What is in it
Symbol's quick reference guide for the PDT 8000 Series mobile terminal, covering the batch and Spectrum24 versions in 64MB and 128MB RAM configurations. It lists accessories and the parts of the terminal, then explains compact flash cards, installing and charging batteries, starting and aligning the screen, the backlight, keyboard, stylus and input methods, scanning, soft and hard resets, host communications, LED indicators, maintenance and troubleshooting, with battery and regulatory information.
Its parts
- Introduction
- Accessories
- Parts of the Terminal
- Inserting a Compact Flash Storage Card
- Installing Batteries
- Charging the Battery
- Starting the Terminal
- Using the Keyboard
- Input Methods
- Scanning with the Terminal
- Resetting Your Terminal
- Host Communications
- LED Indicators
- Maintaining the Terminal
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
The Symbol PDT 8000 Series Quick Reference for the batch and Spectrum24 versions of the terminal (the PDT 8000 and the PDT 8046). It walks through the parts, accessories, batteries and charging, start-up, the keyboard, scanning, resets, host communication and printing, LED indicators, care and troubleshooting.
- Device
- Microsoft Windows Pocket PC 2002 terminal with 1-dimensional bar code scanning p. 3
- Display
- 3.9 inch 1/4 VGA color LCD with touch screen p. 3
- Memory
- 64MB RAM (p/n PDT80XX-TS26XXX) or 128MB RAM (p/n PDT80XX-TS28XXX) configurations p. 3
- Battery
- 7.4 volt 1130 mAh prismatic lithium-ion, p/n 21-54882-01 p. 4
- Communications
- Serial port and IrDA port; USB client on 128MB RAM configurations only; PDT 8046: Spectrum24 wireless LAN p. 3, 22
- Keypad
- Numeric keypad (0-9) with color-coded Shift functions p. 13
- Power supply
- Symbol-approved power supply 50-14001-005, output 15VDC, minimum 2.5A p. 37
- Charging
- First charge about four hours with the Serial Charging Cable; memory backup battery up to 20 hours at first use p. 9
- Cables
- Serial Charging Cable 25-55853-01; USB Cable 25-59272-01; Power Supply with cables CBL-8000-100U; Snap-On Autocharger VCA8000-01; Snap-On DEX cable CBL-8000-100-DEX; Snap-On Printer cable CBL-8000-100-INT1 p. 4
- Cradles
- Single-Slot Serial CRD8000-1000S; Single-Slot Modem CRD8000-1000M; Four-Slot Charging CHS8000-4000C, CHS8000-4000B; Four-Slot USB-to-Ethernet CRD8000-4000E p. 4
- Other accessories
- Stylus 11-55475-05; holster 11-57530-02; Snap-On Modem Module MDM8000-xxx; UBC Adaptor 21-32665-33 for spare batteries p. 4, 10
- Storage card
- Compact flash card slot behind a screw-on door on top p. 7
- Indicators
- Charge LED: slow blinking amber charging, fast blinking amber charging error, solid amber done; scan LED: red scanning, green good decode p. 24
- Auto power-off
- Settable from one to five minutes, in one-minute steps p. 27
What this manual walks you through
- Inserting and removing a compact flash card p. 7
- Installing the battery p. 8
- Charging the main, backup and spare batteries p. 9, 10
- Starting the terminal and aligning the screen p. 11, 12
- Adjusting the backlight p. 12
- Using the keyboard keys p. 13, 14, 15
- Scanning bar codes p. 21
- Performing a soft or hard reset p. 21, 22
- Printing through the snap-on printer cable or an IrDA printer p. 23
- Troubleshooting power, charging, communication, memory and scanning problems p. 26, 27, 28, 29
Good to know
- Do not expose the battery to more than 140°F (60°C), and do not take it apart, burn it or short it. p. 8
- Do not remove the main battery until the backup battery is fully charged, which can take up to 20 hours, or data may be lost. p. 9
- A hard reset erases all records and entries in RAM and restores factory default settings; try a soft reset first. p. 22
- Do not soft reset a suspended terminal; press Power to wake it first. p. 21
- For IrDA printing, aim the IrDA port at the printer from at most 39 inches, and the terminal needs software set up for that printer. p. 23
Questions this manual answers
What battery does the Symbol PDT 8000 take?
One 7.4 volt 1130 mAh prismatic lithium-ion battery; the additional battery is p/n 21-54882-01. p. 4
How do I hard reset a PDT 8000?
Remove the battery door, press and release Power Key + Scan Button, then replace the door. It erases all records and entries in RAM. p. 22
What power supply does the PDT 8000 use?
Only a Symbol-approved power supply 50-14001-005, rated 15VDC output and at least 2.5A. p. 37
Does the PDT 8000 have USB?
The USB client is available only on the 128MB RAM configurations. p. 3
What does a fast blinking amber charge LED mean on the PDT 8000?
It signals an error in charging; slow blinking amber means charging and solid amber means charging is complete. p. 24
Contents
Chapters and sections
Each line opens the PDF at its page.
- Introduction3
- About This Guide3
- Accessories4
- Parts of the Terminal5
- Parts of the Terminal (continued)6
- Inserting a Compact Flash Storage Card7
- Removing a Compact Flash Storage Card7
- Installing Batteries8
- Charging the Battery9
- Starting the Terminal11
- Adjusting the Backlight12
- Using a Headset13
- Using the Keyboard13
- Using the Stylus15
- Today Screen16
- Navigation Bar and Command Bar17
- Input Methods18
- Scanning with the Terminal21
- Resetting Your Terminal21
- Host Communications22
- LED Indicators24
- Maintaining the Terminal25
- Troubleshooting26
- END-USER LICENSE AGREEMENT30
- Battery Information33
- Ergonomic Recommendations33
- Regulatory Information34
2 more lines, from page 39 on
The whole text · 5 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file