Page 47

Chapter 4 Operating the Terminal Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Powering on the PDT 7500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Booting the Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Suspending and Resuming Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Adjusting the Display and Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Using the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Scanning Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Smart Raster Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Scanning Mode Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Scanning PDF417 Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Scanning (Imager). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Operational Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Aiming the Imager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Performing Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Communicating via RS-232 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Communicating via Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Spectrum24 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16

4-1

Page 48

PDT 7500 Series Product Reference Guide for DOS

Introduction This chapter describes how to operate a PDT 7500 terminal, including: powering the PDT 7500 booting the terminal ! adjusting the display’s contrast ! using the keyboard ! entering data through the integrated scanner ! communicating. ! Once the terminal is initialized and power is applied via a fully charged battery pack or a power source, it is ready for operation. !

Powering on the PDT 7500 Because the terminal is battery powered, it is important to save power whenever possible. You can minimize power loss and increase battery life by turning the terminal off when data is not being entered. While the terminal’s processor and display are off, programs or data in the system's memory are retained. Before the terminal powers up, it checks the batteries for enough power to ensure reliable operation and data storage. Power-up restores the display, and processing continues from where it was before power-down.

4-2

Page 49

Operating the Terminal

To power on the PDT 7500: 1. make sure a fully charged battery is installed in the terminal. 2. press the power key . To suspend the PDT 7500’s operation, press the power key again.

Booting the Terminal The warm boot process is similar to pressing the <Ctrl+Alt+Del> keys on a PC. To perform a warm boot, press and hold the power key for 6 seconds, then release. Cold booting the terminal generates a system reset, the same as a power-on boot on a standard PC. To cold boot the terminal, hold down the Power key for 15 seconds or for the amount of time set in Setup. See Chapter 8, Terminal Configuration: Setup for more information on Setup.

Suspending and Resuming Operation To suspend or resume operation, press the PWR key on the PDT 7500. The terminal can also resume operation from various wakeup sources (if enabled through the application). The wakeup sources available on the PDT 7500 are listed in Table 4-1. Note: The default for enabling/disabling these wakeup sources depends on how the terminal is suspended (manual suspend using the PWR key vs. automatic suspend via timeout). An application can also control the source of a terminal wakeup, overriding the defaults.

Table 4-1. PDT 7500 Wakeup Sources Source

Manual Default (PWR key)

Automatic Default (timeout)

PWR key and touch panel power area enabled enabled

AC adapter connect disabled enabled

Cradle insert/remove disabled enabled

Battery insert disabled enabled

4-3

Page 50

PDT 7500 Series Product Reference Guide for DOS

Table 4-1. PDT 7500 Wakeup Sources (Continued) Source

Manual Default (PWR key)

Automatic Default (timeout)

Scan trigger(s)

disabled enabled keyboard (any key)

disabled enabled

Touch pad (any touch)

disabled enabled

Alarm timer disabled enabled

PCMCIA Slot (0/1)

disabled enabled

COM ring (1/2)

disabled enabled

COM Rx Data (1/2)

disabled enabled

Terminal operation can be suspended in four ways: !

!

!

!

Manual suspension " the operator presses the PWR key. Refer to Table 4-1 for the default values. Automatic suspension " the terminal times out because of no operator activity. Refer to Table 4-1 for the default values. Program dependent suspension " the application requests a suspend via an API call " the application sets a wakeup Critical suspension " the battery pack is removed or is very low " PWR key is required to resume.

Adjusting the Display and Volume The terminal’s backlight illuminates the display in dimly lit areas. Note: Use of backlighting can significantly reduce battery life. To turn the backlight on or off, press the blue FUNC key, then press the LAMP key.

4-4

Page 51

Operating the Terminal

There are two ways to adjust the display’s contrast and backlight, and the speaker volume on the PDT 7500: !

! !

establish the initial values using the setup utility (refer to Chapter 8, Terminal Configuration: Setup). Contrast can be adjusting be pressing the FUNC key, then either the light or dark key. adjust the values through an application, if allowed by the software.

Scanning The PDT 7500 offers two scanning capability options: ! !

1-D standard PDF417 scanning. Note: The scanning application and scanner driver must be loaded on the terminal to perform scanning.

Using the Scanner To use the integrated laser scanner: 1. Verify that the system is on (the display is active). 2. Ensure that a scanning-capable application is loaded and running, and that the application is in a state to allow scanning. 3. Aim the scan window at the bar code. 4. Adjust the aim so that the thin, red laser beam covers the entire length of the bar code.

