Configuring the Terminal

3. Click on the file(s) and/or directory in File Explorer. Note: Optionally, use the standard Windows Shift+Left-click and Control+Left-click features to select multiple files and directories. 4. Drag and drop the selected file(s) and/or directory from File Explorer to the target directory in the Script Window, OR Click on the target directory and select the File Explorer Copy icon from the toolbar and paste into the target directory in the Script Window.

Save the Script To save the changes to a new script: 1. From the File menu, choose Save As, OR On the toolbar, click on

.

2. Enter the path and filename. TCM appends a .TCM extension to the script. 3. Choose the OK button. Note: If you save an untitled script, TCM by default saves the script to the directory that the Script Browser is pointing to. To save changes to an existing script: •

From the File menu, choose Save, OR

•

On the toolbar, click on

.

Note: If you open and make changes to an existing script, saving the changes writes over the existing script. If you wish to use an original or Symbol-supplied standard script as a base and save the changes in a new script, use Save As instead of Save after making the changes, and save to a different filename.

12-9

Page 270

PDT 8000 Series Product Reference Guide

Building the Image As part of the build, TCM performs a check on the script which verifies that all files referenced in the script exist. If the image is bootable, TCM verifies that the boot files are available. Note: Performing a check is more important for previously existing scripts to ensure that files referenced in the script are still in the designated locations. To check a script: 1. In the Script Window, select the script. 2. Save the script, if not already saved. 3. From the Script menu, choose Check, OR On the toolbar, click

.

4. TCM verifies that files referenced in the script exist on available drives and lists an error message in the Errors found box for any missing files. 5. Choose the OK button to exit. To build a script: 1. In the Script Window, select the script to be built. 2. From the Script menu, choose Build, OR On the toolbar, click

12-10

. The Configure Build window appears.

Page 271

Configuring the Terminal

3. Select the item to build. If you select to build an application, specify the application. 4. Select ASCII format for your hex image, or Compression, which reduces the size of most hex images in order to speed downloading. 5. Click OK. 6. TCM performs a check. If the script has no errors, TCM proceeds with the build.

If the Build Fails If the build fails, TCM displays a message indicating which file(s) are missing. If the total amount of flash required by the script exceeds the image size, a TCM error results. To correct this, reduce the number of files in the volume, or make the disk nonbootable. Refer to Defining Script Properties on page 12-6 for more information on setting the image size appropriately.

12-11

Page 272

PDT 8000 Series Product Reference Guide

Sending the Hex Image Once the hex file is built, you are ready to download it to the terminal. A Hex image download requires both TCM and a program loader stored on the terminal. The terminal comes with a program loading utility, Initial Program Loader (IPL), stored in the terminal’s write-protected flash. To run IPL, the terminal must be connected to a development PC by direct serial connection.

Connect the Terminal and Development PC To send the hex file to the terminal, first connect the terminal and development PC by one of the following devices: •

Serial Charging Cable (p/n 25-55853-01)

•

Single-Slot Serial Cradle (p/n CRD8000-1000S).

Set Up IPL to Receive the File Note: IPL only recognizes files in the 8.3 format (file names can have up to eight characters, followed by a period and an extension of up to three characters). It does not support long file names.

64MB RAM Configuration To set up IPL on the terminal to receive the files being downloaded via TCM: Note: Terminal display is in landscape mode in IPL. Therefore, rotate your terminal 90 degrees to the right to read the display correctly. 1. Hard reset the terminal by removing the battery door and pressing the Power key and a Scan button, simultaneously. 2. Press the 5 key when three } appear on the bottom left of the screen.

12-12

Page 273

Configuring the Terminal

3. IPL displays the Main Menu which lists the partitions/applications that can be downloaded.

IPL * Platform Application Config Data Windows CE Monitor Splash Screen Power Micro Partition Table Update from CF Auto Select

Timer: OFF

4. Use the up and down scroll buttons to select the partition to be received, then press the Enter button. a. Auto Select is the default, and will be selected if no other selection is made within 10 seconds. b. If you select Update from CF, skip to step 9b. Note: If the platform application or data partition sizes are changed, you must download a new partition table first.

12-13

Page 274

PDT 8000 Series Product Reference Guide

5. IPL displays the Select Transport screen which lists the available methods of downloading the file.

Select Transport * Serial - No Flow Serial - RTS/CTS Serial - Xon/Xoff Previous Top

Timer: OFF

6. Use the up and down scroll buttons to select the method of transport, then press the Enter button. 7. IPL displays the Select Baud Rate screen which lists the available baud rates for the serial connection.

Select Baud Rate * 115200 57600 38400 19200 9600 Previous Top

Timer: OFF

8. Use the up and down scroll buttons to select the appropriate baud rate, then press the Enter button.

12-14

Page 275

Configuring the Terminal

9. The following screen allows you to confirm your download. Use the up and down scroll buttons to make the appropriate selection, then press the Enter button.

Download File? Download Cancel Show Parms Previous Top

Timer: OFF a. You can select Show Parms to view a summary of all the selections you have made in the previous steps. b. If you selected Update from CF in step 4, the following confirmation screen displays. Use the up and down scroll buttons to make the appropriate selection, then press the Enter button.

Download File(s) From CF? Download Cancel Previous Top

Timer: OFF

10. When the entire image is received, IPL indicates that the download is complete. a. If you selected Serial in step 5, the terminal will indicate a “waiting for input” message. In TCM, select the desired file and press download. The download

12-15

Page 276

PDT 8000 Series Product Reference Guide status screen will then appear. When complete, press the Enter button to return to the main menu. b. If you selected Auto Select in step 4, the terminal will automatically return to the main menu once download is complete. c. If you selected Monitor in step 4, the terminal will reboot once download is complete. 11. When all partitions are downloaded successfully, hard reset the terminal by removing the battery door and pressing the Power key and a Scan button, simultaneously.

128MB RAM configuration To set up IPL on the terminal to receive the files being downloaded via TCM: Note: Terminal display is in landscape mode in IPL. Therefore, rotate your terminal 90 degrees to the right to read the display correctly. 1. Hard reset the terminal by removing the battery door and pressing the Power key and a Scan button, simultaneously. 2. Press the 5 key when three } appear on the bottom left of the screen. 3. IPL displays the Main Menu which lists the partitions/applications that can be downloaded.

IPL * Platform Application Data Windows CE Monitor Splash Screen Power Micro Partition Table Auto Select

Timer: OFF

4. Use the up and down scroll buttons to select the partition to be received, then press the Enter button. Auto Select is the default, and will be selected if no other selection is made within 10 seconds. 12-16