradle, re-scan the pairing bar code. This allows the cradle to notify the scanner of the change in the host device.
To pair the scanner with the cradle: 1. Scan the pairing bar code on the top of the cradle. A duplicate pairing bar code is located in the well on the bottom of the cradle. 2. Insert the scanner into the cradle (recommended but not required). Note that you cannot scan data until this linking is complete. 3. At that time there is an exchange of information between the scanner and the cradle. This occurs in a few seconds if the scanner is in the cradle or over a minute if not in the cradle. 4. After the exchange is complete, the scanner and cradle are paired. Successful pairing is indicated by as warble beep; failure, or unsuccessful link, is indicated by a Lo Hi beep.
Sending Data to Host Computer The cradle receives data from the scanner and transmits it to the host computer via the interface cable.
Recharging the Battery in the Scanner To charge the scanner’s battery, place the scanner in the cradle, ensuring the metal contacts on the bottom of the scanner touch the contacts on the cradle. A complete charge takes up to 4 hours, depending upon the remaining charge in the battery.
5
Page 8
P L
3 7 0 / 4 7 0
R F
C r a d l e
Charging LED Once the scanner is placed in the cradle, it waits 15 minutes to start charging the battery in the scanner. The LED indicates the charging status as follows: Off
Scanner is not in cradle
Slow Blink
Scanner is in cradle, not charging
Fast Blink
Scanner is in cradle, charging
On
Scanner is in cradle, charge cycle is complete
Troubleshooting If the cradle does not work after you’ve followed these operating instructions: • • •
Check the system power. Check for loose cable connections. Check that the scanner is sitting properly in the cradle.
Cleaning Wipe the cradle periodically with a lens tissue or other material suitable for cleaning optical material, such as eyeglasses. Caution:
Do not pour, spray or spill any liquid on the cradle.
6