Chapter 3 Batch and Spectrum One Terminal Setup Introduction Before using the PDT 6800 Series terminal, perform the following: !

Install the battery (refer to Chapter 6, Maintaining the Terminal)

!

Charge the battery (refer to Chapter 6, Maintaining the Terminal)

!

Load the system files and application(s) (refer to Series 3000 Application Programmer’s Guide p/n 70-16308-XX).

Hardware Requirements Following is the equipment required to initialize a batch or Spectrum One radio terminal: !

PDT 6800 (batch) or PDT 6810 (Spectrum One) terminal

!

One or more CCM 38/6860 or CRD 38/6866, or a CRD 38/6865

!

OR

!

PC adapter with Printer Interface Module (PIM)

!

RS-232 null modem cable

!

Power Supply

!

Host Computer.

Refer to Chapter 2, Accessories Setup for setting up the cradles or PC Adapter for communications.

3-1

Page 41

PDT 6800 Series Product Reference Guide

Communications For terminals being used in a direct communications (batch) environment or a Spectrum One network environment, applications are transferred from a host computer to the terminal: !

over a communications line using a null modem connected to the cradle

!

OR through the PC Adapter.

The procedure uses the SENDHEX program on the host computer and the Program Loader function (from Command Mode) on the terminal. Programs are stored in the terminal’s nonvolatile memory (NVM), also called the application EEPROM. Note: For details on the SENDHEX program, refer to the Series 3000 Application Programmer's Manual. Other software may be used in place of the SENDHEX program.

Downloading the Program To download the program, initiate the communications software on the host computer and terminal as described in the following sections. Note: To cancel communications at any time during the session, press CLEAR on the terminal. The session stops immediately. Communications parameters specified on the host and the terminal must match. These parameters typically are: 38400 bps 7-bit parity Odd parity Xon/Xoff flow control To program the EEPROM, the terminal must be connected to the host through a cradle, CCM 38/6860, or PC Adapter with PIM.

3-2

Page 42

Batch and Spectrum One Terminal Setup

Initiate Host Communications Software If using a cradle (CCM 38/6860, CRD 38/6866, CRD 38/6865), do steps 1-3. Otherwise continue with step 4. 1. Connect the cradle to the host computer. Refer to Chapter 2, Accessories Setup. 2. Power on the cradle. 3. Place the terminal in the cradle. 4. Connect the PC adapter. 5. Power on the host computer. 6. Start the communications program. 7. At the DOS prompt, enter the SENDHEX command: sendhex pgmname 38400 com2 where: SENDHEX is the command pgmname is the application being loaded (.hex extension is optional)

parameters are the communications parameters following the program name. Parameters include baud rate, communications port, data bits, parity, and flow control. To accept the default parameters, do not enter a value.

In the example, the baud rate is set to 38400 bps and the communications port to COM2. The default values are accepted for the remaining parameters. Note: Versions of SENDHEX earlier than 3.0 do not support flow control. If you use an earlier version and encounter communication errors, use a lower baud rate. 8. SENDHEX displays the prompt: Press <Enter> to begin communications.

9. Do NOT press <ENTER> yet. Before starting communications (refer to Starting Communications on page 3-6), set up the terminal as described in Initiate Terminal Communications.

3-3

Page 43

PDT 6800 Series Product Reference Guide

Initiate Terminal Communications 1. Boot the terminal to command mode. For the 35-Key terminal: "

Press and hold <BKSP> and <SHIFT>.

"

Press and release PWR.

"

Release <BKSP> and <SHIFT>.

For the 46-Key terminal: "

Press and hold <F> and <I>.

"

Press and release <PWR>.

"

Release <F> and <I>.

The terminal displays: COMMAND MODE Select function Self test

2. Scroll through Command Mode options using UpArrow or DownArrow until "Program loader" is displayed. Press <ENTER>. 3. The terminal displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>

Before loading the new application, erase the NVM’s original contents. Note: To cancel this operation, press CLEAR. 4. Press <ENTER> to erase the EEPROM. Wait while the EEPROM is erased. When complete, the program prompts for the communications parameters.

3-4

Page 44

Batch and Spectrum One Terminal Setup

5. Baud Rate - the terminal displays: Comm Parameters Baud 4 9600

Scroll through the list using UpArrow or DownArrow. When the correct rate is displayed (38400 is recommended), press <ENTER>. 6. Data Bits - the terminal displays: Comm Parameters Data Bits 7

Press <7> (recommended) or <8> to specify data bits, or scroll through the list using UpArrow and DownArrow. Press <ENTER> when the correct value is displayed. Note: If 8 data bits is selected, the program selects "No parity" and skips the next step. 7. Parity - if 7 data bits is selected, the terminal displays: Comm Parameters Parity Odd

Press the first letter of a parity option (Even, Odd, None, Space, or Mark), or scroll using UpArrow and DownArrow and press <ENTER> when the correct value is displayed. 8. Flow Control - the terminal displays: Comm Parameters Flow Control None

Press the first letter of a flow control option (None, Xon/Xoff, or RTS/CTS), or scroll using UpArrow or DownArrow and press <ENTER> when the correct value is displayed.

3-5

Page 45

PDT 6800 Series Product Reference Guide

Starting Communications 1. The terminal is ready to receive the program from the host PC and displays: Comm Parameters Start? <ENT>

2. Press <ENTER> on the terminal. 3. Press <ENTER> on the host computer. The SENDHEX program begins transmitting the program image. When communications are established, the terminal displays: Program loader Receiving: XXXX where XXXX is the program segment address being transferred. 4. When the transmission is complete, the terminal displays: Program loader Status 0000

A status of 0000 (all zeros) indicates a successful transfer. Other status values indicate an error. These values are provided in Appendix C, Communications Status Codes. If you received an error, press CLEAR on the terminal to return to the Command Mode main menu.

Ending Communications To return to the Command Mode main menu: 1. Press CLEAR on the terminal. 2. Power down the terminal. 3. Detach any cables connected to the terminal. 4. Reboot the terminal using the appropriate cold boot sequence. Refer to Booting the Terminal on page 5-4.

3-6