3. Ensure that the scan beam crosses all bars and spaces on the bar code symbol, as shown below:
Right
Wrong
Hold the scanner farther away for larger symbols, and closer for symbols with bars that are close together. Long-range versions support a two-level scan trigger. The first, narrow beam is for aiming, and the second beam decodes the label. 4. The LED turns from red to green for successful decodes. The 68XX may also beep.
Aiming: Hold at an Angle Do not hold the 68XX’s scan window directly over the bar code. Laser light reflecting directly back into the scan window from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone”.
9
Page 12
6 8 X X
S e r i e s
You can tilt the 68XX up to 55° forward or back and achieve a successful decode. Practice quickly shows what tolerances to work within.
Performing Communications Communicating with a Host The 68XX communicates with a host through the CCM 38/6860, CRD 38/6865, CRD 38/6866, or PC Adapter. For information on setting up the CCM, cradles, or PC Adapter, refer to the PDT 6800 Series Product Reference Guide or the Quick Reference Guide provided with each unit. To communicate with a host: 1. Set up the cradle(s) or PC Adapter as described in the PDT 6800 Series Product Reference Guide or Quick Reference Guide for the device. 2. Place the 68XX’s base in the cradle. Press the top of the 68XX against the cradle back until it is firmly seated.
10
Page 13
Q u i c k
R e f e r e n c e
The Status LED lights solid green when the 68XX is securely placed in the cradle.
3. Start the communications program on the host and the 68XX. Caution:
Do NOT remove the 68XX while the cradle’s red COMM LED is blinking.
11
Page 14
6 8 X X
S e r i e s
Communicating with a Printer The 68XX communicates with a printer through the printer interface module (PIM). To connect the 68XX to the printer: 1. Attach the PIM’s optical connector to the 68XX’s port by inserting the clips on the connector in the slots on either side of the port. Clips
PIM Optical Connector
Slots
68XX’s Optical Port
2. Plug the PIM’s DB-9 connector in the printer’s port. 3. Power the printer and 68XX on. Communicating in a RF Network The PDT 6810 operates in a Symbol Spectrum One RF network; the PDT 684X operates in a Symbol Spectrum24 RF network. The Status LED indicates the state of the terminal’s connection to the RF network: Off indicates that the radio is working and associated with an access point (Spectrum24) or base station (Spectrum One).
Flashes red once per second to indicate that the radio is out of range or not associated with an access point or base station.
Refer to the documentation for the Spectrum One or Spectrum24 network for more information on operating the PDT 68XX in that RF environment.
12
Page 15
Q u i c k
R e f e r e n c e
Switching from 802.11 to Spring RF Protocol (PDT 6842) Note:
The terminal boots up with the 802.11 RF protocol. Perform the following procedure to switch to the Spring RF protocol.
1. Boot up the terminal. The following prompt displays: SOFTWARE UPDATE Update?[y/n]:
2. Within four seconds, type the letter “y”. If you do not type the letter “y” within four seconds, the terminal boots up with the 802.11 RF protocol. The next prompt displays: RF PROTOCOL UPDATE OPPORTUNITY Update RF protocol [y/n]:
3. Within ten seconds, type the letter “y”. If you do not type the letter “y” within ten seconds, the terminal boots up with the 802.11 RF protocol. The next prompt displays: RF Protocol Currently 802.11 1. Abort update 2. Make pre-802.11 3. Make 802.11 Select[1,2,3]:
4. Select 2 to boot up with the Spring RF protocol. 13
Page 16
6 8 X X
S e r i e s
The next prompt displays: Enter password
→
5. Enter the password RFPROT, then press the ENTER key. The terminal continues to boot up. If a compatibility problem exists, the terminal pauses with an error message. Contact your System Administrator.
Troubleshooting Symptom 68XX does not power on.
Possible Cause
Action
Battery is not installed.
Verify that the 68XX has power from a battery.
Battery is not charged.
NiCd battery - Charge the battery in the terminal, or remove the battery and charge in the spare battery charging slot on the CCM 38/6860 or CRD 38/6866. Lithium Ion - Remove the battery from the terminal and charge in a UBC 2000 adapter.
Low Battery message.
The main battery pack is running low.
NiCd battery - Place the 68XX in a cradle and recharge the battery. OR Power the 68XX off and replace the battery.
14
Page 17
Q u i c k
R e f e r e n c e
Symptom
Possible Cause
Action
Low Battery message. (continued)
The main battery pack is running low. (continued)
Lithium Ion battery - Remove the battery from the 68XX and charge in a UBC 2000 adapter. OR Power the 68XX off and replace the battery.
Battery is dead.
Battery not replaced after receiving Low Battery message.
Replace the battery.
Cannot see characters on display.
68XX not powered on.
Press the PWR key.
Battery pack is missing or dead.
Replace or recharge the battery pack.
Contrast not adjusted properly.
Refer to page 7 for the key sequence.
The bar code is unreadable.
Verify that the bar code is not defective, e.g., smudged or dirty.
Scan window is dirty.
Clean scan window with lens tissues for use with eyeglasses. Do NOT use tissues with lotion.
Double Key error message displays.
Two or more keys were pressed at the same time.
Press keys in sequence.
68XX does not respond when keys are pressed.
Application was not successfully downloaded.
Ask System Administrator to repeat application download.
Scanner does not decode a bar code.
15
Page 18
6 8 X X
Ss
16 e
Page 19
G u i d e u t i l i s a t e u r
Présentation Le 68XX est un ordinateur portable robuste et résistant aux intempéries qui réunit les caractéristiques suivantes : • • • • • • •
Architecture PC standard (architecture 16 bits 8088) Compatible DR-DOS Ecran 16 lignes de 21 caractères Saisie à partir du clavier alphanumérique à 35 touches ou à 46 touches Lecteur intégré Batteries lithium-ion et NiCd rechargeables Communications batch ou via le réseau radio (avec antenne interne) : - Réseau radio Spectrum One® (681X) - Réseau radio Spectrum24® (684X).
A propos de ce guide Ce guide fournit à l'utilisateur des instructions pour réaliser les opérations suivantes : • • • • • • • • •
Mise en place/extraction de la batterie Chargement de la batterie Activation/désactivation du 68XX Réglage du contraste de l’écran Activation/désactivation du rétroéclairage Utilisation du clavier Utilisation du lecteur intégré Etablissement de communications Dépannage du 68XX.
17
Page 20
S é r i e d e s
6 8 X X
Composants du 68XX Témoin du Scan LED lecteur Ecran Display Bouton “Power” (touche de mise PWR Key sous tension) Témoin Status LED d’état tus
Sta
+
- -
=
Clavier Keyboard
Fenêtre de Scan Window lecture Gâchette de Scan Trigger lecture Battery Pack de Pack batterie Connecteurs optiques
Plots de chargement des batteries
Compartiment de batterie Déverrouillage de batterie Verrou de batterie
Sangle