Page 127

Communications

With a modem connection, you can use ActiveSync to synchronize data between your terminal and host computer (see Using ActiveSync on page 4-21) or you can connect to the Internet (see Launching the Internet on page 4-22).

Using ActiveSync 1. Tap Start - Settings - System - eConnect and ensure the following settings are made:

2. Tap the OK button.

4-21

Page 128

PDT 8000 Series Product Reference Guide

3. Tap Start - ModemSync. The modem dial-out commences and, if successful, a series of dialog boxes pop-up in succession, as shown below:

4. After connecting, ActiveSync starts and synchronizes with the host computer. 5. To disconnect, tap the Stop button on the ActiveSync screen.

Launching the Internet 1. Tap Start - Settings - System - eConnect and ensure the following settings are made:

4-22

Page 129

Communications

2. Tap the OK button. 3. Tap Start - ModemSync. The modem dial-out commences and, if successful, a series of dialog boxes pop-up in succession, as shown below:

4. When connected, Internet Explorer starts. You can now surf the Internet, if permitted by your server. 5. To disconnect, tap the two arrows on the navigation bar to expose the Connected dialog box. 6. Tap the End button.

Country Setup The modem defaults to operation with US telephone networks (country code: B5). To operate the modem with other country telephone networks, you must set the Country Code by entering the Country of Installation command. The modem will adjust it’s operating parameters to comply with the telephone network in the country specified. Edit Extra dial-string modem commands: text box to set country parameters. The syntax used is: +GCI=<country_code>; The supported countries and there codes are: Country

Code

Country

Code

Country Norway

Code

Austria

FD or 0A

Greece

46

FD or 82

Belgium

FD or 0F

Iceland

FD

Portugal

8B

Brazil

16

Ireland

FD or 57

Spain

FD or A0

4-23

Page 130

PDT 8000 Series Product Reference Guide

Country

Code

Country

Code

Country

Code

Canada

20

Italy

FD or 59

Sweden

FD or A5

Denmark

FD or 31

Liechtenstein

FD

Switzerland

FD or A6

Finland

FD or 3C

Luxembourg

FD

TBR-21 (Europe)

FD

France

FD or 3D

Mexico

73

United Kingdom

FD or B4

Germany

FD or 42

Netherlands

FD or 7B

United States

B5 (Default)

Note: It is highly recommended that you use FD where possible. If you have trouble connecting, use the alternate code where provided.

4-24

Page 131

Communications

Using a Four-Slot USB-to-Ethernet Cradle Note: The four-slot USB-to-Ethernet cradle can only be used with the 128MB RAM configuration. In order to establish a connection between the terminal and the host computer to communicate over an Ethernet network, the following must be done: • configuration of the terminal

• configuration of the host computer

• configuration of the DHCP server

• configuration of the cradle.

Configuration of the Terminal When you insert a terminal into the cradle, the cradle provides a direct-connect RAS service. You need to configure each terminal for use with the cradle, just as you would configure any remote client to connect to an Internet Service Provider (ISP). To configure the terminal install eConnect. See Installing eConnect on page 4-9.

Configuration of the Host Computer The host computer that you intend to synchronize with the terminal must be setup with the appropriate communication software and connection settings. This guide assumes that you are using Microsoft® ActiveSync software on both the terminal and the host computer. To configure the host computer: 1. Download and install ActiveSync. See Installing ActiveSync on page 4-3. 2. Configure the connection settings. The host computer must be configured for TCP/ IP network communications. a. Click on the ActiveSync icon from the system tray b. Tap File - Connection settings. c. In the Connection settings dialog box, select the Allow Network (Ethernet) and Remote Access Service (RAS) server connection with this desktop computer option. You may have other options selected, for example, Allow serial cable or infrared connection to this COM port. d. Click the OK button.

4-25

Page 132

PDT 8000 Series Product Reference Guide

Note: Before communicating through an ethernet connection, you must create a partnership between your terminal and your host computer. See Setting up a Partnership on page 4-4 for detailed instructions.

