The text of a manual · part 17 of 24
PDT 7500 Series Product Reference Guide for Windows CE: Chapter 11 Maintenance and Troubleshooting
Pages 133 to 138 of 190, from PDT 7500 Series Product Reference Guide for Windows CE
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PDT-7500, Symbol PDT-7540, Symbol PDT-7542 and Symbol PDT-7546
Page 133
Chapter 11 Maintenance and Troubleshooting Chapter Contents Chapter Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1 Cleaning the Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Terminal Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 Cradle Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6
11-1
Page 134
PDT 7500 Series Product Reference Guide for Windows® CE
11-2
Page 135
Maintenance and Troubleshooting
Cleaning the Terminal The PDT 7500 requires a minimal amount of maintenance. To prolong its life and avoid problems, keep the terminal clean. Use a clean, soft cloth dampened with a mild cleanser such as soap and water to clean the terminal. Do NOT use cleaners containing a high percentage of alcohol, such as Isopropyl Alcohol. Do NOT use abrasive paper/cloth or abrasive/ corrosive cleaners. Wipe the entire terminal, except for the scanner window. Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.
Storage If the terminal will not be used for longer than a week, store it in a cool, dry place away from dust. Remove the battery pack and repackage the terminal in its original shipping container. To store the terminal for a shorter period of time (a few days), leave the batteries in the terminal. Note that if the battery pack is left in the terminal for an extended amount of time, any data stored on the terminal may be lost. The Lithium-Ion battery pack must be kept charged to avoid loss of data. Note: If you leave the terminal without a main battery pack for longer than 5 minutes, the terminal will automatically reboot. All non-volatile data is lost and you must reset the date and time.
11-3
Page 136
PDT 7500 Series Product Reference Guide for Windows® CE
Terminal Troubleshooting Table 11-1 covers some common terminal problems and corrective actions to take. Table 11-1. Terminal Problems Symptom
Possible Cause
Terminal does not power up. Battery pack not installed or fully charged.
Action Verify that the battery pack is installed in the terminal. Charge the battery pack, either in the terminal for 2 hours, or separately for 5 hours.
Power supply is not plugged in. Verify that the power supply is connected properly to the terminal and plugged in the wall socket. Battery pack is not properly latched.
Make sure the battery properly latched.
Rechargeable Li-Ion battery did not charge.
Battery failed.
Replace battery.
PDT 7500 removed from cradle while battery was charging.
Insert PDT 7500 in cradle and begin charging. The Li-Ion battery requires 2 hours to recharge fully.
Cannot see screen.
Terminal not powered on.
Press the Power button on the terminal.
Contrast not adjusted properly. Press the blue FUNC key and then the Dark or Light keys to adjust contrast. Touch screen not working
Display not properly calibrated.
Scanner does not come on Scanner is not enabled. when scan button is pressed.
11-4
Recalibrate the screen through the control panel calibration utility. Make sure scanner software is configured correctly.
Page 137
Maintenance and Troubleshooting
Table 11-1. Terminal Problems (Continued) Symptom Scanner does not decode a bar code.
Battery life is inadequate.
Possible Cause
Action
Bar code is unreadable.
Verify that the bar code is not defective, i.e., smudged or broken.
Scan window is dirty.
Clean scan window with a lens tissue. Tissues for eyeglasses work well. Do not use tissues coated with lotion.
Symbology not enabled.
Verify with the programmer that the application is designed to perform scanning.
Battery pack not fully charged. Charge the battery pack, either in the terminal for 2 hours or separately for 5 hours. Battery pack is old.
Replace with a fresh, fully charged battery pack.
Terminal being used in lowtemperature conditions.
Battery life is shortened if used in extremely cold conditions.
Unnecessary peripherals draining power.
Disconnect any peripherals not used to reduce the drain on the battery pack. (For example, disable the scanner when it is not being used.)
The application is not designed Consider using power for efficient power use. management services provided in the Symbol Windows CE SDK to reduce drain on battery pack. Ensure the radio is at maximum power saving mode. The Imager is having trouble reading symbols.
Symbology disabled.
Check that the symbology is enabled.
Damaged symbol.
Be sure the symbols aren’t damaged or coated with frost or water droplets.
Improperly aligned symbol.
Be sure the symbol is completely within the aiming pattern.
11-5
Page 138
PDT 7500 Series Product Reference Guide for Windows® CE
Cradle Problems Table 11-2 lists some common cradle problems and actions to take to resolve them. Table 11-2. Cradle Troubleshooting Symptom No communication between terminal and cradle.
Probable Cause Incorrect communication device selected.
Action Ensure that the proper communication device is selected in control panel.
Terminal not seated properly in Reseat the terminal in cradle. cradle. Rechargeable battery pack in Battery failed. terminal or spare battery pack Terminal or battery pack was did not charge. removed from cradle too soon OR battery pack or terminal is improperly installed in cradle.
11-6
Replace battery pack Replace terminal and/or spare battery pack in cradle and begin charging over. Battery pack requires 2 hours while inside a terminal or 5 hours in a cradle’s spare battery charging slot to recharge fully.