Page 152

PDT 7500 Series Product Reference Guide for Windows® CE

Printer Setup This option allows you to customize the terminal’s printer settings.

Figure B-13. Control Panel Printer Setup screen

Selected Printer This option allows you to select the printer to be used. To change the printer, tap the Selected Printer field to scroll through the available printers. Alternately, use your up and down arrow keys to highlight the Selected Printer field, then use your left and right arrows to scroll through the list of available printers.

Printer Parameter This option allows you to set the communication parameter associated with the selected printer. To change the communication parameter, tap the Printer Parameter field, and select the appropriate communication parameter for your printer. Alternately, use your up and down arrow keys to highlight the Printer Parameter field, and then use the left and right arrow keys to select the appropriate communication parameter for your printer.

Version Info This option displays the Printer API version number.

B-10

Page 153

Demo Program

Communication Settings This option allows you to select the communication settings used by the PC Link.

Figure B-14. Control Panel Communication Setup screen

Comm Settings This option allows you to select the appropriate communication settings to be used by the PC Link. To select the correct settings, tap the Comm Settings field, and scroll through the communication settings to select the appropriate value. Alternately, use the up and down arrow keys to highlight the Comm Settings field, then use the left and right arrow keys to scroll through the values until the appropriate value is selected.

Unique Unit ID This option displays the terminal’s unique unit ID (a 16byte hex number identifier), and the version numbers for the RCM (Resource Coordinator Manager) API, Rescoord (Resource Coordinator) DLL, UUID DLL, and Temperature DLL.

Figure B-15. Control Panel Unique Unit ID screen

B-11

Page 154

PDT 7500 Series Product Reference Guide for Windows® CE

Power Management This option displays the version number of the Power API and allows you to set system and backlight parameters.

Figure B-16. Control Panel Power Management screen

Version Info This option displays the Power API versions.

Power Info This option displays the battery type, the battery power status, and the power source.

Figure B-17. Control Panel Power Info screen

System This option allows you to view and set the device state, activity mask, wakeup source, and device time-outs. To navigate through the options, either tap the option, or use the up and

B-12

Page 155

Demo Program down arrow keys to highlight the option, then use the left and right arrows to select the correct value.

Figure B-18. Control Panel Power Management System screen

Backlight This option allows you to view and set the backlight parameters, including the device state, the activity mask, and the backlight timeout.To navigate through the options, either tap the option, or use the up and down arrow keys to highlight the option, then use the left and right arrows to select the correct value.

Spectrum24 Configuration Refer to Chapter 8, Spectrum24 Network Configuration, for details on this option.

Memory Adjustment This option allows you to adjust the use of the available memory, dividing it between storage memory and program memory.

Figure B-19. Control Panel Memory Adjustment screen

B-13

Page 156

PDT 7500 Series Product Reference Guide for Windows® CE

To adjust the memory usage, tap the arrow keys on the screen, or use the up and down arrow keys on the keypad, until the memory is allotted as needed to storage and program space.

Cradle This option allows you to configure the cradle parameters.

Figure B-20. Control Panel Cradle screen !

!

B-14

Cradle Mode " Single Mode " Multi Mode " Manual Mode API Version - Displays the version of the Cradle driver

Page 157

Demo Program

System Version This option displays the version of the various System components.

Figure B-21. Control Panel System Version screen ! ! !

Wince Version - The version of Windows CE that is running on the terminal. OEM Version - Build version of the Operating System. Loader Version - Build version of the System loader.

Scan Sample This option provides a sample scanning application (ScanSamp2.exe), which allows you to change scanner parameters, perform scanning, and display scanned data.

Figure B-22. Scan Sample screen

Scanning Data Fields Once you scan a bar code, the following fields display: B-15

Page 158

PDT 7500 Series Product Reference Guide for Windows® CE

Data Displays the decoded data.

Type Displays the label type in hex format.

Src Displays the scanner used, and the bar code type in ASCII format.

Scan Sample Options Menu Pressing Enter from within the Sample Scan application causes the following menu to appear:

Figure B-23. Scan Sample Pop-Up Menu

Params This menu option allows you to change scanning parameter options, such as: ! ! ! ! !

Beep Time: the length of the good decode beep, in ms. Beeper Frequency: the beeper tone, in Hz. LED On Time: the length of time the LED remains on upon successful decode. Code ID: Bar Code Identifier character. Wav File: the sound of the decode beep, can be customized; not available on the PDT 7500 terminal.

Config This menu option sets the code types the terminal can decode, and sets the options for each code type.

B-16

Page 159

Demo Program

ViewData This menu option displays the decoded data on a separate screen.

Figure B-24. ViewData Screen

About This menu option displays the scan sample application version string.

Exit This menu option exits the scan sample application.

PC Link PC Link (Repllog.exe) is a connectivity program. It communicates with ActiveSync running on the Host PC.

Figure B-25. PC Link screen Note: Before connecting your PC, select the proper communication device in the control panel.

B-17

Page 160

PDT 7500 Series Product Reference Guide for Windows® CE

About OTL This item on the Program Launcher screen displays the version and copyright strings for the Otl.exe program.

Figure B-26. About OTL screen

ScanImage Sample This program provides a sample imager scanning application (ScanImage), which demonstrates the image and signature capture capabilities on Imager models of the PDT 7500.

Figure B-27. Scanner Imaging Sample Main Window

B-18