Page 31

Series 3300 System Adminstration Manual

Charging the NiCad Battery Pack The NiCad battery pack can be recharged while it is in or out of the system. To charge the battery pack external to the system, use the Symbol Universal Battery Charger. Up to four NiCad packs can be charged at one time using this charger. If the system is equipped with the optical end cap, recharging begins when the 3300 is placed in a properly set up cradle. Refer to the cradle documentation for additional information. To charge the NiCad batteries in the 3300 using the 12V adapter, do the following (refer to Figure 2-2): Warning This procedure is not approved for and should not be performed in potentially hazardous environments. 1. Turn the system off. 2. Unlock and remove the end cap and locate the battery charger port. 3. Plug the charger end of the adapter into a wall socket. 4. Plug the cable end into the 3300's battery charger port. 5. After 12 to 16 hours, disconnect the charger cable from the system and the wall outlet. The 3300 may be used while the battery is being charged.

2-8

Page 32

Maintaining the Series 3300

Figure 2 - 2 Charging NiCad Pack Using Adapter

Battery Charging Tips For maximum capacity and battery life, follow these helpful hints: •

Charge at temperatures between 0oC and 45oC (32oF to 113oF).

•

Recharge as soon as you see the "Low Battery" message.

•

Recharge primary batteries after storage.

•

If you find that your battery pack begins to need recharging more often, let it discharge as completely as possible, then recharge it for at least 16 but not more than 24 hours. Undercharging and overcharging can shorten the life of your battery pack.

2-9

Page 33

Series 3300 System Adminstration Manual

Lithium Backup Batteries The Series 3300 use two CR1/3N cylindrical lithium batteries (product number 3027-160) as backup power. The backup batteries provide enough power to maintain the contents of memory (RAM, including the RAM disk) for approximately 300 to 400 hours. Depending on the system configuration, the "Dead lithium" message may display when the backup battery power is low.

Replacing Backup Batteries It is recommended that you upload any data in memory to the host computer before replacing the backup batteries. To retain programs and data in RAM while replacing the backup batteries, it is necessary to have main power applied. If the 3300 has the standard end cap (nonoptical), you can plug in the 12 volt adapter to provide power. Otherwise, it is necessary to have charged main batteries in place. Caution When both main and backup power are removed at the same time, RAM contents are lost. To replace the lithium batteries, do the following: Warning This procedure is not approved for and should not be performed in potentially hazardous environments. 1. Unload any data, using methods provided by the application program. 2. Turn the system off. 3. Remove the primary battery pack, as described earlier in this chapter.

2 - 10

Page 34

Maintaining the Series 3300

4. Locate the lithium backup batteries next to the battery pack compartment (Figure 2-3). Remove the backup batteries by pulling the ribbon handles.

Back of Terminal Lithium Batteries

Figure 2 - 3 Location of Lithium Batteries Caution Dispose of dead batteries in accordance with local hazardous material laws. 5. Insert the new lithium backup batteries into the placement socket with the ribbon handle on the top. 6. The lithium batteries must be installed with the + and - signs on the battery on the same side as the + and - signs inside the backup battery compartment. The batteries must be installed with correct polarity for the system to operate. 7. Reinsert the primary battery pack and close the battery compartment. If necessary, you can now download a new copy of the program.

2 - 11

Page 35

Series 3300 System Adminstration Manual

Initializing the 3300 Before the 3300 is ready to use, it must be initialized by loading the application program. The program is stored in the terminal in non-volatile memory (NVM, also called the application EEPROM). The program is transferred from a host computer to the terminal over a communications line provided by either a null modem cable or a cradle. The procedure described here uses the sendhex command on the PC and the Program Loader function on the terminal. For details on the sendhex command, refer to the Series 3000 Application Programmer's Manual. Other software may be used in place of sendhex.

Cancelling Communication At any time during the communication session, you can cancel communications by pressing Clear on the 3300. The session stops immediately.

