For the Symbol PDT-7200
Page 114
Chapter 9 Terminal Configuration: Setup Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 Invoking Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Main Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11 Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
9-1
Page 115
PDT 7200 Series Product Reference Guide
9-2
Page 116
Terminal Configuration: Setup
Introduction The PDT 7200 Series terminal has a system setup program that allows you to configure many of the terminal’s basic characteristics. Specifically, the setup program is made up of five screens and defines: • contrast value
• backlight
• beeper volume
• suspend time
• backlight time
• boot sequence
• reset time
•
CPU speed
• system date and time.
Setup also displays the Terminal Type and RAM and Flash sizes. This describes how to set each of these default values using the setup program.
Navigating Setup The setup program is a touch-sensitive application, so use your finger to tap the buttons on the screen.
9-3
Page 117
PDT 7200 Series Product Reference Guide
Invoking Setup To invoke the setup application: 1. Start the terminal by performing a cold boot (press the power button without holding the trigger until the terminal reboots). While the terminal is booting, a message displays on the bottom of the screen, “Hold Trig for Setup”. 2. Press and hold the scan trigger button, until the setup application starts. The Symbol PDT 7200 Setup screen displays, providing the menu of setup options for selection.
Figure 9-1. PDT 7200 Setup Screen
Defaults Selecting the Defaults option on the main setup screen displays the Reset Confirmation screen, which allows you to confirm your request to reset the terminal’s features to the
9-4
Page 118
Terminal Configuration: Setup factory defaults. To cancel the reset and return to the Main Setup screen, tap the CANCEL option. To confirm the resetting of default values, tap the RESET DEFAULTS option.
Figure 9-2. Set Defaults Screen
9-5
Page 119
PDT 7200 Series Product Reference Guide
Main Setup Selecting the Main Setup option on the PDT 7200 Setup screen displays the Main Setup screen.
Figure 9-3. Main Setup Screen This screen allows you to set the system clock for the terminal, and set the desired screen contrast, backlight, and beeper volume. To change the values in any of the fields, tap with your finger to highlight the field, then use the up and down arrow buttons to scroll through the available options for each field. When the correct value is entered in each field, tap OK. Tap CANCEL to exit this screen without saving changes and return to the PDT 7200 Setup screen.
9-6
Page 120
Terminal Configuration: Setup
Advanced Selecting the Advanced option on the PDT 7200 Setup Screen displays the Advanced Setup screen.
Figure 9-4. Advanced Setup Screen This screen allows you to set the reset time, which is the period of time in seconds that the power icon must be pressed to cold boot the terminal; the boot sequence, which defines the order in which the system should boot, and the allowable CPU speed. To change the reset time, tap in the Reset Time field, and use the up and down arrow buttons to change the value. The Boot Sequence and CPU Speed fields each have pull-down menus to select from. When you tap on the field, the pull-down menu displays. When the desired values are displayed in all the fields, tap OK. Tap CANCEL to return to the PDT 7200 Setup screen without saving changes made to this screen. Note: The boot sequence is ignored unless the compact flash is present. If compact flash is present, and removable/fixed is selected, then the
9-7
Page 121
PDT 7200 Series Product Reference Guide compact flash is drive C: and the on-board flash drives are drives D: and upwards. If compact flash is selected and fixed/removable is selected, then the first on-board flash is drive C:, the compact flash is drive D: and the remaining on-board flash disks are drive E: and upwards.
Power Selecting the Power option on the PDT 7200 Setup screen displays the Power Settings screen.
Figure 9-5. Power Settings Screen This screens allows you to define: •
Suspend Timer: the period of inactive time after which the terminal suspends, in minutes and seconds.
•
Backlight Timer: the period of time after which the backlight turns off, in minutes and seconds.
9-8
Page 122
Terminal Configuration: Setup
•
Highspeed Time: defines how long the CPU stays at 66 MHz when the system does not detect any activity before dropping to 33 MHz. The following table illustrates the times associated with each value. Timer Value
Time at 66 MHz (in second)
0
Does not drop to 33 MHz
1
0.125
2
0.25
3
0.5
4
1
5
4
6
8
7
16
Note: This field has no effect unless the CPU speed is set to 66 MHz. Higher numbers increase power consumption. To modify the values in any of these fields, tap the field to be changed, and use the up and down arrow keys to select the appropriate value. When all fields display the correct values, tap OK to accept. Tap CANCEL to exit this screen without saving the changes, and return to the PDT 7200 Setup screen.
9-9
Page 123
PDT 7200 Series Product Reference Guide
Information Selecting the Information option on the PDT 7200 Setup screen displays the System Information screen.
Figure 9-6. System Information Screen This screen is a read-only screen which displays: •
Machine Name: displays the terminal name
•
RAM Size: displays the size of the RAM disk on the terminal
•
Flash Size: displays the size of the Flash disk on the terminal.
After reviewing the data on this screen, tap OK to return to the PDT 7200 Setup screen.
9-10
Page 124
Terminal Configuration: Setup
Password Selecting the Password option on the PDT 7200 Setup screen displays the Password Setup screen.
Figure 9-7. Password Setup Screen To select a numeric password for your terminal, tap the desired numbers. As they are selected, they display in the Password field. Tap clear to clear the data from the password field. Tap OK to accept the password entry and return to the PDT 7200 Setup screen. Tap CANCEL to return to the PDT 7200 Setup screen without selecting a password. Note: A custom set up is required to activate the password. The password can be used to make individual setup fields read-only or invisible.
9-11
Page 125
PDT 7200 Series Product Reference Guide
Exit Selecting the Exit option from the PDT 7200 Setup screen displays the Exit Confirmation screen.
Figure 9-8. Exit Confirmation Screen This screen allows you to determine how you want to exit the setup. To cancel the exit request, tap CANCEL. To save the changes you’ve made to the setup, tap SAVE AND EXIT. To exit without saving the changes you’ve made to the setup, tap EXIT.