Configuration of the DHCP Server If you use a DHCP server to distribute IP addresses and other network parameters, setup the server as following: •

IP address pool (1 or 5 IP address per cradle)

• router/gateway address

• one or more DNS server addresses

• one or more WINS server addresses

• the subnet mask. Note: To assign the initial cradle IP address, you can either use a DHCP server, as shown above, or use the MobileDox Cradle Manager, as illustrated in Configuration of the Cradle on page 4-26. DHCP server is the preferred method.

Configuration of the Cradle The MobileDox Cradle Manager allows you to setup the Device IP Address and modify cradle settings. See Installing MobileDox Cradle Manager on page 4-9 for instructions to download and install the software.

4-26

Page 133

Communications

Connecting the Cradle Setup the four-slot USB-to-Ethernet cradle as shown below:

To Ethernet Hub

Figure 4-15. Setting up the Four-Slot USB-to-Ethernet Cradle Setting the Device IP Address By default, the cradle will use DHCP to obtain its IP address. However, if DHCP fails, the Cradle Manager can assign an IP address. Note: This is used if your cradle is connected to the network, however fails to appear in MobileDox. Enter the hardware device (MAC) address to locate the cradle and assign it a new IP address. 1. Launch the MobileDox Cradle Manager on your host computer.

4-27

Page 134

PDT 8000 Series Product Reference Guide

2. Click File - Set IP Address of Unlisted Device. The following screen appears:

3. Enter the appropriate MAC Address and IP address. 4. Click the OK button. Modifying Cradle Settings 1. Launch the MobileDox Cradle Manager on your host computer. 2. Select the name of the cradle you want to configure from the list. 3. Click Device - Modify Settings. 4. Use the General Settings tab to modify the identification settings of the cradle. Field

4-28

Description

Device Name

A text string used to describe the MobileDox device. Any 15character string may be entered.

Custom String

A text string for any desired usage (examples are: location, asset ID, etc.). Any 15-character string may be entered.

Require Admin Privileges to Modify Settings checkbox

Selecting this checkbox will require users to have administrative privileges in order to modify MobileDox settings. Administrative privileges are validated using standard Windows authentication.

Page 135

Communications

5. Use the TPC/IP Settings tab to modify the DNS and WINS identification settings of the cradle. Field

Description

Use DHCP

If checkbox is selected, necessary information will be retrieved from the DHCP server. If checkbox is not selected, static configuration will be used (information needs to be entered).

IP Address

The IP address that the MobileDox will use when communicating on the network.

Subnet Mask

The subnet mask that the MobileDox will use when communicating on the network.

Gateway Address

The IP address that the MobileDox will use to send non-local IP network data.

DNS Address

The IP address of a server(s) that can resolve Internet names into IP addresses.

WINS Address

The IP address of a server(s) that can resolve Windows network names into IP addresses. This field must be populated correctly when using ActiveSync.

4-29

Page 136

PDT 8000 Series Product Reference Guide

6. Use the Port Settings tab to modify the USB port settings of the cradle. Field

Description

Port Name

A text string used to describe the device attached to the port. Any 15character string can be entered. You can specify up to four port names, one for each of the cradle’s slots.

IP Address

The IP address assigned to the cradled device. There should be one IP address per cradle slot. This box will be disabled for all devices if DHCP is used to obtain the IP address.

Use DHCP to obtain IP Address checkbox

The cradle will use DHCP to obtain an IP address for the handheld. Unchecking this selection allows the cradle to use Static IP address for the handheld.

Use NAT checkbox

The cradle will use Network Address Translation (NAT) when forwarding handheld traffic onto the network. No IP addresses are necessary for the handhelds. This must be disable when using ActiveSync.

7. Click the OK button.

Using ActiveSync 1. Review the configuration of the cradle using the MobileDox Cradle Manager. a. A WIN server must be present on your network. Ensure that the WINS Address provided in the TCP/IP Settings tab matches the IP address of the WIN server on your network. b. Ensure that the Use NAT checkbox is not selected in the Port Settings tab.

4-30