The text of a manual · part 34 of 41
PDT 8000 Series Product Reference Guide: Chapter 13 Maintenance and Troubleshooting
Pages 285 to 292 of 352, from PDT 8000 Series Product Reference Guide
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PDT-8037, Symbol PDT-8046, Symbol PDT-8056 and Symbol PDT-8000
Page 285
Chapter 13 Maintenance and Troubleshooting Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3 Maintaining the Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-4
13-1
Page 286
PDT 8000 Series Product Reference Guide
13-2
Page 287
Maintenance and Troubleshooting
Introduction This chapter includes instructions on cleaning and storing your terminal, and provides troubleshooting solutions for potential problems during terminal operation.
Maintaining the Terminal For trouble-free service, observe the following tips when using the terminal: •
Take care not to scratch the screen of the terminal. When working with the terminal, use the supplied stylus or plastic-tipped pens intended for use with a touchsensitive screen. Never use an actual pen or pencil or other sharp object on the surface of the terminal screen.
•
Although the terminal is water and dust resistant, do not expose it to rain or moisture for an extended period of time. In general, treat the terminal as you would a pocket calculator or other small electronic instrument.
•
The touch-sensitive screen of the terminal contains glass. Take care not to drop the terminal or subject it to strong impact.
•
Protect the terminal from temperature extremes. Do not leave it on the dashboard of a car on a hot day, and keep it away from heat sources.
•
Do not store or use the terminal in any location that is extremely dusty, damp or wet.
•
Use a soft lens cloth to clean the terminal. If the surface of the terminal screen becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution.
13-3
Page 288
PDT 8000 Series Product Reference Guide
Troubleshooting Table 13-1. Troubleshooting Your Terminal Problem
Cause
Solution
Terminal does not turn on.
Lithium-ion battery not charged.
Charge or replace the lithium-ion battery in the terminal.
Lithium-ion battery not installed properly.
Ensure battery is installed properly.
System crash.
Perform a soft reset. If the terminal still does not turn on, perform a hard reset. See Resetting Your Terminal on page 2-34.
Terminal does not respond Terminal is not Check wake-up configuration. See to wake-up source. configured to respond to Configuring Wake-ups on page 1-34. any wake-up source. Terminal battery door was reinstalled.
Press the Power button to turn on the terminal. The terminal only responds to the Power button after the battery door is reinstalled.
Battery fault condition.
Press the Power button to turn on the terminal. The terminal only responds to the Power button after a battery fault condition.
Terminal suspended due Press the Power button to turn on the to very low battery. terminal. The terminal only responds to the Power button after it goes into suspension mode due to very low battery. Note: Ensure battery is charged or replaced with a charged battery before powering on terminal again.
13-4
Page 289
Maintenance and Troubleshooting
Table 13-1. Troubleshooting Your Terminal (continued) Problem Rechargeable lithium-ion battery did not charge.
Cause Battery failed.
Solution Replace battery. If your terminal still does not operate, try a soft reset, then a hard reset; see Resetting Your Terminal on page 2-34.
Terminal removed from Insert terminal in cradle and begin charging. cradle while battery was The lithium-ion battery requires up to 4 charging. hours to recharge fully. Battery is not within charging temperature range.
Ensure the battery is within the charging temperature range. See Appendix D, Technical Specifications for specified range. Note: The terminal contains circuitry that monitors the battery temperature. This circuitry will disable battery charging if the battery temperature is not within the specified range.
Cannot see characters on display.
Terminal not powered on.
Press the Power button.
Fail to communicate with IrDA printer.
Distance from printer is not between 5 inches and 39 inches.
Bring the terminal closer to the printer and attempt communications again.
Obstruction interfered with communication.
Check the path to ensure no objects were in the way.
Application is not enabled to run IrDA printing.
Printer support must be included with the application to run IrDA printing on the terminal. See your System Administrator.
Terminal removed from cradle or unplugged from host PC during communications.
Replace the terminal in the cradle, or reattach the terminal to the host PC, and retransmit.
Incorrect cable configuration.
See your System Administrator.
During data communication, no data was transmitted, or transmitted data was incomplete.
Communication Perform setup as described in the Chapter software was incorrectly 4, Communications. installed or configured.
