Page 106

Appendix A Specifications Environment The PDT 7200 is designed to operate in harsh environments. Table A-1 below summarizes the PDT 7200’s intended operating environment. Table A-1. PDT 7200 Operating Environment Operating Temperature

-20° C to 50° C (-4° F to 122° F)

Humidity

0% to 95% non-condensing

Shipping and Storage Temperature

-30° C to 60° C (-22° F to 140° F)

Electrostatic Discharge

±15 kv

Drop to Concrete

1.4 meters (4 ft.) 1.8 meters (6 ft.) with optional rubber boot

Sealing

IP 54 and IPC 529 (splashing water and dust)

A-1

Page 107

PDT 7200 Series Product Reference Guide for Windows® CE

Decode Zones Standard Range 11.7 29.75 Integrated Scanner

5

12.7

0

0

5

12.7

.005 In. Depth of Field in Inches

.0075 In. .020 In. Minimum Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 12 0

4

6 12.7

8

11.7 29.75 In. Cm.

Width of Field in Inches / Centimeters

NOTE: Typical performance at 68o F ( 20o C) on high quality symbols.

10 12 14 16 18 20 22 24 26 28 30 32 34 In. 25.4 38.1 50.8 63.5 76.2 86.4 Cm.

Decode Zone: Depth of field as a function of minimum element width.

Long Range 11.7 29.75 Integrated Scanner

.010 In.

Depth of Field in Inches

.015 In. Min. .020 In. Minimum Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 0

5

10 15 20 25 30 35 40 45 50 25.4 50.8 76.2 101.6 127

5

12.7

0

0

5

12.7

11.7 29.75 In. Cm.

55

60 65 70 In. 152.4 177.8 Cm.

Long Range Decode Zone: Depth of field as a function of minimum element width.

A-2

Width of Field in Inches / Centimeters

NOTE: Typical performance at 68o F ( 20o C) on high quality symbols.

Page 108

Specifications

NOTE: Typical performance at 68o F ( 20o C) on high quality symbols. Y-module dimension = 3 X.

10

25.4

5

12.7

0

0

5

12.7

8 10

25.4

In.

Cm.

8 6 Integrated Scanner

4 2 2 4

.006 In.

Depth of Field in Inches

6

.0075 In. .020 In. Min. Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 12 0

4

6 12.7

8

10 12 14 16 18 20 22 24 26 28 30 32 25.4 38.1 50.8 63.5 76.2

Width of Field in Inches / Centimeters

SE 2000 1-D Decode Zone

In. Cm.

SE 2000 Decode Zone: Depth of field as a function of minimum element width.

Integrated Scanner

Depth of Field in Inches

4

10.2

2

5.1

0

0

2

5.1

4

10.2

.0066 In. .010 In. Minimum Element Width

In. Cm.

.015 In. Minimum Element Width 2

4

6

8

10

12

14

In.

0 2.5 5.1

0

1

10.1

15.2

20.3

25.4

30.5

35.6

Cm.

Width of Field in Inches / Centimeters

SE 2000 2-D Decode Zone (PDF417)

A-3

Page 109

PDT 7200 Series Product Reference Guide for Windows® CE

Pin-Outs Pin

Description

1

GND

2

DSR

3

RXD

4

CTS

5

DCD

6

GND

7

PWROUT (+5V)

8

Reserved

9

DTR

10

Ring

11

TXD

12

RTS

13

Reserved

14

GND

15

Reserved

A-4