Appendix E Boot-Up Quick Reference Introduction Table E-1 and Table E-2 list the boot procedures for the 35 and 46-key keyboards.
Table E-1. 35-Key Boot Procedures Boot Type
Key Sequence
Used For
Results
Power On
PWR, or Trigger, or Applying power remove terminal from cradle
Returns terminal to where it was when it was turned off.
Warm Boot
<F> <J> <PWR>
Choosing a program that resides in NVM.
Cold Boot
<SPACE> <FUNC> Up Arrow <PWR>
Resetting BIOS and Erases and recreates RAM disk. Only data in NVM is retained. the operating system.
Command Mode Start
<BKSP> <SHIFT> <PWR>
Entering command Takes terminal to beginning of mode for Self Test command mode. The first time you or communication turn the terminal on or after the terminal has been stored without batteries, acts the same as a Cold Boot (resets BIOS, loses contents of RAM).
If system software is present, returns terminal to DOS. Otherwise, returns terminal to command mode. Retains contents of RAM.
E-1
Page 105
PDT 6800 Series Product Reference Guide
Table E-2. 46-Key Boot Procedures Boot Type
Key Sequence
Used For
Results
Power On
PWR, or Trigger, or Applying power remove terminal from cradle
Warm Boot
<4> <5> <PWR>
Choosing a program that resides in NVM.
Cold Boot
<A> <B> <D> <PWR>
Resetting BIOS and Erases and recreates RAM disk. Only data in NVM is retained. the operating system.
Command Mode Start
<F> <I> <PWR>
Entering command Takes terminal to beginning of mode for Self Test command mode. The first time you or communication turn the terminal on or after the terminal has been stored without batteries, acts the same as a Cold Boot (resets BIOS, loses contents of RAM).
E-2
Returns terminal to where it was when it was turned off. If system software is present, returns terminal to DOS. Otherwise, returns terminal to command mode. Retains contents of RAM.
Page 106
Appendix F 2D Scanner Drivers and Applications Introduction The PDT 6800 Series terminal uses additional scanner drivers and applications to scan 2D bar codes. This chapter covers the following: !
Using scn2dssi.exe
!
Output messages
!
Application development
!
Application Notes
!
New APIs
!
New API definitions
!
Label Type definition for 2D scanner driver
!
SCN2DSSI scanner driver default parameters
!
Using bldscn2D.exe
!
Code type menus
!
Parameter menus.
Using Scn2dssi.exe Usage !
Scn2dssi.exe: Load the driver
!
Scn2dssi.exe -o: Overwrite the previous driver F-1
Page 107
PDT 6800 Series Product Reference Guide
!
Scn2dssi.exe -r: Remove the current driver
Output Messages Table F-1. Output Messages Screen 0:NB2DSSIA 1.03 PDF DRIVER LOADED CRC Checksum:0x1949 NEW INTB6 INSTALLED
Description The driver is successfully loaded. The driver version string is NB2DSSIA; major revision 1.0, minor revision 0.3. The checksum is 0x1949 (checksum will be different based on the version number) with decoder version string of NBRWCAAE.
decoder: NBRWCAAE ||||||||||||| 0:NB2DSSIA 1.03 PDF DRIVER LOADED CRC Checksum:0x1949 Re-Install Driver
The driver is successfully loaded. The driver version string is NB2DSSIA; major revision 1.0, minor revision 0.3. The checksum is 0x1949 (checksum will be different based on the version number) with decoder version string of NBRWCAAE.
NEW INTB6 INSTALLED decoder: NBRWCAAE ||||||||||||| 0:NB2DSSIA 1.03 PDF DRIVER LOADED CRC Checksum:0x1949 NEW INTB6 REMOVED
The driver is successfully loaded. The driver version string is NB2DSSIA; major revision 1.0, minor revision 0.3. The checksum is 0x1949 (checksum will be different based on the version number).
Driver Removed
Application Development The driver works with the standard Serial 3000 applications such as scan.exe. To use new APIs (ioctl functions), the urm.gt and urm.gd files must be updated.
F-2
Page 108
2D Scanner Drivers and Applications
Application Notes With composite codes enabled, you will experience a delay decoding UPC/EAN bar codes.