13-5
Page 290
PDT 8000 Series Product Reference Guide
Table 13-1. Troubleshooting Your Terminal (continued) Problem GPRS/GSM connection cannot be established.
Cause
Solution
SIM card is not installed. See Installing a SIM Card on page 1-24 for detailed instructions. Network is busy.
Try again after 5 minutes.
Poor signal/out of coverage.
Ensure that the area you are in is covered by your network provider. If you are receiving a poor signal, relocate to an area that provides better signal.
GPRS parameters are entered incorrectly.
See GPRS Parameters Configuration on page 10-3 for detailed parameter information.
Band is set incorrectly.
See Change Band Screen on page C-8 for correct band information.
No sound is audible.
Volume setting is low or turned off.
Check the System Volume slider in the Sounds & Reminders properties dialog box (under Start - Settings) to ensure the volume is not turned down or off.
Terminal turns itself off.
Terminal is inactive.
Your terminal turns off after a period of inactivity. If the terminal is running on battery power, this period can be set from 1 to 5 minutes, in one-minute intervals. If the terminal is running on external power, this period can be set to 1, 2, 5, 10, 15, and 30 minutes. Check the Power dialog box (in the System tab under Start - Settings), and change the setting if you need a longer delay before the automatic shutoff feature activates.
Battery is depleted.
Replace the battery.
Battery cover is removed.
Replace the battery door.
13-6
Page 291
Maintenance and Troubleshooting
Table 13-1. Troubleshooting Your Terminal (continued) Problem
Cause
Terminal doesn’t recognize Character strokes my handwriting. written incorrectly with the stylus.
Solution If you’re using the Block Recognizer input method, characters must be written a certain way. See Appendix A, Block Recognizer Characters for information about how to write character strokes.
Character strokes If you’re using the Block Recognizer or written on the wrong part Letter Recognizer input method, make the of the LCD screen. character strokes in the lower character entry area on the screen, not on the display part of the screen. Lowercase and uppercase letters, and numbers written on the wrong parts of the LCD screen.
Ensure you are writing letters and numbers in the appropriate section of the writing area.
Tapping the screen buttons LCD screen not aligned or icons does not activate correctly. the corresponding feature.
Align the screen. Tap Start - Settings System tab - Screen icon, or hold down the Shift key and press the 2 key.
The system is hung.
A message appears stating Too many files stored on that your terminal memory the terminal. is full. Too many applications installed on the terminal.
Beamed data does not transmit.
Soft reset the system. To perform a soft reset, see Resetting Your Terminal on page 2-34. Delete unused memos and records. You can save these records on your computer. If you have installed additional applications on your terminal, remove them to recover memory. Tap Start - Settings - System tab Remove Programs icon and select the unused program. Tap Remove.
Terminals too close Confirm that the terminals are at least 5 together or too far apart. inches and at most 39 inches apart. Also ensure that there is a clear path between the two devices. Insufficient room lighting.
Adjust the room lighting or move to a different location.
13-7
Page 292
PDT 8000 Series Product Reference Guide
Table 13-1. Troubleshooting Your Terminal (continued) Problem
Cause
Solution
When receiving beamed data an out of memory message appears.
Not enough free memory Your terminal requires at least twice the available for receiving amount of memory available as the data you data. are receiving. For example, if you are receiving a 30K application, you must have at least 60K free.
Your terminal does not accept scan input.
Scanning application is not loaded.
Verify that the unit is loaded with a scanning application. See your System Administrator.
Unreadable bar code.
Ensure the symbol is not defaced.
Distance between exit window and bar code is incorrect.
Ensure you are within proper scanning range.
Terminal is not programmed for the bar code.
Ensure the terminal is programmed to accept the type of bar code you are scanning.
Terminal is not programmed to generate a beep.
If you are expecting a beep on a good decode and don’t hear one, check that the application is set to generate a beep on good decode.
Battery is low.
If the scanner stops emitting a laser beam when you press the trigger, check your battery level. When the battery is low, the scanner shuts off before the terminal notifies you of the low battery condition. Note: If the scanner is still not reading symbols, contact your distributor or Symbol Technologies.
Note: If, after performing these checks, the terminal is still not reading symbols, contact your distributor or Symbol Technologies.
13-8