Communication Parameters The communication parameters specified on the host and the 3300 must match. Typical parameters are: 38400 bps 7 bit data Odd parity Xon/Xoff flow control

Loading the Program A direct connection between the Series 3300 and the host PC is made with a null modem cable (Symbol product number 3057-F03). The cable has a male DB-25 connector at one end and a female DE-9 connector at the other end. To download the program, do the following:

2 - 12

Page 36

Maintaining the Series 3300

.

Figure 2 - 4 Communication and Charger Connections Warning This procedure is not approved for and should not be performed in potentially hazardous environments. 1. Power OFF the 3300 and host PC. 2. Attach the male connector end to the 3300 and the female end to the host's serial port (Figure 2-4). 3. Power up the PC and start the communication program. If you use the sendhex command with the null modem connected to COM2, enter: cd \ sendhex pgmname 38400 com2 Do not include the .hex extension on the program name. 2 - 13

Page 37

Series 3300 System Adminstration Manual

Once correctly started, sendhex displays a prompt to press Enter to begin communications. You will start communications later (step 11). Only the baud rate and comm port can be set by sendhex (defaults are 9600 bps and com1). Change these parameters as shown in the example. Other parameters are set to 7 data bits, odd parity, and Xon/Xoff flow control (version 3.0). Note Versions of sendhex earlier than 3.0 do not support flow control. If you use an earlier version and encounter communication errors, use a lower baud rate. 4. Boot the 3300 to command mode (refer to Chapter 3): 56-key: On/Off and A+D 35-key: On/Off and BkSp+Shift After booting, the terminal displays the function selector screen: COMMAND MODE Select function Self Test 5. Use the up or down cursor keys to scroll through the command mode options until "Program loader" is displayed, and press Enter. 6. The original contents of NVM (an EEPROM) must be erased before loading the new program. The terminal displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT> Note To cancel this operation, press Clear. Press Enter to erase the EEPROM. Wait while the EEPROM is erased. 2 - 14

Page 38

Maintaining the Series 3300

Once erasing the EEPROM is completed, the program prompts for the communications parameters. 7. Baud Rate. The baud rate screen is displayed: Comm Parameters Baud 4 9600 Use the up or down cursor key to scroll through the list of baud rates. When the correct rate is displayed (38400 is recommended), press Enter. 8. Data Bits. The data bits screen is displayed: Comm Parameters Data Bits 7 Press 7 (recommended) or 8 to specify the data bits, or use the up and down arrows. When the correct value is displayed, press Enter. Note If you select 8 data bits, the program selects "No parity" and skips the next step. 9. Parity. If you selected 7 data bits, the parity screen is displayed: Comm Parameters Parity Odd Press the first letter of a parity option (Even, Odd, None, Space, or Mark), or use the up and down arrows to display a parity option, and press Enter.

2 - 15

Page 39

Series 3300 System Adminstration Manual

10. Flow Control. The flow control screen is displayed: Comm Parameters Flow Control None Press the first letter of a flow control option (None, Xon/Xoff, or RTS/CRS), or use the up and down arrows to display a flow control option, and press Enter.

Starting Communications The 3300 is now ready to receive the program from the host PC. The 3300 displays: Comm Parameters Start? <ENT> 11. Press Enter on the 3300. The terminal waits a few seconds for the host PC to initiate communications. While waiting, the 3300 displays: Awaiting DSR 12. Press Enter on the host computer. Sendhex will begin transmitting the program image. When communications are established, the 3300 displays the following: Program loader Receiving: XXXX While the program is loading, the display shows the segment address currently being transferred (XXXX).

2 - 16

Page 40

Maintaining the Series 3300

13. When the transmission is complete, the 3300 displays a transmission status screen: Program loader Status 0000 A Status of 0000 (all zeros) indicates that the transfer was successful. Other status values are described Appendix C.

Ending Communications To return to the Command Mode main menu, press Clear on the 3300. Turn the terminal off and detach the communications cable. To start the software running, reboot the terminal using the cold boot sequence (refer to Chapter 3): 56-key: On/Off and Enter+F1+F4 35-key: On/Off and Space+Func+UpArrow

2 - 17