New APIs Table F-2 lists new APIs for scn2dssi.exe. Refer to scan1d2d.c for information on how to use these functions. Table F-2. APIs Function ConsIoctlGetExtDecoders (0x1B) ConsIoctlSetExtDecoders (0x19)
Length ConsIoctlGetExtDecodersLen ConsIoctlSetExtDecodersLen
Structure struct ExtDecoders_S { BYTE Bookland; BYTE EAN128; BYTE ISBT128; BYTE CouponCode; BYTE C39Trioptic; BYTE TLC39; BYTE RSS_14; BYTE RSS_Limited; BYTE RSS_Expanded; BYTE CompositeAB; + BYTE CompositeC; + BYTE Code128_Emulation; * BYTE MicroPDF; };
F-3
Page 109
PDT 6800 Series Product Reference Guide
Table F-2. APIs (Continued) Function
Length
Structure
ConsIoctlGetExtDecoderParms (0x1C) ConsIoctlSetExtDecoderParms (0x1A)
ConsIoctlGetExtDecoderParms Len ConsIoctlSetExtDecoderParms Len struct ExtDecoderParms_S { BYTE linear_security_level; BYTE linear_supp_enabled;BYTE code39_xmit_chkdgt; BYTE xmit_i25_chkdgt; BYTE msi_chkdgt_scheme; BYTE check_i25_chkdgt; BYTE random_weight_chkdgt; BYTE tri39_red_enabled; BYTE cvtEAN8_2_EAN13; BYTE cvtI25_2_EAN13; BYTE cvtC39_2_C32; BYTE C32Prefix; BYTE EnableC128Perf; BYTE C128PerfLvl; BYTE EnableC39Perf; BYTE C39PerfLvl; BYTE updf_performance; BYTE UPC_Composite; };
ConsIoctlGetScanOptions (0x1D) ConsIoctlSetScanOptions (0x1B)
ConsIoctlGetScanOptionsLen ConsIoctlSetScanOptionsLen struct ScanOptions_S { BYTE laser_on_time; BYTE aim_time; BYTE scan_mode; BYTE aim_mode; };
F-4
Page 110
2D Scanner Drivers and Applications
Table F-2. APIs (Continued) Function ConsIoctlGetMacroPDF 0x1C ConsIoctlSetMacroPDF 0x1A
Length ConsIoctlGetMacroPDFLen ConsIoctlSetMacroPDFLen
Structure struct MacroPDF_S { byte xmit_file_name; byte xmit_block_count; byte xmit_time_stamp; byte xmit_sender; byte xmit_addressee; byte xmit_csum; byte xmit_file_size; byte xmit_header; byte xmit_marker; };
ConsIoctlGetMacroPDFAuxData (0x1E) ConsIoctlGetMacroPDFAuxDa struct taLen MacroPDFAuxData_S { WORD SegmentIndex; WORD SegmentCount; CHAR FileId[256]; time_t Time_stamp; WORD FileSize; WORD CheckSum; CHAR FileName[256]; CHAR Sender[256]; CHAR Addressee[256]; }; ++ ConsIoctlGetVersion (0x1F)
ConsIoctlGetVersionLen struct Version_S { BYTE Major; BYTE Minor; BYTE Scannerver[20]; BYTE Decoderver[20]; };
F-5
Page 111
PDT 6800 Series Product Reference Guide
Table F-2. APIs (Continued) Function
Length
ConsIoctlGetMultiPacketStatus (0x20)
Structure
ConsIoctlGetMultiPacketStatus struct MultiPacketStatus_S Len { BYTE NumPacketsLeft; };
* Code128 Emulation is not supported in current release, but will be supported in future releases. + When Composite AB/C is enabled, the following barcode types are automatically enabled regardless of their status (EAN-128, EAN-13, EAN-8, RSS Expanded, RSS Limited, RSS-14, UPC-A, and UPCE). If driver-enabled barcode type is scanned, the driver WILL NOT send the data to application. ++ For MacroPDF, the driver returns MacroPDF barcode type to the application along with the main block. An application can then call ConsIoctlGetMacroPDFAuxData to retrieve the control block information. MacroPDFAuxData structure contains the last scanned and decoded MacroPDF control block. If MacroPDF has never been scanned, the field will contain 0, or NULL.