:URQJ

5LJKW

Optimal scanning distance varies with bar code density and scanner optics, but most combinations work within 4 to 10 inches. Generally: " Hold the scanner farther away for larger symbols. " Move the scanner closer for symbols with bars that are close together.

4-5

Page 52

PDT 7500 Series Product Reference Guide for DOS

5. Press the scan button. 6. If the decode is successful, the LED turns from yellow to green. The terminal may also beep. Note: The procedure for your scanner may differ from the one listed above. Scanner operation depends on the application.

Scanning Considerations Usually, scanning is a simple matter of aim, scan, and decode, and a few quick trial efforts master it. However, two important considerations can optimize any scanning technique, range and angle.

Range Any scanning device decodes well over a particular working range, minimum and maximum distances from the bar code. This range varies according to bar code density and scanning device optics. Scanning within range brings quick and constant decodes; scanning too close or too far away prevents decodes. So you need to find the right working range for the bar codes you are scanning. However, the situation is complicated by the availability of multiple integrated scanning modules, some with specialized capabilities such as long range and 2-D decode capability. The best way to specify appropriate working range per bar code density is through a chart called a decode zone for each scan module. A decode zone simply plots working range as a function of minimum element widths of bar code symbols. Decode zones for integrated scan elements available on the PDT 7500 are provided in Appendix A, Specifications.

Angle Scanning angle is important for promoting quick decodes. When laser beams reflect directly back into the scanner from the bar code, this specular reflection can “blind” the scanner. To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too sharp an angle; the scanner needs to collect scattered reflections from the scan to make a successful decode. Practice quickly shows what tolerances to work within.

4-6

Page 53

Operating the Terminal

Note: Contact the Symbol Support Center if you have chronic difficulties scanning. Decoding of properly printed bar codes should be quick and effortless.

Smart Raster Capability All integrated 1-D/PDF417 scan elements may be programmed for “Smart Raster” capability, which causes the scanner to emit a raster pattern dynamically optimized to the particular PDF417 bar code’s shape. To increase scanning efficiency and optimize decode time, the scanner determines the geometry of the bar code and opens at a rate and size optimal for decoding that bar code. In normal Smart Raster operation, a trigger pull causes a slab raster pattern to appear. If the target is a 1-D bar code, the slab raster decodes the bar code. If the target bar code is PDF417, the scanning patterns open up to a full, optimized raster pattern as soon as the scanner is properly aligned over the bar code (Figure 4-1). Aiming “Dot” Pattern

Aiming “Slab” Raster Pattern

Y-Axis

Y-Axis

Open Raster Pattern

Horizontal Displacement (X - Axis)

Figure 4-1. 1-D/PDF417 Scan Element Aiming and Scanning Patterns

4-7

Page 54

PDT 7500 Series Product Reference Guide for DOS

For best operation in Smart Raster mode, keep the scan pattern as parallel to the symbol’s rows as possible, keep the scanner as still as possible, and hold the scanner at an angle which does not give specular reflection (refer to Angle on page 4-6). The symbol should also be in good condition.

Scanning Mode Options There are three scanning options: aiming with a dot pattern, scanning with a slab raster pattern, or always raster.

Aiming Dot Option A trigger pull creates the single dot aiming pattern, which lasts for a fixed interval. This dot easily can be seen in outdoor or high ambient light environments. A slab raster pattern or an open raster pattern appears next, depending on the programmed scanning option. There are two programmable timeout periods for this option, normal and extended.

Slab Raster Aiming Option A trigger pull creates the slab raster pattern. If the target is a 1-D bar code, the slab pattern decodes the bar code. If the target bar code is PDF417, the pattern opens up to an optimized raster pattern as soon as the scanner is properly aligned over the bar code.

Always Raster Option When programmed to this option, the PDF417 scan element directly opens to a full raster pattern whenever the trigger is pulled.

Scanning PDF417 Bar Codes Make sure the terminal is programmed for a slab raster aiming pattern and Smart Raster mode. 1. Aim the scanner at the symbol. Try to keep the nose of the scanner parallel with the symbol’s rows. 2. Make sure the symbol you want to scan is within the scanning range; refer to the 1D/PDF417 decode zones. Then pull the trigger. The scan pattern first covers the symbol horizontally (Figure 4-2). Make sure the

4-8