Page 61
Series 3300 System Administration Manual
Startup Failures If a cold boot does not successfully start the application, either the application, the system software, or the system is malfunctioning. If you can boot the system to command mode, try the following: •
Use the Program Loader function to download a new version of the system software to NVM. This procedure is described in Chapter 2.
•
Use the Self Test function to check if the system hardware is operating properly. This procedure is described later in this chapter. After downloading new system software, warm boot the 3300.
Boot Failure Messages During a cold boot, the system briefly displays a status line for each driver as it loads in the format: 0: Driver
#.##
The line shows a status value, usually 0, followed by the name and version number of the driver. If the system halts at one of these lines and displays a status value other than 0, the displayed device driver failed to load properly. If such a failure occurs, the driver may need to be reloaded. If this does not solve the problem, call your authorized Symbol representative or Technical Support Services.
4-4
Page 62
Error Recovery and Troubleshooting
Self Test Function The 3300 includes a series of self tests which can be run to verify the operation of terminal hardware components. You should run the self test if you suspect a problem with the hardware. Except for testing the keyboard, no operator input is necessary after a test screen is selected.
Running the Self Test The Self Test function is selected from the command mode menu. Boot to command mode: 56-key: 35-key:
On/Off and A + D On/Off and Bksp + Shift
When the Command Mode screen is displayed, use the up or down arrow key to scroll through the options until Self Test is displayed, and press Enter.
Self Test Summaries The Self Test is divided into five functions or screens: •
Config Screen 1 - Reports the terminal type and version, time, date, main and backup battery condition, current power source, and status of the serial ports.
•
Config Screen 2 - Reports information on the keyboard and display. If a laser scanner is attached, the test reports if the trigger is pulled or not. If a wand scanner is attached, the test reports whether the wand is scanning black or white.
•
Memory Screen - Tests ROM, RAM, and EMS (Expanded) memory, and reports the amount of RAM and EMS.
•
Fill Screen - Fills the entire screen with a test pattern, so the operator can visually verify that the entire screen displays.
•
Set RTC Screen - Allows the operator to set the time and date settings of the real-time clock. 4-5
Page 63
Series 3300 System Administration Manual
Keyboard Test While the Config Screen 1 results are displayed, you can test any keys except Clear and On/Off. When you press a key, the corresponding key code is displayed on the top row to the right of the test name. Tables 4-3 and 4-4 list the codes for each key. Table 4 - 3 56-key Keyboard Test Codes
4-6
Key
Scan Code
Key
Scan Code
F1/F6 F2/F7 F3/F8 F4/F9 F5/F10 A B C D E F G H/help I J K L/lamp M/menu N O P Q R S/send T U/+ V/-
00 01 02 03 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
W/(mult) X/(divide) Y Z CapsLock Func Ctrl Shift 7 8 9 4 5 6 Space/dark Up arrow Backspace/light 1 2 3 left arrow down arrow right arrow _/No 0 ./Yes Enter/=
28 29 30 31 32 33 34 35 36 37 38 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
Page 64
Error Recovery and Troubleshooting
Table 4 - 4 35-key Keyboard Test Codes Key Space Alpha Shift Control Func [/A ]/B '/C =/D */E / /F ,/G \/H ;/I left arrow/J right arrow/K up arrow/L
Scan Code 00 01 02 03 04 05 06 07 08 10 11 12 13 14 15 16 17
Key down arrow/ M +/N 7/O 8/P 9/Q Clear 4/R 5/S 6/T Backspace 1/U 2/V 3/W ./X 0/Y _/Z Enter
Scan Code 18 19 20 21 22 (clear) 24 25 26 27 28 29 30 31 32 33 34
Exiting Self Test The test loop continues, updating the time and battery status and processing keystrokes, until you press Clear to end the test. When you press Clear, the display returns to the command mode function menu.
4-7
Page 65
Series 3300 System Administration Manual
Scanning Problems Bar code labels that do not meet established industry specifications may not scan successfully. These labels may include: •
Smudged labels
•
Very dark or very light labels
•
Highly reflective surfaces or coatings
•
Poor color contrast.
The following may also cause unsuccessful scans: •
Moving the contact wand scanner too quickly
•
Moving the contact wand scanner too slowly
•
Moving the contact wand scanner at an uneven speed
•
Moving the scanner diagonally across the bar code.
4-8
Page 66
Error Recovery and Troubleshooting
Memory Transfer Program The Series 3300 Command Mode functions include a memory transfer utility. Memory transfer is used primarily for program troubleshooting. This may be required, for example, if the application program hangs. Analysis of the program is performed by a programmer using tools described in the Series 3000 Application Programmer’s Guide. The memory transfer function transfers data from the Series 3300 to the host PC. You may select to transfer either all or a range of memory. The following procedure describes the 3300 side of the transaction only. The PC side of the transaction is determined by the communication software used.
