Chapter 10 Maintenance and Troubleshooting Chapter Contents Cleaning the Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Terminal Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Cradle Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6
10-1
Page 116
PDT 7500 Series Product Reference Guide for DOS
10-2
Page 117
Maintenance and Troubleshooting
Cleaning the Terminal The PDT 7500 requires a minimal amount of maintenance. To prolong its life and avoid problems, keep the terminal clean. Use a clean, soft cloth dampened with a mild cleanser such as soap and water to clean the terminal. Do NOT use abrasive paper/cloth or abrasive/ corrosive cleaners. Wipe the entire terminal, except for the scanner window. Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.
Storage If the terminal will not be used for longer than a week, store it in a cool, dry place away from dust. Remove the battery pack and repackage the terminal in its original shipping container. To store the terminal for a shorter period of time (a few days), leave the batteries in the terminal. Note that if the battery pack is left in the terminal for an extended amount of time, any data stored on the terminal may be lost. The Lithium-Ion battery pack must be kept charged to avoid loss of data. Note: If you leave the terminal without a main battery pack for longer than 20 minutes, reboot the terminal to reset the date and time.
10-3
Page 118
PDT 7500 Series Product Reference Guide for DOS
Terminal Troubleshooting Table 10-1 covers some common terminal problems and corrective actions to take. Table 10-1. Terminal Problems Symptom
Possible Cause
Terminal does not power up. Battery pack not installed or fully charged.
Action Verify that the battery pack is installed in the terminal. Charge the battery pack, either in the terminal or separately, for a full 2 hours.
Power supply is not plugged in. Verify that the power supply is connected properly to the terminal and plugged in the wall socket.
Cannot see screen.
Battery pack is not properly latched.
Make sure the battery properly latched.
Terminal not powered on.
Press the Power key on the terminal.
Contrast not adjusted properly. Press the blue FUNC key and then the Dark or Light keys to adjust contrast. Touch screen not working
Display not properly calibrated.
Recalibrate the screen through calib75.com.
Scanner does not come on when trigger pressed.
Scanner driver is not loaded.
Verify that scanner driver is loaded on the terminal. Check application software to ensure that scanner driver is properly referenced.
Scanner does not decode a bar code.
Bar code is unreadable.
Verify that the bar code is not defective, i.e., smudged.
Symbology not enabled.
Verify with the programmer that the application is designed to perform scanning.
10-4
Page 119
Maintenance and Troubleshooting
Table 10-1. Terminal Problems (Continued) Symptom Battery life is inadequate.
Possible Cause
Action
Battery pack not fully charged. Charge the battery pack, either in the terminal or separately, for a full 2 hours. Battery pack is old.
Replace with a fresh, fully charged battery pack.
Terminal being used in lowtemperature conditions.
Battery life is shortened if used in extremely cold conditions.
Unnecessary peripherals draining power.
Disconnect any peripherals not used to reduce the drain on the battery pack.
The application is not designed Consider using power for efficient power use. management services provided in Series 7000 SDK to reduce drain on battery pack. Formatting SRAM card causes size error. Can’t access SRAM card.
SRAM card is corrupt; the card Use SRAMINIT utility, format changed or was discussed in Chapter 9 to recorrupted. initialize the card.
Can’t boot from SRAM card (COMMAND.COM not found).
10-5
Page 120
PDT 7500 Series Product Reference Guide for DOS
Cradle Problems Table 10-2 lists some common cradle problems and actions to take to resolve them. Table 10-2. Cradle Troubleshooting Symptom No communication between terminal and cradle.
Probable Cause
Action
Cradle driver not loaded.
Ensure that the cradle driver is loaded.
Cradle mode was disabled by an API call.
Re-enable cradle mode via the appropriate API.
Terminal not seated properly in Reseat the terminal in cradle. cradle. Rechargeable battery pack in Battery failed. terminal or spare battery pack Terminal or battery pack was did not charge. removed from cradle too soon OR battery pack or terminal is improperly installed in cradle.
10-6
Replace battery pack Replace terminal and/or spare battery pack in cradle and begin charging over. Battery pack requires 2 hours to recharge fully.