Page 22
Chapter 2 Accessories Setup Introduction This chapter provides instructions for setting up the cradle, module, and PC adapter for charging the NiCd battery and communicating with a host, printer, or modem. Note: The Lithium Ion battery is charged in the UBC 2000 battery adapter p/n 21-32665-24. Refer to Chapter 6, Maintaining the Terminal for more information. The CRD 38/6865 cradle, CRD 38/6866 cradle, and CCM 38/6860 Charging and Communications Module provide RS-232 communication, charging, and storage for the PDT 6800 Series terminal. The PC adapter provides charging for the NiCd battery and communications for the terminal. Save the shipping container for storing or shipping the cradle, module, or PC adapter. Inspect all equipment for damage. If anything is damaged or missing, call your authorized customer support representative immediately.
2-1
Page 23
PDT 6800 Series Product Reference Guide
Required Parts Before attempting to mount or connect the cradles, verify that you have the following parts: CRD 38/6865 Single-Slot Cradle with Charging Slot: US Kit: 3865-110 ! International Kit: 3865-111 !
AC Power Supply: ! !
US:59915-00-00 International: 60507-00-00
CRD 38/6866 Four-Slot Cradle US Kit: 3866-100 ! International Kit: 3866-101 !
AC Power Supply ! !
US:60153-00-00 International: 60174-00-00
Null Modem Cable, DB 25 Male to DB 25 Female (p/n 25-19297-01)
Null Modem Cable, DB 25 Male to DB 25 Female (p/n 25-19297-01)
Null Modem Cable, DB25 Male to DB 9 Female (p/n 25-19299-01)
Null Modem Cable DB25 Male to DB 9 Female (p/n 25-19299-01) Chaining Interconnect Cable (p/n 60427-00-00)
Wall Mounting Kit (p/n 3866-000)
Two Wall Mounting Kits (p/n 3866-000) per 38/6866
Before attempting to mount or connect the Charging and Communications Module (CCM) 38/6860, verify that you have the following parts: Four-slot CCM Kit (includes power supply, mounting brackets, and hardware: ! !
US: 3860-100 International: 3860-101
AC Power Supply: US: 58690-00-00 ! International: 58690-01-00 !
Null Modem Cable ! !
DB-25 Female to DB-25 Female (p/n 59846-00-00) DB-25 Female to DB-9 Female (p/n 25-19298-01)
CCM Four-Slot Add-on Kit (includes CCM, coupling kit, and mounting brackets): !
2-2 p/n 3861-101
Page 24
Accessories Setup
Parts of the CRD 38/6865
Screw Hole Covers
Optical Connectors Battery Contacts Power Port Spare Battery Charging Slot
Charging LED
Serial Port
COMM LED
Figure 2-1. Parts of the CRD 38/6865
Parts of the CRD 38/6866 Screw Hole Covers
Power Port
Serial Port
Charging LED
COMM LED
Optical Connectors
Battery Contacts
Figure 2-2. Parts of the CRD 38/6866 2-3
Page 25
PDT 6800 Series Product Reference Guide
Wall Mounting the CRD 38/6865 The CRD 38/6865 can be wall-mounted on a wall bracket for convenience. To wall-mount the 38/6865: 1. Mark where you want the cradle positioned on the wall. 2. Using a fastener appropriate to the wall construction, insert and secure the fastener (Figure 2-3). Let the head protrude slightly.
Figure 2-3. Wall Mounting the 38/6865 3. Slide the bracket down over the head of the fastener. 4. Remove the black tape covers from the cradle screw holes ( Figure 2-4).
Figure 2-4. Removing theTape Covers
2-4
Page 26
Accessories Setup
5. Position the cradle on the bracket.
Figure 2-5. Secure Cradle to Bracket 6. Secure the cradle to the bracket using two #10 metal screws (Figure 2-5).
Wall Mounting the CRD 38/6866 The CRD 38/6866 can be wall-mounted on two mounting brackets. Follow the directions for Wall Mounting the CRD 38/6865 on page 2-4, using two brackets.
Table Mounting the CRD 38/6866 Note: Installing the suction cup feet is not mandatory but helps keep the cradle in place. 1. On the bottom of the cradle, thread each of the four suction cup feet into the screw holes.
2-5
Page 27
PDT 6800 Series Product Reference Guide
2. Wet the base of each suction cup and secure the cradle to a smooth tabletop by pushing firmly down on the cradle ( Figure 2-6).
Figure 2-6. Installing Suction Cups on the CRD 38/6866
Connecting Power Note: Connecting power to both CRD 38/6865 and CRD 38/6866 is the same. 1. Connect the power supply cord’s round plug to the power port on the left side of the cradle. 2. Connect the power supply’s AC plug to a standard electrical outlet.
2-6
Page 28
Accessories Setup
The green and red indicators light for 3 seconds, blink for 3 seconds, then go out.
CRD 38/6865
CRD 38/6866 Figure 2-7. Connecting Power to the CRD 38/6865 and CRD 38/6866
Connecting for Data Communications To connect the CRD 38/6865 or CRD 38/6866: 1. Be sure to unplug the cradle’s power supply before connecting the serial cables. 2. Turn off the PC. 3. Plug the RS-232 serial cable’s DB-25 connector in the cradle’s communication port (Figure 2-8). 4. Connect the cable’s other connector to the host computer’s serial (COMM) port.
2-7
Page 29
PDT 6800 Series Product Reference Guide
5. Reconnect the cradle’s power supply
CRD 38/6865
CRD 38/6866 Figure 2-8. Connecting the CRD 38/6865 and CRD 38/6866 for Communications with Computer, Printer, or Modem
2-8
Page 30
Accessories Setup
Connecting the CRD 38/6865 Internal Modem
RJ-11 Port
Figure 2-9. RJ-11 Internal Modem Connection Some cradles use an optional internal modem that communicates at rates of up to 14,400 bps (with v.32 bit data compression). It can be connected directly to a telephone line through the RJ-11 port shown in Figure 2-9. Note: The four-slot cradle does not have an internal modem. To connect the internal modem: 1. Connect the phone cord into the RJ-11 port on the back of the cradle. 2. Connect the other end of the phone cord into the wall phone jack.
Caution When connecting the internal modem to the phone line, always connect the phone line to the cradle first, then to the wall phone jack. When removing the connection, always remove the telephone line from the wall phone jack, then remove from the cradle. There are specific firmware settings which are used to configure the modem’s hardware and software for proper operation and regulatory compliance. The terminal’s application can control these settings and enable you to view and amend the settings for country/region, pulse/tone dialing, or repeat dial timing. Incorrectly defining these settings can lead to illegal use of the modem and can create unreliable operation. The application developer should consult the Series 3000 Application Programmer’s Reference Manual for correct settings.
2-9