Running Memory Transfer Memory transfer is conducted using communications over a direct connection between the 3300 and the host computer, using a null modem cable. The cable has a male DB-25 connector at one end and a female DE-9 connector at the other end. Warning This procedure is not approved for, and should not be performed in, potentially hazardous environments. Caution Always turn off the 3300 before attaching or removing cables or adapters. 1. Turn OFF both the 3300 and the host. 2. Attach the null modem cable. Attach the 25-pin connector to the 3300 and the 9-pin connector to the host computer. 3. Turn ON the host and start the communication program. Set up the communication parameters to match the 3300. Typical parameters are: 38400 bps 7 bit data Odd parity Xon/Xoff flow control 4-9
Page 67
Series 3300 System Administration Manual
4. Boot the 3300 to command mode (refer to Chapter 3): 56-key: On/Off and A+D 35-key: On/Off and Bksp + Shift 5. Select the Memory Transfer function from the command mode menu. Use the Up or Down cursor keys to scroll through the command mode options until Memory Transfer is displayed, and press Enter. 6. Select the range of memory to transfer by pressing the first letter of the desired range (All, Range, or None), or use the up or down arrow key, and press Enter. If you select All, the program skips to the summary screen (step 10). 7. If you select Range, the screen displays: RAM Use Arrow Keys Start End 00000 9FFFF Specify a range of RAM by setting the Start and End addresses. •
Use the right and left arrow keys to move the cursor to the digit that you want to change.
•
Use the up and down arrow keys to change the values.
When you have entered a range, press Enter. 8. Specify a range of NVM to transfer. Choose All or None. 9. If the system has EMS installed, it prompts for the range to transfer; otherwise, the program skips this screen: EMS Use arrow keys Start End 4 - 10
Page 68
Error Recovery and Troubleshooting
The range is specified in page numbers (16KB per page). Use the right and left arrow keys to move between the Start and End values. Use the up and down arrow keys to change the page number value. When you have set the range, press Enter. 10. The terminal displays the selected ranges for verification, for example: RAM 0000 3FFF NVM C839 DFFF EMS None Correct? If the values are correct, press Enter. If the values are not correct, press Clear to clear the fields, and then select new values. 11. Specify the baud rate. Use the up and down arrows scroll through the list of baud rates until the correct rate is displayed, and press Enter. (Flow control may be necessary at 38400 bps and higher.) 12. Specify the data bits. Press 7 or 8, or use the up and down arrows to display 7 or 8, and press Enter. If you select 8 data bits, the program selects No parity and skips the next screen. 13. Specify parity type. If you selected 7 data bits, the 3300 prompts for the parity. Use the up and down arrows to display a parity option, or press the first letter of a parity option (Even, Odd, None, Space, or Mark), and press Enter. 14. Set flow control. Use the up and down arrows to display the flow control options, or you may press the first letter of an option (None, Xon/Xoff, or RTS/ CTS). Then press Enter.
4 - 11
Page 69
Series 3300 System Administration Manual
15. The system is now ready to send the data to the host PC. The 3300 displays: Comm Parameters Start? <ENT> Make sure the host is ready to received data, and press Enter on the 3300. While data is being transferred, the 3300 displays a report of the 1 KB range being transferred: Memory Transfer Sending: XXXX The display is updated for every 1024 bytes (1 KB) of memory. 16. When the transmission has completed or aborted, the transmission status screen is displayed: Memory Transfer Status 0000 A Status of 0000 (all zeros) indicates that the transfer was successful. Other status values are described in Appendix D.
Ending Communications To return to the Command Mode main menu, press Clear. Then take whatever corrective action is necessary, and reboot the terminal.
4 - 12
Page 70
Appendix A
Port Pin-Outs This Appendix provides reference information for Series 3300 ports and mappings for a null modem cable.
Scanner Port (DE-9) The scanner port is located at the top of the 3300, under a protective rubber boot. The pin descriptions are listed in Table A-1. Table A - 1 Scanner Port Pin Descriptions Pin Name Function 1 LASERDIR Laser direction indicator* 2 BWD Black/white data 3 WANDLED Wand L.E.D. control 4 no connection 5 LASERTRIGN Laser trigger not 6 WANDELC Wand electronics enable 7 GROUND Logic/power ground 8 GROUND Logic/power ground 9 WANDPWR Wand Power (+5V) * Must be grounded on contact wand scanners
Direction input input output input output output
A-1