Page 1 read from a scan by OCR; it may hold reading errors

pooans ounnn ka yore

2)

09 v / 0 9

1

Page 2

P L

3 6 0 / 4 6 0

C r a d l e

© 2001 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172, D418,500; D419,548; D423,468; D424,035 D431,158; D430,159; D431,562. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 09/00

Page 3

Q u i c k

R e f e r e n c e

The PhaserLink PL 360/460 Cradle acts as a stand, host communication interface, and a charger for the Phaser Scanner. It can sit on a desktop or be wall-mounted - whichever is more convenient. The cradle receives data from the scanner via connectors in the bottom of the scanner and the top of the cradle. It then transmits that data to the host device through an attached cable. The cradle also provides power for charging the scanner’s battery pack (in the scanner). The cradle has a charge status indicator light. There are two versions of the cradle available: • PL 460 Cradle: the batch retail version • PL 360 Cradle: the batch industrial version This Quick Reference Guide provides basic instruction on the set up and use of the cradle. Unless otherwise noted, the term PhaserLink refers to all versions of the cradle.

Equipment Supplied The equipment supplied is: • • • • •

Two Screws (for wall mounting) One Velcro Strip (for desk mounting) Four Rubber Feet (for desk mounting) This Guide Cradle

Save the shipping container for storing or shipping. Inspect all your equipment for damage. If anything is damaged or missing, call your authorized Customer Support Representative immediately.

Related Documentation Phaser Series Scanner Product Reference Guide, p/n 70-33629-xx P 360/460 Memory Scanner Quick Reference Guide, p/n 70-33628-xx 1

Page 4

P L

3 6 0 / 4 6 0

C r a d l e

Parts of the Cradle This figure shows the parts of the PhaserLink Cradle:

Scanner Support Tab

Charging/ Communications Contacts

Charging LED Indicator

COM 1

Power Port

COM 2

Wallmounting Socket 1

Wallmounting Socket 2

2

Page 5

Q u i c k

R e f e r e n c e

Connecting To The Host On the bottom of the cradle are three ports -

COM 1 COM 2

Power Port

COM 1 connects to the host computer, COM 2 is used for daisychaining multiple cradles together, and the Power Port supplies power to the cradle. 1. Insert the independent power plug into the Power Port (the cradle cannot be powered by the host computer).

3

Page 6

P L

3 6 0 / 4 6 0

C r a d l e

2. Insert the cable from the host computer into COM 1 and the cable to the other cradles, if any, into COM 2.

Daisy-Chaining Note: The cradle supports daisy-chaining when connected to a serial host and not when using Synapse interfaces. To daisy-chain two or more cradles together, connect COM 1 of the first cradle to the host and COM 2 to COM 1 of the second cradle. Then connect COM 2 of the second cradle to COM 1 of the third cradle. You can daisy-chain up to 12 cradles to one host in this manner.

Wall Mounting Before wall-mounting the cradle, the scanner support tab must be changed from the desk-mount position to the wall-mount position. 1. Lift the scanner support tab out of the top part of the cradle and replace it in the wall-mount position, as shown:

Desk Mount

Wall Mount

4

Page 7

Q u i c k

R e f e r e n c e

2. Seat the cables from the bottom of the cradle in the grooves along the length of it so that the bottom of the cradle is smooth and flat, as shown:

3. Secure two screws (included) to the wall. A template is provided for you on page 11.

4. Fasten the screws into the wall where the cradle will hang, leaving about 1/8” (.3 cm) of the screw outside the wall so that the cradle will have something to hang on. 5. Place the cradle over the screw heads and slide down until it fits into place. Slight pressure upwards should not move the cradle. 6. Place the Phaser in the cradle. 5

Page 8

P L

3 6 0 / 4 6 0

C r a d l e

Inserting Phaser in the Cradle Place the Phaser scanner in the cradle so that the top of the scanner sits in the larger part of the cradle and the metal contacts on the bottom of the scanner touch the contacts on the cradle, like so:

Sending Data to Host Computer To set up the PhaserLink Cradle for communications between a Phaser and a host computer: 1. Connect the cradle to the host computer as described in Connecting To The Host on page 3. 2. Insert the Phaser in the cradle. 3. Start the communications program on the host computer and the Phaser.

Recharging the Battery in the Phaser 1. Connect the cradle to a receptacle supplying AC power of the proper voltage level. 2. Place the scanner in the cradle, ensuring the metal contacts on the bottom of the scanner touch the contacts on the cradle. 3. A complete charge takes up to 4 hours, depending upon the remaining charge in the battery of the scanner.