New API Definitions Get/Set Extended Decoders ConsIoctlGetExtDecoders command returns the status of the additional supported decoders in the terminal and uses ConsIoctlSetExtDecoders command to enable or disable the additional decoders supported in the terminal. Table F-3. Get/Set Extended Decoders Field
F-6
Size
Value/Description
Subcommand Number
BYTE
27 = Get, 25 = Set
Error Code
BYTE
Not Used
Bookland*
BYTE
0 = Disable, 1 = Enable
EAN128
BYTE
0 = Disable, 1 = Enable
ISBT128
BYTE
0 = Disable, 1 = Enable
CouponCode* *
BYTE
0 = Disable, 1 = Enable
C39Trioptic ***
BYTE
0 = Disable, 1 = Enable
TLC39
BYTE
0 = Disable, 1 = Enable
RSS_14
BYTE
0 = Disable, 1 = Enable
Page 112
2D Scanner Drivers and Applications
Table F-3. Get/Set Extended Decoders (Continued) Field
Size
Value/Description
RSS_Limited
BYTE
0 = Disable, 1 = Enable
RSS_Expanded
BYTE
0 = Disable, 1 = Enable
CompositeAB +
BYTE
0 = Disable, 1 = Enable
CompositeC +
BYTE
0 = Disable, 1 = Enable
Code128_Emulation ++
BYTE
0 = Disable, 1 = Enable
MicroPDF
BYTE
0 = Disable, 1 = Enable
* Bookland: User must enable UPC-A and/or EAN13 for Bookland. ** CouponCode: When enabled, it decodes UPC-A, UPC-A with 2 supplemental, UPC-A with 5 supplemental, and UPC-A/EAN-128 barcode codes. User must enable UPC-A, EAN-13, and EAN-128. ***C39Trioptic: Trioptic Code39 symbols always contain six characters. Trioptic Code39 and Code39 Full ASCII cannot be enabled simultaneously. + Composite AB: When enabled, the following barcode types are automatically enabled regardless of their status (EAN-128, EAN-13, EAN-8, RSS Expanded, RSS Limited, RSS-14, UPC-A, and UPCE). If driver-enabled barcode type is scanned, the driver will not send the data to application. + Composite C: When enabled, EAN-128 will be automatically enabled. If driver-enabled barcode type is scanned, the driver will not send the data to application. ++ Code128 Emulation is not supported in current release. It will be supported in future release.
Get/Set Extended Decoder Parameters Uses ConsIoctlGetExtDecoderParms or ConsIoctlSetExtDecoderParms to get or set the extended parameters. Table F-4. Get/Set Extended Decoder Parameters Field
Size
Value/Desciption
Subcommand Number
BYTE
28 = Get, 26 = Set
Error Code
BYTE
Not Used
F-7
Page 113
PDT 6800 Series Product Reference Guide
Table F-4. Get/Set Extended Decoder Parameters (Continued) Field
F-8
Size
Value/Desciption linear_security_level
BYTE
1 = Level 1, 2 = Level 2, 3 = Level 3, 4 = Level 4 linear_supp_enabled
BYTE
0 = Disable, 1 = Enable code39_xmit_chkdgt
BYTE
0 = Disable, 1 = Enable xmit_i25_chkdgt
BYTE
0 = Disable, 1 = Enable msi_chkdgt_scheme
BYTE
0 = Mod11/Mod10, 1 = Mod10/Mod10 check_i25_chkdgt
BYTE
0 = Disable 1 = USS check digit 2 = OPCC check digit random_weight_chkdgt
BYTE
0 = disable 1 = use four digit method 2 = use five digit method tri39_red_enabled
BYTE
0 = Disable, 1 = Enable cvtEAN8_2_EAN13
BYTE
0 = Type is EAN-8 1 = Type is EAN-13 cvtI25_2_EAN13
BYTE
0 = Disable, 1 = Enable cvtC39_2_C32
BYTE
0 = Disable, 1 = Enable
C32Prefix
BYTE
0 = Disable, 1 = Enable
EnableC128Perf
BYTE
0 = Disable, 1 = Enable
C128PerfLvl
BYTE
1 = Level 1, 2 = Level 2, 3 = Level 3
EnableC39Perf
BYTE
0 = Disable, 1 = Enable
C39PerfLvl
BYTE
1 = Level 1, 2 = Level 2, 3 = Level 3 updf_performance
BYTE
0 – 9; Level 0 to Level 9
UPC_Composite
BYTE
0 = UPC is never linked 1 = UPC always linked 2 = AutoD UPC linkage